1.
OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.  相似文献   

2.
OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.  相似文献   

3.
Objectives: To compare number of cycles to failure for palmarodorsal 4‐point bending of a modified 5.5 mm broad locking compression plate (M5.5‐LCP) fixation with a 5.5 mm broad LCP (5.5‐LCP) fixation used to repair osteotomized equine third metacarpal (MC3) bones. Study Design: In vitro biomechanical testing. Animal Population: Adult equine cadaveric MC3 bones (n=6 pairs). Methods: An 8‐hole, M5.5‐LCP, obtained by having a 1.0 mm thickness removed from the bone contact portion of the 5.5‐LCP, was applied to the dorsal surface of 1 randomly selected MC3 from each pair, and an 8‐hole, 5.5‐LCP was applied dorsally to the contralateral bone from each pair using a combination of cortical and locking screws. Plates and screws were applied using standard ASIF techniques to MC3 bones with a mid‐diaphyseal osteotomy. MC3 constructs had palmarodorsal 4‐point bending cyclic fatigue testing. Mean cycles to failure for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results: Mean±SD cycles to failure of the M5.5‐LCP fixation (188,641±17,971) was significantly greater than that of the 5.5‐LCP fixation (166,497±15,539). Conclusion: M5.5‐LCP fixation was superior to 5.5‐LCP fixation of osteotomized equine MC3 bones in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance: This suggests that biological plate fixation is not the ideal choice for osteotomized equine MC3 bones.  相似文献   

4.
Objective— To compare monotonic biomechanical properties and fatigue life of a broad locking compression plate (LCP) fixation with a broad limited contact dynamic compression plate (LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population— Cadaveric adult equine MC3 bones (n=12 pairs). Methods— MC3 were divided into 3 groups (4 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 4.5 mm LCP was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm LC‐DCP) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment, under 4‐point bending, single cycle to failure, of the LCP fixation were significantly greater than those of the LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly greater for the LCP fixation compared with LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad LCP fixation compared with the LC‐DCP fixation. Conclusion— The 4.5 mm LCP was superior to the 4.5 mm LC‐DCP in resisting the static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for the repair of equine long bone fractures.  相似文献   

5.
OBJECTIVES: To compare biomechanical properties of a prototype 5.5 mm tapered shaft cortical screw (TSS) and 5.5 mm AO cortical screw for an equine third metacarpal dynamic compression plate (EM-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: Paired in vitro biomechanical testing of cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Adult equine cadaveric MC3 bones (n=12 pairs). METHODS: Twelve pairs of equine MC3 were divided into 3 groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of each, mid-diaphyseal osteotomized, MC3 pair. For each MC3 bone pair, 1 was randomly chosen to have the EM-DCP secured with four 5.5 mm TSS (2 screws proximal and distal to the osteotomy; TSS construct), two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws in the remaining holes. The control construct (AO construct) had four 5.5 mm AO cortical screws to secure the EM-DCP in the 2 holes proximal and distal to the osteotomy in the contralateral bone from each pair. The remaining holes of the EM-DCP were filled with two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws. All plates and screws were applied using standard AO/ASIF techniques. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the TSS construct were significantly greater (P<.00004 for yield and P<.00001 for failure loads) than those of the AO construct. Mean cycles to failure in 4-point bending of the TSS construct was significantly greater (P<.0002) than that of the AO construct. The mean yield load and composite rigidity in torsion of the TSS construct were significantly greater (P<.0039 and P<.00003, respectively) than that of the AO construct. CONCLUSION: The TSS construct provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: The results of this in vitro study support the conclusion that the EM-DCP fixation using the prototype 5.5 mm TSS is biomechanically superior to the EM-DCP fixation using 5.5 mm AO cortical screws for the stabilization of osteotomized equine MC3.  相似文献   

6.
Objectives: To compare the number of cycles to failure of 4.5 mm broad dynamic compression plates (DCP), 4.5 mm broad limited‐contact dynamic compression plates (4.5‐LC‐DCP), and 5.5 mm broad limited‐contact dynamic compression plates (5.5‐LC‐DCP) having a rough (denoted by a prefix R‐) versus a standard smooth contact surface for the fixation of osteotomized equine 3rd metacarpal (MC3) bones. Study Design: Experimental. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for comparison of (1) R‐DCP fixation with DCP fixation, (2) R‐4.5‐LC‐DCP fixation with 4.5‐LC‐DCP fixation, and (3) R‐5.5‐LC‐DCP fixation with 5.5‐LC‐DCP fixation to repair osteotomized equine MC3 bones under palmarodorsal 4‐point bending cyclic fatigue testing. For each group an 8‐hole plate with rough contact surface was applied to the dorsal surface of one randomly selected bone from each pair and a corresponding 8‐hole plate with smooth contact surface was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean number of cycles to failure for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results: Mean cycles to failure ± standard deviation was significantly greater for the R‐DCP fixation (230,025 ± 23,129) compared with the DCP fixation (103,451 ± 14,556), for the R‐4.5‐LC‐DCP fixation (99,237 ± 14,390) compared with the 4.5‐LC‐DCP fixation (46,464 ± 6325) and for the R‐5.5‐LC‐DCP fixation (65,113 ± 7796) compared with the 5.5‐LC‐DCP fixation (34,224 ± 3835). Conclusion: For the fixation of osteotomized MC3 bones, the constructs with plates having rough contact surface were superior to the corresponding constructs with plates having standard smooth contact surfaces in resisting cyclic fatigue under palmarodorsal 4‐point bending.  相似文献   

7.
Objectives: To compare the monotonic biomechanical properties and fatigue life of a 5.5‐mm‐broad locking compression plate (5.5 LCP) fixation with a 4.5‐mm‐broad locking compression plate (4.5 LCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. Study Design: In vitro biomechanical testing of paired cadaveric equine MC3 with a middiaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for (1) 4‐point bending single cycle to failure testing, (2) 4‐point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An 8‐hole, 5.5 LCP was applied to the dorsal surface of 1 randomly selected bone from each pair and an 8‐hole, 4.5 LCP was applied dorsally to the contralateral bone from each pair using a combination of cortical and locking screws. All plates and screws were applied using standard ASIF techniques. All MC3 bones had middiaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group with significance set at P<.05. Results: Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4‐point bending, single cycle to failure, of the 5.5 LCP fixation were significantly greater than those of the 4.5 LCP fixation. Mean cycles to failure in 4‐point bending of the 5.5 LCP fixation (170,535±19,166) was significantly greater than that of the 4.5 LCP fixation (129,629±14,054). Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad 5.5 LCP fixation compared with the 4.5 LCP fixation. In single cycle to failure under torsion, the mean±SD values for the 5.5 LCP and the 4.5 LCP fixation techniques, respectively, were: yield load, 151.4±19.6 and 97.6±12.1 N m; composite rigidity, 790.3±58.1 and 412.3±28.1 N m/rad; and failure load: 162.1±20.2 and 117.9±14.6 N m. Conclusion: The 5.5 LCP was superior to the 4.5 LCP in resisting static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance: These in vitro study results may provide information to aid in selection of an LCP for repair of equine long bone fractures.  相似文献   

8.
Objectives— To compare monotonic biomechanical properties and fatigue life of a 5.5 mm broad limited‐contact dynamic compression plate (5.5‐LC‐DCP) fixation with a 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Sample Population— Adult equine cadaveric MC3 bones (n=18 pair). Methods— MC3 were divided into 3 test groups (6 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 5.5 mm broad LC‐DCP (5.5‐LC‐DCP) was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) was applied dorsally to the contralateral bone from each pair. Plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t–test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment under 4‐point bending, single cycle to failure, of the 5.5‐LC‐DCP fixation were significantly greater (P<.024) than those of the 4.5‐LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly (P<.05) greater for the 4.5‐LC‐DCP fixation compared with the 5.5‐LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion for the 5.5‐LC‐DCP fixation was not significantly different (P>.05) than those with the 4.5‐LC‐DCP fixation. Conclusion— 5.5‐LC‐DCP fixation was superior to 4.5‐LC‐DCP fixation in resisting the static overload forces under palmarodorsal 4‐point bending. There was no significant difference between 5.5‐LC‐DCP fixation and 4.5‐LC‐DCP fixation in resisting static overload forces under torsion; however, the 5.5‐LC‐DCP offers significantly less stability (80% of that of the 4.5‐LC‐DCP) in cyclic fatigue testing. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for long bone fracture repair in horses.  相似文献   

9.
OBJECTIVE: To compare the mechanical properties of two stabilization methods for ostectomized equine third metacarpi (MC3): (1) an interlocking nail system and (2) two dynamic compression plates. Animal or Sample Population-Ten pairs of adult equine forelimbs intact from the midradius distally. METHODS: Ten pairs of equine MC3 were divided into two test groups (five pairs each): caudocranial four-point bending and torsion. Interlocking nails (6 hole, 13-mm diameter, 230-mm length) were placed in one randomly selected bone from each pair. Two dynamic compression plates one dorsally (12 hole, 4.5-mm broad) and one laterally (10 hole, 4.5-mm broad) were attached to the contralateral bone from each pair. All bones had 1 cm mid-diaphyseal ostectomies. Five construct pairs were tested in caudocranial four-point bending to determine stiffness and failure properties. The remaining five construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite, respectively, in four-point bending were: composite rigidity, 3,454+/-407.6 Nm/rad and 3,831+/-436.5 Nm/rad; yield bending moment, 276.4+/-40.17 Nm and 433.75+/-83.99 Nm; failure bending moment, 526.3+/-105.9 Nm and 636.2+/-27.77 Nm. There was no significant difference in the biomechanical values for bending between the two fixation methods. In torsion, mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite were: composite rigidity, 124.1+/-16.61 Nm/rad and 262.4+/-30.51 Nm/rad; gap stiffness, 222.3+/-47.32 Nm/rad and 1,557+/-320.9 Nm/rad; yield load, 94.77+/-7.822 Nm and 130.66+/-20.27 Nm, respectively. Composite rigidity, gap stiffness, and yield load for double plate fixation were significantly higher compared with interlocking nail fixation in torsion. CONCLUSIONS: No significant differences in biomechanical properties were identified between an interlocking nail and double plating techniques for stabilization of ostectomized equine MC3 in caudocranial four-point bending. Double plating fixation was superior to interlocking nail fixation in torsion.  相似文献   

10.
OBJECTIVE--To compare the mechanical properties of 2 interlocking-nail systems for fixation of ostectomized equine third metacarpi (MC3): (1) a standard interlocking nail with 2 parallel screws proximal and distal to a 1-cm ostectomy; and (2) a modified interlocking nail with 2 screws proximal and distal to a 1-cm ostectomy with the screws offset by 30 degrees. ANIMAL OR SAMPLE POPULATION--Twelve pairs of adult equine forelimbs intact from the midradius distally. METHODS--Twelve pairs of equine MC3 were divided into 2 test groups (6 pairs each): torsion and caudocranial 4-point bending. Standard interlocking nails (6-hole, 13-mm diameter, 230-mm length) were placed in 1 randomly selected bone from each pair. Modified interlocking nails (6-hole, 13-mm, 230-mm length, screw holes offset by 30 degrees) were placed in the contralateral bone from each pair. All bones had 1-cm mid-diaphyseal ostectomies. Six construct pairs were tested in caudocranial 4-point bending to determine stiffness and failure properties. The remaining 6 construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t test within each group. Significance was set at P <.05. RESULTS--Mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite, respectively, in 4-point bending were: composite rigidity, 3,119 +/- 334.5 Nm/rad (newton. meter/radian) and 3,185 +/- 401.2 Nm/rad; yield bending moment, 205.0 +/- 18.46 Nm and 186.7 +/- 6.17 Nm; and failure bending moment, 366.4 +/- 21.82 Nm and 378.1 +/- 20.41 Nm. There were no significant differences in the biomechanical values for bending between the 2 fixation methods. In torsion, mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite were: composite rigidity, 135.5 +/- 7.128 Nm/rad and 112.5 +/- 7.432 Nm/rad; gap stiffness, 207.6 +/- 10.57 Nm/rad and 181.7 +/- 12.89 Nm/rad; and yield load, 123.3 +/- 2.563 Nm and 107.5 +/- 8.353 Nm, respectively. Composite rigidity and gap stiffness for standard interlocking-nail fixations were significantly higher than the modified interlocking-nail fixation technique in torsion. Yield load had a tendency to be higher for the standard interlocking-nail fixation (P =.15). CONCLUSIONS--No significant differences in biomechanical properties were identified between a standard interlocking nail and one with the screw holes offset by 30 degrees in caudocranial 4-point bending. The standard interlocking nail was superior to the modified interlocking nail in torsional gap stiffness and composite rigidity. The torsional yield load also tended to be higher for the standard interlocking nail. CLINICAL RELEVANCE--The standard interlocking nail with parallel screw holes is superior to a modified interlocking nail with the screw holes offset by 30 degrees in ostectomized equine MC3 bones in vitro when tested in torsion.  相似文献   

11.
OBJECTIVE: To compare monotonic mechanical properties of gap-ostectomized third metacarpal bones (MC3) stabilized with an MP35N interlocking nail system with contralateral intact bones. ANIMALS OR SAMPLE POPULATION: Twenty-four pairs of cadaveric equine MC3s. METHODS: Third metacarpal bones were divided into 4 mechanical testing groups (6 pairs per group): compression, palmarodorsal (PD) and mediolateral (ML) 4-point bending, and torsion. One MC3 from each pair was randomly selected as an intact specimen, and the contralateral gap ostectomized bone was stabilized with a 4-hole, 14-mm-diameter, 250-mm-long, MP35N intramedullary nail, and four, 7-mm-diameter, 60-mm-long MP35N interlocking screws (constructs). Mechanical testing properties were compared between intact specimens and constructs with a paired t test (significance set at P <.05). RESULTS: Intact specimens were significantly stronger and stiffer than constructs in all testing modes except PD bending. Constructs achieved mean yield strengths that were 57% (compression), 81% (PD bending), 68% (ML bending), and 78% (torque) of intact specimens. Constructs achieved mean stiffnesses that were 53% (compression), 58% (PD bending), 41% (ML bending), and 47% (torque) of intact specimens. CONCLUSION: Monotonic yield mechanical properties of MP35N intramedullary interlocking nail-stabilized, gap-ostectomized MC3 were lower than those of paired intact bones but exceeded reported in vivo loads for dorsopalmar bending and compression and estimated in vivo torsional loads. CLINICAL RELEVANCE: Considering the benefits associated with intramedullary interlocking nail fixation of fractures, this system should be considered for use for repair of MC3 fractures with applicable fracture configurations.  相似文献   

12.
The stiffness, load to failure, and bending moments of adult intact equine humeri and humeri repaired with 3 fixation techniques were determined in vitro. Bones were tested in axial compression (30 pairs), mediolateral 3-point bending (15 pairs), and caudocranial 3-point bending (15 pairs). An oblique osteotomy of 1 humerus of each pair was performed to simulate the long spiral oblique fractures that occur clinically in horses. Bones were repaired in 3 ways: group 1--nylon band cerclage fixation (20 bones); group 2--multiple intramedullary pinning (20 bones); and group 3--nylon band cerclage fixation and multiple intramedullary pinning (20 bones). Intact bones were significantly (P less than 0.05) stronger than repaired bones in each testing mode. Bones repaired with bands only were significantly less stiff in bending than were bones repaired with pins only or with pins and bands. In compression, only specimens repaired with pins and bands were significantly stiffer than were bones repaired with bands only. Bones repaired with bands only required significantly less load to failure in compression and in caudocranial bending than did bones repaired with pins only or with pins and bands. Bones repaired with pins only deformed through the full displacement of the actuator (5 cm), and pins deformed plastically. Bones repaired with pins and bands were stiffer and had higher bending moments than did bones repaired with pins only, but the differences were not significant.  相似文献   

13.
OBJECTIVE: To determine cyclic biomechanical properties of gap osteotomized adult equine tibiae stabilized with an equine interlocking nail (EIN). STUDY DESIGN: In vitro experimental biomechanical investigation. SAMPLE POPULATION: Thirteen adult equine cadaveric tibiae. METHODS: Adult equine tibiae with transverse, midshaft, 1-cm gap osteotomies, stabilized with an equine interlocking nail, underwent cyclic biomechanical testing in vitro under axial compression, 4-point bending, and torsion. Different specimens were subjected to different load levels that represented estimated in vivo loads at 2 Hz for 740,000 cycles. Fatigue life and gap strain were calculated. RESULTS: Compression and bending, but not torsional, fatigue life were longer than time necessary for bone healing. Compressive, but not bending or torsional, gap strains were small enough to be compatible with fracture healing by primary bone formation. Gap strains for compressive, bending, and torsional loads were compatible with indirect, or secondary, bone formation. CONCLUSIONS: Further modification should be made to the equine interlocking nail to increase bending stiffness and torsional fatigue life. CLINICAL RELEVANCE: The stainless steel equine intramedullary interlocking nail is unlikely to provide appropriate long-term stability for fracture healing in adult equine tibiae without modifications in the nail design and material.  相似文献   

14.
This study compared in vitro monotonic and cyclic mechanical properties of equine proximal interphalangeal joint arthrodeses stabilized using an open or closed technique combined with axial 4.5 mm narrow limited-contact dynamic compression plate (LC-DCP) or 4.5 mm narrow locking compression plate (LCP). Ten forelimb pairs were randomly assigned to LCP or LC-DCP groups. One limb in each pair was assigned to either open or closed technique. Limbs were tested for cyclic fatigue at 20 000 cycles and then single-cycle to failure under 3-point dorsopalmar bending. There was no significant difference in stiffness of constructs during cyclic fatigue testing or on force or stiffness at failure in single cycle to failure testing between open and closed techniques or between plate types. Both implants, surgical technique, or combinations thereof are suitable for clinical use. More work is necessary to define the interaction between implant type and surgical technique.  相似文献   

15.
Contact area and pressure between 6-hole broad dynamic compression plates and 20 pairs of equine third metatarsal bones were measured using nonluted and luted plating techniques. Pressure-sensitive film (pressure ranges 10 to 50 MPa and 50 to 130 MPa) was used as the static pressure transducer. Nonluted and one of two luting techniques were tested on each pair of bones; each luting technique was tested on 20 bones. Quantitative determinations of contact area and pressure were made using computerized image processing techniques. Mean (±SD) total contact area for nonluted plates was 18.49%± 3.5% of the potential plate-bone contact area. Luting increased ( P <.05) total contact area to 25.56%± 4.0% and 31.29%± 6.6% for the respective luting techniques. The effects of luting on contact area were dependent on the contact pressure. At contact pressure ranges 10 to 20 and 21 to 35 MPa, luting increased contact area. In contact pressure ranges 36 to 45 and 50 to 65 MPa, plate-bone contact was inherently greatest and plate luting had no significant effect on contact area. In contact pressure ranges 66 to 99 and 100 to 126 MPa, luting decreased contact area. Contact area was increased at lower contact pressures at the expense of higher pressure contact. Contact in the middle third of the plate was 20% to 40% of the contact at either end of the plate. Plate luting increased contact area best where plate-bone contour was most similar.  相似文献   

16.
OBJECTIVE: To evaluate a dorsoproximal extra-articular approach for insertion of 8.25-mm, solid-titanium, intramedullary (IM) interlocking nails into ostectomized foal third metacarpal (MC3) and third metatarsal (MT3) bones; to compare the monotonic mechanical properties of IM nail constructs with paired intact bones; and to determine the effects of age, body weight, fore- or hindlimb, and left or right limb on the mechanical testing variables. ANIMAL OR SAMPLE POPULATION: Twenty bone pairs (10 MC3, 10 MT3) collected from 10 foals of various weights and ages. METHODS: One bone from each pair was randomly selected to be ostectomized and stabilized using an 8.25-mm, solid-titanium IM nail, and four 3.7-mm titanium interlocking screws (construct). Constructs and contralateral intact bone specimens were tested in axial compression and palmaro-/plantarodorsal (PD) 4-point bending. Monotonic mechanical properties were compared between intact specimens and constructs with an ANOVA; significance was set at P <.05. RESULTS: Nail insertion caused bone failure in 6 MC3 and 2 MT3. In general, mean mechanical testing values indicated that intact specimens were significantly stronger and stiffer than constructs for all age and weight ranges when tested in compression and PD 4-point bending (P <.05). Bone strength and stiffness of intact specimens tested in compression and bending tended to increase linearly with age and weight. CONCLUSION: IM interlocking nail fixation of gap-ostectomized MC3 and MT3 with 8.25-mm IM nails and 3.7-mm interlocking screws did not achieve sufficient strength or stiffness to be recommended as the sole means of repair for comminuted MC3 and MT3 fractures in young foals. CLINICAL RELEVANCE: IM interlocking nail fixation of foal cannon bone fractures may be useful to decrease soft-tissue disruption at the fracture site; however, there is a risk of bone failure associated with extra-articular insertion. This method should be combined with other forms of external coaptation for added stability in axial compression and PD bending.  相似文献   

17.
OBJECTIVE: To compare the structural properties and the interfragmentary motion in ostectomized canine femurs stabilized with either an 8-mm interlocking nail system (IN) or a 10-hole dynamic compression broad plate (DCP). ANIMAL OR SAMPLE POPULATION: Ten pairs of adult canine femurs with a 25-mm mid-diaphyseal gap. METHODS: Bone specimens were divided into 2 groups (10 femurs each). Left femurs were stabilized with a DCP and 8 bicortical screws; right femurs were stabilized with an IN and 3 screws. Mechanical tests were performed in eccentric axial loading and in craniocaudal bending. The testing was first conducted nondestructively and then until breakage. Structural properties, ie, stiffness, yield limits, and failure limits, were determined. Interfragmentary motion was measured during nondestructive tests with the use of an optoelectronic device. Axial, transverse, and rotational motions were calculated. Mean values of stiffness, yield and failure limits, and axial and shear motions for each fixation method were compared using a paired t test within each group (P <.05). RESULTS: Mean (+/-SD) values of stiffness and failure limit were significantly higher for IN constructs than for DCP constructs in compression, while there was little difference in the results between each tested group in bending. Mean yield load values were significantly higher for IN than for DCP specimens in compression as well as in bending. The axial-motion analysis revealed significant differences between IN and DCP groups during bending tests only. The highest score of transverse motion at the gap was recorded during bending tests, and was higher for DCP than for IN specimens. There were insignificant differences between the two groups with regard to rotation around the diaphyseal axis. CONCLUSIONS AND CLINICAL RELEVANCE: Structural properties and interfragmentary shear motion analysis demonstrated a much higher rigidity in the IN-bone than in the DCP-bone constructs.  相似文献   

18.
The breaking strength (stress at failure) of equine third metacarpal bones, with and without clustered drill holes, was determined in vitro. Paired ossa metacarpalia II-IV of 39 horses (n = 39) between 2 and 7 years old were tested in palmarodorsal 3-point bending. Four treatments were compared. Clustered 2.7- or 3.5-mm drill holes, in a 4- or 7-hole pattern, were made in the dorsal cortex of the distal diaphysis of the left third metacarpal bone. Undrilled right third metacarpi were used as controls. Bones with clustered drill holes failed by an oblique fracture through 1 or more drill holes, whereas undrilled bones failed with a middiaphyseal transverse fracture. Clustered drill holes acted as a stress concentrator and significantly (P less than 0.05) decreased the stress required for failure. However, differences in breaking strength between treatment groups were not significant (P greater than 0.05).  相似文献   

19.
OBJECTIVE: To compare the accuracy of reduction and biomechanical characteristics of acetabular osteotomies repaired with luted and nonluted reconstruction plates. STUDY DESIGN: In vitro study. ANIMALS: Pelves removed from 12 adult greyhounds. METHODS: Acetabular osteotomies were created and repaired with a 6-hole, 2.7-mm reconstruction plates in 24 cadaver hemipelves. Ten hemipelves each were assigned to group I and group II. An impression cast of each acetabulum in group I was made before luting (preluting cast). Group I plates were then elevated, luted, and replaced. A second cast of each acetabulum in group I was then made (postluting cast). Step, gap, and total areas of articular osteotomy incongruence were determined from the casts. Group I (luted plate repairs) and group II (nonluted plate repairs) hemipelves were loaded ventral-to-dorsal using a materials-testing machine. Stiffness, yield load, and maximal load sustained were determined. RESULTS: Mean gap and total area of articular osteotomy incongruence for group I preluted plate repairs (7.1 mm(2) and 8.6 mm(2), respectively) were significantly greater than for group I postluted plate repairs (4.1 mm(2) and 5.1 mm(2), respectively). Mean stiffness and maximal load for group I (681 N/mm and 2,555 N, respectively) were significantly greater than for group II (360 N/mm and 1,730 N, respectively). Mean step area and mean load at yield values were not significantly different between groups. CONCLUSIONS: Luted plate repairs of osteotomized acetabulae result in improved reduction and are stiffer and stronger than nonluted plate repairs. CLINICAL SIGNIFICANCE: Plate luting may improve the accuracy of reduction of acetabular fractures where anatomic reduction is required. Plate luting may also increase the stiffness and strength of fracture repairs and arthrodeses.  相似文献   

20.
Objective— To compare stiffness and strength of a dynamic condylar screw plate combined with dorsal broad dynamic compression plate (DCS–bDCP) fixation with double broad dynamic compression plate (dbDCP) fixation used to repair oblique distal fractures of adult equine radii. Study Design— Experimental. Sample Population— Adult equine radii (n=10 pair). Methods— An unconstrained three‐dimensional loading–measurement system was used to determine stiffness of a 50 mm long intact, and then DCS–bDCP or dbDCP‐plated osteotomized/ostectomized segment of radii when subjected to a nondestructive sequence of compression, torsion, and lateral‐to‐medial (LM), medial‐to‐lateral (ML), cranial‐to‐caudal (CrCa), and caudal‐to‐cranial (CaCr) bending. Uniform load over the entire length of construct identified its weakest characteristics during torsion and LM and CrCa bending to failure. Results— No difference was observed between osteotomized/ostectomized DCS–bDCP and dbDCP construct stiffness for all 6 loading modes, and strength for all 3 failure loads. Ostectomized DCS–bDCP and dbDCP construct stiffness was significantly lower than osteotomized radii, the latter approaching intact for axial, LM, and CrCa bending. Most frequent failure was bone fracture through exit site of a screw located adjacent to osteotomy/ostectomy. Conclusions— DCS–DCP and dbDCP constructs had comparable strength and stiffness when repairing osteotomies/ostectomies in equine adult radius bone. Fracture reduction increased stiffness that approached intact bone for loads that placed the unplated side in compression. Clinical Relevance— DCS–bDCP and dbDCP constructs are comparable in stiffness and strength when applied to oblique distal diaphyseal osteotomies/ostectomies in equine radius bone. However, the DCS's localized effect on distal epiphyseal structure because of additional bone removal remains to be investigated under in vivo articular loading conditions.  相似文献   