首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A selective and fast method for the quantitative determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wine was developed. Microextraction in packed syringe (MEPS) was optimized for the extraction and preconcentration of the analytes using extremely small volume samples (0.1-1 mL). For GC-EI-MS, the limit of detection (LOD) for red and white wine was in the range 0.17-0.49 microg L(-1) for TCA and TBA. In addition to GC-EI-MS both GC-NCI-MS and GC-HRMS were used to further improve both selectivity and sensitivity. The lowest LODs were achieved using GC-HRMS in the EI mode. In red and white wine samples the LODs were between 0.22-0.75 ng L(-1) for TCA and TBA. The reproducibility and linearity for the GC-HRMS method was good, with RSD-values of 4-10% for spiked red wine samples at 1 ng L(-1) and linearity with R (2) > 0.962 over a concentration range of 1 to 100 ng L(-1).  相似文献   

2.
Regulations introduced by the Food Standards Australia New Zealand in December 2002 require all wine and wine product labels in Australia to identify the presence of a processing aid, additive or other ingredient, which is known to be a potential allergen. The objective of this study was to establish sensitive assays to detect and measure allergenic proteins from commonly used processing aids in final bottled wine. Sensitive and specific enzyme-linked immunosorbent assays (ELISA) were developed and established for the proteins casein, ovalbumin, and peanut. Lower limits of detection of these proteins were 8, 1, and 8 ng/mL, respectively. A panel of 153 commercially available bottled Australian wines were tested by these ELISA, and except for two red wines known to contain added whole eggs, residuals of these food allergens were not detected in any wine. These findings are consistent with a lack of residual potentially allergenic egg-, milk-, or nut-derived processing aids in final bottled wine produced in Australia according to good manufacturing practice at a concentration that could cause an adverse reaction in egg, milk, or peanut/tree-nut allergic adult consumers.  相似文献   

3.
A competitive enzyme-linked immunosorbent assay (ELISA) for pentachloronitrobenzene (PCNB), a fungicide and chemical intermediate, was developed using a polyclonal antiserum produced against a hapten-protein conjugate of pentachlorophenoxypropionic acid-bovine serum albumin (BSA). An indirect competitive ELISA of PCNB showed an IC50 of 37 ng/mL and a limit of detection (LOD) of 7 ng/mL. The ELISA can tolerate up to 10% (v/v) methanol, 5% (v/v) acetonitrile, or 5% (v/v) acetone without significant fluctuation of Amax and IC50. The assay sensitivity showed little change in a range of pH from 6 to 8 and concentrations of 0.05-0.2 M NaCl in the assay buffer. Very low cross-reactivities were observed for some structurally related compounds except for hexachlorobenzene (12%). The average recoveries of PCNB from fortified well water, river water, and soil samples were in ranges of 88-94, 80-91, and 70-81%, respectively. The correlations between the gas chromatographic and ELISA results were excellent (r 2 >or= 0.97, slopes from 0.86 to 1.10) for those fortified samples. The ELISA is a good alternative tool for monitoring PCNB residues in environmental samples.  相似文献   

4.
Enzyme-linked immunosorbent assay for T-2 toxin metabolites in urine   总被引:3,自引:0,他引:3  
A direct competitive enzyme-linked immunosorbent assay (ELISA) for determination of total T-2 toxin metabolites in urine was developed. The assay involves coating anti-3-acetyl-neosolaniol-hemisuccinate-bovine serum albumin conjugate (anti-3-Ac-NEOS-HS-BSA) antibody to the ELISA plate and using 3-Ac-NEOS-HS-peroxidase as the enzyme marker. Competitive ELISA revealed that the antibody had good cross-reactivity with acetyldiacetoxyscirpenol (Ac-DAS), T-2 tetraol tetraacetate, 3'-OH-Ac-T-2, 3-Ac-NEOS, and 3,4,15-triacetyl-12,13-epoxytrichothec-9-en-8-one (Ac-T-2-8-one), but less cross-reactivity with Ac-T-2 toxin and T-2 toxin. All metabolites of T-2 toxin in urine were converted to T-2 tetraol tetraacetate (T-2-4ol-4Ac) by acetylation of the sample extract before ELISA. To test the ELISA accuracy, a radioimmunoassay (RIA) was performed simultaneously. The linear portion of the standard curve of this direct ELISA for T-2-4ol-4Ac was 0.2-2.0 ng/mL, which was 10 times more sensitive than RIA. The minimum detection level for T-2-4ol-4Ac was 0.02 ng/mL (0.4 pg/assay) in the absence of urine sample. The overall analytical recoveries for T-2 toxin, HT-2, T-2-4ol, 3'-OH-HT-2, NEOS, and a mixture of these 5 toxins added to the urine samples in the ELISA at concentrations of 0.05 and 0.2 ng/mL were 87 and 94%, respectively.  相似文献   

5.
The analysis of salbutamol in swine serum is the more practical basis for large scale surveillance programs in Taiwan. Objectives of the study were to develop a new assay and to compare with a commercially available kit in field test screens. A simple and reliable enzyme-linked immunosorbent assay (ELISA) to monitor the presence of beta-agonist, salbutamol, in 1,358 field samples of swine serum that were collected from local meat markets was described. The method proved to be suitable and sensitive for the detection of beta-agonist residues caused by growth promoting dosage. The limit of detection of the developed ELISA directly performed on diluted serum was 0.25 ng/mL. The application and the results of two ELISA kits (homemade and commercially available) for the screening of salbutamol were presented. For further confirmation, all samples that showed to be ELISA positive for salbutamol residues were analyzed by GC-MS. Adopting 1 ng/mL salbutamol as a cutoff value, the commercial beta-agonist ELISA had a sensitivity of 89.2% and a specificity of 86.7% versus GC-MS at a cutoff of 1 ng/mL. The homemade salbutamol ELISA had a sensitivity of 81.1% and a specificity of 98.6% and gave a low proportion of false-positive rate results. The reliability of the developed kit in terms of the percentage of false-positive rate results is evaluated. In conclusion, a sensitive, specific salbutamol ELISA has been developed that could serve as a rapid screening assay, and the detection of positive samples at the place of sampling can result in more effective control of the illegal use of beta-agonists.  相似文献   

6.
The scope of this study was to evaluate the exposure of the Italian population to ochratoxin A (OTA) attributable to wine consumption. With this aim 1166 wine samples (773 red wines, 290 white, 75 rose, and 28 dessert wines), collected in 19 different Italian regions and mostly produced between 1988 and 2004, were analyzed for OTA content. The obtained results are reported by year of harvest, geographical area of production, and type of wine. Red wine showed the highest maximum level of contamination (7.50 ng/mL), even though rose wines were characterized by a higher mean value (0.01 ng/mL). A gradually increasing mean concentration was also observed from the north (0.05 ng/mL) to south of Italy (0.54 ng/mL). Exposure calculations, performed using two different consumption databases, indicate a daily intake for consumer only of 0.59 up to 1.24 ng/(kg of b.w.)/day and of 0.33 up to 0.90 ng/(kg of b.w.)/day for the total population. Even in the worst case, corresponding to the calculation of the intake for consumers only in southern Italy and Islands and considering the mean consumption data increased by 1 standard deviation, a quite low exposure (1.68 ng/(kg of b.w.)/day, accounting for 9.8% of TDI) was obtained. Considering the overall OTA dietary exposure, obtained exposure rates indicate that wine did not pose a risk to the Italian population health.  相似文献   

7.
The present work describes the design and synthesis of the structurally unique hapten, "bifunctional hapten", to produce a group-specific polyclonal antiserum to triclopyr and 3,5,6-trichloro-2-pyridinol. A bifunctional hapten was designed and synthesized by conjugating commercially available Nepsilon-2,4-dinitrophenyl (DNP)-L-lysine to triclopyr, and then coupling this to carrier proteins such as bovine serum albumin (BSA). The synthesized bifunctional hapten greatly raised the antiserum titer in comparison with that of the conventional hapten, triclopyr. Antiserum with a sufficiently high titer to provide the determinations of targeted compounds was obtained only 63 days after the primary immunization. The obtained antiserum showed the highest affinity to triclopyr (IC(50) = 3.5 nM) and 3,5,6-trichloro-2-pyridinol (IC(50) = 5.1 nM) in homologous ELISA. The cross-reactivities to various agrochemicals and some chlorinated phenolic compounds were determined. Significant cross-reactivity was found to the herbicide 2,4,5-T. The antiserum reacted to both triclopyr and its metabolite. Assay sensitivity was evaluated for effects of various assay conditions, including pH value and concentrations of organic solvents and detergents. Under optimized assay conditions, the quantitative working range of triclopyr ELISA was from 0.1 to 5.2 ng/mL with a limit of detection (LOD) of 0.037 ng/mL, and an IC(50) of 0.72 ng/mL. On the other hand, the quantitative working range of 3,5,6-trichloro-2-pyridinol ELISA was from 0.13 to 6.0 ng/mL with a LOD of 0.052 ng/mL, and an IC(50) of 0.95 ng/mL. Water samples fortified with triclopyr or its metabolite at 1, 5, and 10 ng/mL were directly analyzed without extraction and cleanup by the proposed ELISA. The mean recovery was 101.6%, and the mean coefficient of variation (CV) was 7.1% in the case of the triclopyr ELISA. In the case of the 3,5,6-trichloro-2-pyridinol ELISA, the mean recovery was 99.8%, and the mean CV was 9.5%. The proposed ELISA turned out to be a powerful tool for monitoring of residual triclopyr or 3,5,6-trichloro-2-pyridinol in water samples at trace level.  相似文献   

8.
Two enzyme-linked immunosorbent assays (ELISA) for the insecticide azinphos-methyl have been optimized and characterized. Both ELISAs are based on monoclonal antibodies produced from an immunogen with a hapten containing a phthalimido moiety and on protein conjugates of heterologous ligands containing a 1,2,3-benzotriazine group. Assay I was performed in the conjugate-coated ELISA format and assay II in the antibody-coated format. Several physicochemical factors (ionic strength, pH, incubation times, and Tween 20 and BSA concentrations) that influence assay performance were studied and optimized. Regarding specificity, both monoclonal immunoassays highly cross-reacted with azinphos-ethyl and phosmet. Finally, both assays were applied to the analysis of azinphos-methyl in spiked real water samples. For assay I the sensitivity, estimated as the I(50) value, was 0.40 nM, with a practical working range between 0.10 and 1.75 ng/mL and a limit of detection of 0.05 ng/mL. For assay II the sensitivity was 1.01 nM, with a practical working range between 0.32 and 2.54 ng/mL and a limit of detection of 0.08 ng/mL.  相似文献   

9.
To develop a competitive indirect enzyme-linked immunosorbent assay based on polyclonal antibodies for the detection of the sulfonylurea herbicide bensulfuron-methyl, seven structurally related haptens were synthesized. Four of them mimicking the target analyte were conjugated to keyhole limpet hemocyanin by the N-hydroxysuccinimide activated ester method to use as immunogens, and all of them were conjugated to bovine serum albumin to use as plate-coating antigens. Polyclonal antibodies raised in rabbits and the coating antigens were screened and selected for the assay in simple homologous and heterologous ELISA formats. Three sensitive heterologous ELISAs were selected and optimized, showing the average IC(50) values of bensulfuron-methyl as low as 0.17, 0.09, and 0.09 ng/mL, the detection ranges of 0.04-0.60, 0.01-0.60, and 0.04-0.25 ng/mL, and the lowest detection limits of 0.03, 0.002, and 0.03 ng/mL, respectively. The cross-reactivities of other sulfonylurea herbicides and metabolites of bensulfuron-methyl to the antibodies were less than 15% in the two assays. Recoveries from the analyte-fortified water samples in assay I were in the range of 81-125% by simple dilution. The correlation between the ELISA and HPLC was 0.999 (n = 15) with a slope of 1.37 in the analysis of groundwater samples fortified with bensulfuron-methyl. The results obtained strongly indicate that the ELISA can be a highly sensitive and convenient tool for detecting bensulfuron-methyl residues in agricultural and environmental samples.  相似文献   

10.
A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of the organophosphorus insecticide bromophos-ethyl. Four bromophos-ethyl derivatives (haptens) were synthesized and were coupled to carrier proteins through the pesticide thiophosphate group to use as an immunogen or as a coating antigen. Rabbits were immunized with either one of two haptens coupled to bovine serum albumin for production of polyclonal antibodies, and the sera were screened against one of the haptens coupled to ovalbumin. Using the serum with highest titer, an antigen-coated ELISA was developed, which showed an IC(50) of 3.9 ng/mL with a detection limit of 0.3 ng/mL (20% inhibition). An antibody-coated ELISA using an enzyme tracer was also developed, which showed an IC(50) of 6.5 ng/mL with a detection limit of 1.0 ng/mL (20% inhibition). The antibodies showed negligible cross-reactivity with other organophosphorus pesticides except with the insecticides bromophos-methyl and chlorpyrifos in the antibody-coated assay only. Recoveries of bromophos-ethyl from fortified crop and water samples ranged from 82 to 128% and from 95 to 127%, respectively.  相似文献   

11.
A monoclonal antibody (mAb) specific to domoic acid was produced from a stable hybridoma cell line, 9F1F11, generated by the fusion of P3/NS1/1-AG4-1 myeloma cells with spleen cells isolated from a Balb/c mouse immunized with domoic acid--keyhole limpet hemocyanin. The 9F1F11 mAb belongs to the immunoglobulin G1 (kappa-chain) isotype. A competitive direct enzyme-linked immunosorbent assay (cdELISA) and a competitive indirect ELISA were established for antibody characterization. In the cdELISA, the concentration causing 50% inhibition (IC50) of binding of domoic acid-horseradish peroxidase to the antibody by domoic acid was found to be 0.58 ng/mL. A sensitive and rapid mAb-based colloidal gold immunostrip was also developed. The immunostrip assay, which has a detection limit of 5 ng/mL for domoic acid, can be completed in 10 min. Analysis of domoic acid in blue mussel samples revealed that data obtained from immunostrip were in a good agreement with those obtained from cdELISA. The mAb-based cdELISA and immunostrip assay established in this study were sensitive and accurate for rapid screening of domoic acid in shellfish samples.  相似文献   

12.
A monoclonal antibody-based ractopamine immunoassay has been applied to incurred samples from sheep and cattle. Results obtained by immunoassay were compared with those from high-performance liquid chromatography (HPLC). Three sets of sample extracts containing primarily unmetabolized ractopamine were analyzed. Correlation of HPLC with enzyme-linked immunosorbent assay (ELISA) for beef liver samples gave an r(2) = 0.98 despite rather low ractopamine concentrations (range 1.1-13.4 ng/mL, n = 6). Ractopamine concentrations in cow urine samples treated by solid phase extraction, to remove ractopamine metabolites, also showed a high correlation between the HPLC and the ELISA results (r(2) = 0.95, range 1.0-275 ng/mL, n = 61). In contrast, HPLC and ELISA analyses of ractopamine in sheep urine were not well-correlated (r(2) = 0.58, range 0.85-51 ng/mL, n = 34). When ractopamine conjugates in urine samples were hydrolyzed with hydrolytic enzymes, ELISA and HPLC methods were highly correlated [r(2) = 0.94 for sheep (range 123-10 554 ppb, n = 60) and an r(2) = 0.98 for cattle (range 14-8159 ppb, n = 62)]. Tissues contained only minute amounts of ractopamine, and after 7-day withdrawal periods, less than 1 ppb of free ractopamine was detected. Ractopamine was rapidly metabolized in both cattle and sheep. The difference in ractopamine concentration of urine samples before and after hydrolysis indicated that only 1-5% of ractopamine was excreted unmetabolized. Results from this study indicate that the monoclonal antibody-based ELISA could be useful for a sensitive, quantitative, or qualitative ractopamine screening assay.  相似文献   

13.
A sandwich enzyme-linked immunosorbent assay (ELISA) has been developed for detection of α-amylase in preharvest sprouted wheat and adapted to rapid field-use formats requiring 15–20 min to perform. Polyclonal and monoclonal antibodies were prepared to detect a mixture of high and low pI isozymes of α-amylase and high pI isozymes only. All antibodies detected α-amylase on immunoblots of either a crude wheat extract or of purified enzyme, but only the polyclonal antibodies functioned in a sandwich ELISA. Depending on the antibody combination, the tube ELISA detected either the high and low pI isozymes of α-amylase or the high pI isozymes only with a detection limit of ≈0.5–1.0 ng/mL of amylase. Wheats with falling numbers (FN) of <350 sec could be discriminated from sound wheats, with decreasing FN producing increasing assay color. Using 130 wheat grain samples, ELISA absorbances for detection of both high and low pI isozymes and of high pI isozymes only were highly positively correlated with amylase enzyme activity and negatively correlated with FN. The correlations were similar for detection of both isozyme families and for detection of high pI isozymes only. Analyses of three sets of wheat samples from different environments demonstrated that the relationship between ELISA absorbance and FN had little dependence on wheat cultivar. The precision of sample analysis using the field ELISA was similar to the precision of FN test apparatus.  相似文献   

14.
A competitive direct enzyme-linked immunosorbent assay (ELISA) and high-pressure liquid chromatographic (HPLC) methods were compared in terms of accuracy and precision for the detection and quantification of glyphosate-spiked Nanopure, tap, and river waters. The ELISA had a detection limit of 0.6 ng mL(-)(1) and a linear working range of 1-25 ng mL(-)(1), whereas the HPLC method had a detection limit of 50 ng mL(-)(1) and a linear working range of 100-10000 ng mL(-)(l). No statistically significant differences (95% confidence interval) were found between the ELISA and HPLC analysis of the three water matrixes. The coefficients of variation obtained with the ELISA in tap water were between 10 and 19%, whereas the coefficients of variation for the HPLC analysis were between 7 and 15%. The use of ELISA for the analysis of glyphosate in water is a cost-effective and reliable method capable of meeting water quality guidelines established for Europe and North America.  相似文献   

15.
For development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the organophosphorus insecticide fenitrothion, the specificity of the antiserum R-3 generated with the bifunctional hapten, LysMNPA (2-[[[(3-methyl-4-nitrophenyl)oxy]methylcarbonyl]amino]-6-(2,4-dinitrophenyl)aminohexanoic acid) and the application to the residual analysis of some water samples were evaluated. At optimized ELISA conditions, the quantitative working range was from 1 to 39 ng/mL with a limit of detection of 0.3 ng/mL and an IC(50) value of 6 ng/mL. Cross-reactivity to structurally similar organophosphorus compounds and related chemicals was determined. The antiserum R-3 showed significant cross-reactivity with fenitrooxon and 3-methyl-4-nitrophenol, which have a 3-methyl-4-nitrophenoxy group as common structures, but showed relatively low cross-reactivity with other compounds. Each water sample (river water, tap water, purified water, and bottled water) had a matrix effect and was investigated by adding Tween 20 in the assay buffer. These four kinds of water samples were fortified with fenitrothion at several concentration levels and were directly analyzed with only dilution with an equal volume of antiserum solution. The mean recovery was 105.9%, and the mean coefficient of variation was 10.9%. The results suggested that the developed ELISA would be very suitable for a preliminary screening for fenitrothion in water samples at such low levels.  相似文献   

16.
A highly selective and sensitive indirect competitive enzyme-linked immunosorbent assay (ELISA) for Sudan I was developed. Two hapten derivatives with different lengths of carboxylic spacer at the azo-bound para-position were synthesized and coupled to carrier proteins. The hapten-bovine serum albumin (BSA) conjugates were used as immunogens, while the hapten-ovalbumin (OA) conjugates were applied as coating antigens. The antisera which were obtained from four immunized rabbits were characterized in terms of sensitivity and specificity. At optimal experimental conditions it was found that IC50 and LOD values of seven pairs based on four antisera and two coating antigens were in the range of 0.3-2 ng/mL and 0.02-0.1 ng/mL, respectively. The most sensitive ELISA could be established with Sudan I-propionic acid-OA coating antigen and the antiserum which was obtained with the corresponding immunogen. The cross-reactivity values of the four antisera with Sudan II, III, and IV was estimated with 0.1-14.3%. No cross-reactivity was found with six edible colorants Sunset yellow, Amarant, Kermes, Indigotin, Bright blue and Lemon yellow, indicating high specificity for Sudan I. Six food samples were fortified with Sudan I and extracted by simple sample preparation. The methanolic extracts after dilution with methanol:water (5:95, v/v) were analyzed by the developed ELISA. Assay precision and accuracy was estimated by determination of three replicates. Acceptable recovery rates of 92.5-114% and intra-assay coefficients of variation of 5.9-24.8% were obtained. The data were validated by conventional HPLC method. As revealed, both methods were highly correlated (r = 0.9851, n = 7), demonstrating the applicability of the developed ELISA for Sudan I analysis in food samples.  相似文献   

17.
Competitive direct enzyme-linked immunosorbent assay (ELISA) and the immunochromatographic assay were developed using a monoclonal antibody to detect gentamicin in the animal plasma and milk. No cross-reactivity of the antibody was observed with other aminoglycosides based on competitive direct ELISA, indicating that the antibody is highly specific for gentamicin. On the basis of the standard curves, the detection limits were determined to be 0.9 ng/mL in phosphate-buffered saline (PBS), 1.0 ng/mL in plasma, and 0.5 ng/mL in milk, respectively. Recoveries of gentamicin from spiked plasma and milk at levels of 25-100 ng/mL ranged from 85 to 112%. The concentration of intramuscularly injected gentamicin was successfully monitored in the rabbit plasma through competitive direct ELISA. The detection limits were estimated to be about 6 ng/mL of gentamicin in PBS, plasma, and milk using the colloidal gold-based immunochromatographic assay, which is suitable for the simple screening of gentamicin residues in the veterinary field. Observed positives can be confirmed using a more sensitive laboratory method such as competitive direct ELISA. Therefore, the assays developed in this study could complement each other as well as veterinary field and laboratory findings.  相似文献   

18.
A competitive indirect enzyme-linked immunosorbent assay (ciELISA) for the organophosphorus insecticide acephate, O,S-dimethyl acetylphosphoramidothioate, was developed using a polyclonal antibody. Five different haptens mimicking the analyte were synthesized and conjugated with the carrier proteins bovine serum albumin (BSA) and keyhole limpet hemocyanin (KLH) by the N-hydroxysuccinimide active ester and diazotization methods. Polyclonal antibodies raised against hapten-KLH conjugates in rabbits and hapten-BSA conjugates as coating antigens were screened and selected for the assay in the homologous and heterologous ELISA systems. The effects of various assay conditions such as detergent, organic solvents, pH, and preincubation of the mixture of the polyclonal antibody and the analyte on the sensitivity were evaluated. The IC(50) value for acephate was 25 ng/mL in an optimized heterologous system using hapten-4-BSA as a coating antigen and a polyclonal antibody no. 8377 against hapten-1-KLH, showing the detection range of 5-140 ng/mL and the lowest detection limit of 2 ng/mL. The cross-reactivities of the structurally related organophosphorus insecticides, including the major metabolite of the analyte, methamidophos, were less than 1%. Recoveries from the analyte-fortified tap water, mulberry leaves, and lettuce samples in the assay were in the range of 72-121% by simple extraction, concentration, and dilution. These results indicate that the ELISA could be a convenient and supplemental analytical tool for monitoring acephate residues in environmental and agricultural samples.  相似文献   

19.
An enzyme-linked immunosorbent assay (ELISA) for fipronil was developed by using polyclonal antibodies (pABs) or monoclonal antibodies (mABs), and its suitability of the determination of this analyte in spiked water samples was studied. The pABs-based assay showed I50 = 17.95 ppb, I90 = 203.40 ppb, and I10 = 0.066 ppb, whereas the mABs-based assay showed I50 = 5.99 ppb, I90 = 485.40 ppb, and I10 = 0.074 ppb. The recoveries of fipronil from tap water samples by pABs-based ELISA were 93.00-124.00% in the range of 0-500 ng/mL, and those obtained from the samples by mABs-based ELISA were 94.70-108.00%. Different types of water from pool, river, and sea were spiked at different levels (ranging form 0.1 to 10 microg/L) and were assayed by the indirect ELISA with mABs. The recoveries of fipronil by this ELISA were in the range of 80-120%. The results demonstrate that this assay is suitable for the quantitative detection of fipronil at trace levels in water samples.  相似文献   

20.
To develop an enzyme-linked immunosorbent assay for the fungicide fenarimol, two synthesized haptens, haptens-1 and -2, and the purchased 4,4'-DDA were conjugated to carrier proteins (BSA, KLH, and OVA). Polyclonal antibodies raised against hapten-1,2-KLH conjugates in rabbits and the coating antigens of hapten-1,2-BSA conjugates, hapten-2-OVA conjugate, and 4,4'-DDA-BSA conjugate were screened and selected for the homologous and/or heterologous ELISA formats. Two competitive indirect ELISAs were selected: assays I and II. The optimized ciELISAs of assays I and II showed average IC(50) values of fenarimol of 5.4 and 9.4 ng/mL, detection ranges of 1.1-25.9 and 1.1-82.7 ng/mL, and lowest detection limits of 0.3 and 0.3 ng/mL, respectively. The cross-reactivities with several structurally related compounds indicated the importance of the steric fitness in the antigen-antibody interaction. Recoveries of fenarimol from apple and pear samples spiked with the analyte by assay I were in the range of 93-113% by simple extraction, concentration, and dilution. This assay could be a convenient and supplemental analytical tool for monitoring fenarimol residues in environmental and agricultural samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号