首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
A simple and rapid multiplexed sandwich chemiluminescent enzyme immunoassay has been developed for the simultaneous detection of Escherichia coli O157:H7, Yersinia enterocolitica, Salmonella typhimurium, and Listeria monocytogenes. To achieve the multiplexed detection of the four pathogens, a new polystyrene 96 well microtiter plate format has been designed, in which each main well contains four subwells in the bottom. The monoclonal antibodies specific for each bacteria were separately immobilized in each subwell. When the samples were added to the main wells, the bacteria able to specifically bind to the corresponding monoclonal antibody were captured in one of the four subwells. Subsequently, a mixture of peroxidase-labeled polyclonal antibodies against the four bacteria was added and the peroxidase activity of the bound polyclonal labeled antibodies in each well was measured by an enhanced luminol-based chemiluminescent cocktail using a low-light charge-coupled imaging device. The assay was simple and fast, and the limit of quantification was in the order of 104-105 CFU/mL for all bacterial species. The accuracy of the method, evaluated by comparison of the results with a conventional culturing methodology, was satisfactory, with recovery values ranging from 90 to 120%. This method can be used as a screening test to evaluate the presence of these pathogen bacteria in different foodstuffs.  相似文献   

2.
A rapid, selective, sensitive, accurate, and inexpensive immunosensor for gibberellin acid detection was designed by coupling immunoassay with the square wave anodic stripping voltammetry (SWASV) technique involving copper ion labeled antigen in the competitive immunoreaction. The response signal expressed as the percentage of current reduction CR % (y) is linearly related to the concentration of GA (x) in the 1 microg/mL to approximately 150 microg/mL range with a regression equation of the form y = 0.44x + 15.59 and a correlation coefficient of 0.99. The results of the immunosensor assay were compared with those obtained by HPLC and ELISA, which show a satisfactory agreement. The immunosensor was used to determine the GA content in the hybrid rice grain samples taken in the growing period.  相似文献   

3.
This study investigated the production of polyclonal (pAB) antibodies and the first time production of monoclonal (mAB) antibodies against the mycotoxin alternariol, and their implementation in enzyme immunoassay (EIA) for the rapid determination of alternariol in foods. Both EIAs were highly sensitive, with detection limits (IC??) of 35 ± 6.9 pg/mL (mAb EIA) and 59 ± 16 pg/mL (pAb EIA). Food products (n = 109; apple and tomato products, white wine) from German retail shops were analyzed. At a detection limit of 1-2 μg/kg, alternariol at 1-13 μg/kg was found with high frequency in apple (67%) and tomato (93%) products. Tomatoes with visible signs of Alternaria infection, stored at room temperature for up to 4 weeks, contained alternariol at levels up to 50 mg/kg, as determined by EIA and HPLC-FLD. It is concluded that the alternariol immunoassays present a versatile screening tool which could facilitate food control for Alternaria toxins.  相似文献   

4.
A monoclonal anti-anti-idiotype antibody (mAb3) against fumonisin B(1) (FmB1) was produced from the hybridoma cell line 7C7F4, which was generated by the fusion of P3/NS-1/1-AG4-1 myeloma cells with spleen cells isolated from a Balb/c mouse that had been immunized with the Fab fragments of affinity-purified anti-idiotype antibodies. The mAb3 belongs to the immunoglobulin M, kappa light chain. A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) and an indirect competitive ELISA (idc-ELISA) were established for antibody characterization and toxin analysis. In an idc-ELISA using FmB1-ovalbumin (OVA) as the coating antigen, the concentrations causing 50% inhibition of binding (IC(50)) of mAb3 to the solid-phase FmB1-OVA by free FmB1, FmB2, and FmB3 were found to be 75, 95, and 450 ng/mL, respectively. In the dc-ELISA, the concentration causing IC(50) of FmB1-horseradish peroxidase to the solid-phase mAb3 by free FmB1 was found to be 233 ng/mL. Analysis of 12 samples naturally contaminated with fumonisins with mAb3-based idc-ELISA and polyclonal-based dc-ELISA showed a good correlation between these two methods with a correlation coefficient of 0.76 at p < 0.02. The linear regression slope was found to be y[polyclonal ELISA] = 0.87x[mAb3 ELISA] - 52 ppb.  相似文献   

5.
苯巴比妥(PB)经化学修饰在其苯环上引入活性基团氨基,合成半抗原对氨基苯巴比妥(pAPB),用重氮化法将pAPB偶联于BSA,合成人工抗原BSA-pAPB,并用红外(IR)、紫外(UV)、SDS-PAGE鉴定;用BSA-pAPB免疫Balb/C小鼠,细胞融合技术建立抗PB的单克隆抗体mAb(PB mAb)杂交瘤细胞株,体内诱生腹水法制备PB mAb,并鉴定其免疫学特性。结果表明,BSA-pAPB偶联成功,偶联率为1∶19;筛选出1B9、3C4、3F6、4E6共4株杂交瘤细胞,其中最好的4E6株间接ELISA效价细胞培养上清为1∶8.1×102,腹水为1∶6.4×105,同种型为IgG1/κ,亲和常数(Ka)为2.08×1010L/mol,对PB的半数抑制浓度(IC50)为11.35μg/L,与巴比妥的交叉反应率(CR%)为12.4%,与其他化合物无CR。本试验研制出高效价、敏感、特异的PB mAb,可用于PB残留检测的免疫学实验。  相似文献   

6.
磺胺二甲氧嘧啶单克隆抗体的制备及其免疫学特性鉴定   总被引:1,自引:1,他引:0  
用重氮化法将SDM(磺胺二甲氧嘧啶)偶联于载体蛋白BSA和OVA,合成免疫原BSA-SDM和包被原OVA-SDM,并用紫外扫描(UV)、SDS-PAGE进行鉴定;用BSA-SDM免疫BALB/C小鼠,间接ELISA和阻断ELISA选择细胞融合备用鼠;应用杂交瘤技术建立分泌SDM mAb细胞株,用体内诱生腹水法制备SDM mAb;对SDM mAb的效价、亲和性、敏感性和特异性等免疫学特性进行鉴定。结果表明,BSA-SDM人工抗原制备成功,分子结合比约为1∶12.1;筛选出1B43、D9、4E1共3株敏感特异的杂交瘤细胞,间接ELISA效价细胞培养上清分别为1∶3.2×102、1∶5.12×102、1∶8.1×102,腹水分别为1∶2.56×105、1∶2.56×1051、∶5.12×105,4E1亲和常数(Ka)为1.25×1010L/mol;4E1株对SDM的IC50为16.64ng/ml,与磺胺-6-甲氧嘧啶交叉反应率为5%,与其他磺胺类药物无交叉反应性。本试验获得了抗SDM高价、敏感、特异的mAb,可用于SDM残留检测的免疫学试验。  相似文献   

7.
喹乙醇单克隆抗体的制备及其免疫学特性的鉴定   总被引:1,自引:0,他引:1  
通过质谱法鉴定合成喹乙醇-半琥珀酸酯(OLA-HS),紫外法及凝胶电泳法鉴定全抗原OLA-BSA和OLA-OVA后,使用杂交瘤技术制备喹乙醇单克隆抗体(OLA mAb),对其效价、亲和力、敏感性、特异性及亚型进行鉴定,并通过体内诱生腹水法进行大量制备。试验结果表明,本研究成功制备了OLA-HS,且半抗原与载体蛋白偶联成功;筛选出的5株杂交瘤细胞单抗同种型均为IgG1,细胞培养上清间接ELISA效价在1∶3.0×102~1∶1.28×103之间,用4E12细胞株制作的腹水效价为1∶5.12×105。OLAmAb亲和常数Ka为3.75×1010L/mol,对OLA的IC50为1.51ng/ml,且具有较好的特异性。试验获得了高效价、敏感、特异的OLA mAb,可用于动物性食品中OLA残留检测的免疫学试验。  相似文献   

8.
分别通过1,4丁二醚法和EDC法将特布他林偶联于载体蛋白BSA和OVA上,用BSA-TBL免疫BALB/c小鼠,经过3次免疫后,OVA-TBL包被后用间接ELISA和阻断ELISA选择细胞融合备用鼠,选择高效价、高敏感性和高特异性的小鼠进行抗原进行冲击免疫;无菌手术取其脾细胞与骨髓瘤细胞融合建立分泌TBL单克隆抗体的杂交瘤细胞株;采用体内诱生腹水法制备TBL mAb,并对TBL mAb的效价、敏感性和特异性等免疫学特性进行鉴定。结果显示,免疫的6只小鼠血清抗体效价均达到10-4;融合后筛选出4C08-G5和3H3-A02共2株敏感特异的杂交瘤细胞,其细胞培养上清液效价分别为1∶800和1∶1600,腹水效价分别为1∶2.56×105和1∶1.02×106;4C08-G5株分泌的抗体对TBL的IC50为5.25ng/ml,与瘦肉精、莱克多巴胺等其他β2激动剂交叉反应性小于3%。本试验获得了抗TBL mAb,为TBL残留免疫检测方法的建立奠定了坚实的基础。  相似文献   

9.
An automated fluorescent microsphere-based flow cytometric triplex immunoassay, using the Luminex 100 flow analyzer with MultiAnalyte Profiling (xMAP) technology, was developed for the simultaneous detection of proteins from three vegetable sources as potential fraudulent adulterants in milk powder. In the final triplex inhibition immunoassay, soluble wheat proteins (SWP) and proteins from soy and pea were coupled to three different microsphere sets. A mixture of these microsphere sets was transferred to a microtiter plate well together with the sample and a mixture of three affinity-purified polyclonal antibodies raised against the proteins and labeled with a fluorophore (Alexa 532). After incubation for 1.5 h at room temperature in the dark, the fluorescence intensities on the microspheres were directly measured (no wash procedure) in the Luminex during 10 s per well (100 microspheres per set). The sensitivities of the three assays for plant protein extracts were determined as 0.5-0.6 microg/mL at 50% inhibition. For the detection of the vegetable proteins in milk powder, the samples were dissolved in buffer (0.1 g in 10 mL) and further diluted (20 times) to create a 50% inhibition at approximately 0.5% of the vegetable proteins in the total protein content of milk powder. With the help of calibration standards, prepared under conditions comparable to those for sample materials, the triplex immunoassay proved to be quantitative above 0.1%, although concentrations in high-heated milk powders were underestimated. Due to the xMAP technology, in which 100 different microsphere sets can be distinguished, this triplex immunoassay can easily be extended to detect other possible adulterants.  相似文献   

10.
Diarrhetic shellfish poisoning (DSP) toxins pose a serious health risk for consumers of bivalves and other shellfish, as well as a huge economic burden for the bivalve-producing farmers. In this work, the aim was to utilize a solubilization-based protein-isolation method to produce a low-DSP toxin protein isolate from toxic blue mussels that are unsuitable for the whole shellfish market. A homogenate of whole mussel meat was solubilized at low pH (2.8) or high pH (11.1), followed by centrifugation and reprecipitation of the solubilized mussel proteins at the isoelectric pH. In a second centrifugation, precipitated proteins were collected. These processes resulted in 81 (acid solubilization) and 72% (alkaline solubilization) reduction in the initial DTX-1 toxin content of the mussel meat. No other DSP toxins were found in the protein isolates. Acid processing of mussel meat resulted in 50% reduction in the total lipid content, while alkaline treatment did not significantly affect the lipid content. The effect of citric acid and calcium chloride addition to the mussel meat-water homogenate on lipid and toxin content was also investigated. A poor correlation factor was surprisingly obtained between reductions in DTX-1 toxin and lipids in protein isolates from processed toxic mussels. Results from an analytical mass balance of the DTX-1 toxin during acid processing showed that 61% of this toxin ended up in the aqueous supernatant after the second centrifugation. The present study presents a promising alternative way of utilizing mussels for food production in periods when they are toxic.  相似文献   

11.
Hybridomas secreting a monoclonal antibody (mAb) against the herbicide chlorimuron-ethyl (CE) were produced by fusing the mouse myeloma cell line (SP2/0) with splenocytes from a mouse immunized against the conjugate of the sulfonamide moiety of CE and bovine serum albumin (BSA). The mAb, designated 1F5C5A10, had very weak affinity with metsulfuron, ethametsulfuron, pyrazosulfuron, bensulfuron, and chlorsulfuron. Two mAb-based indirect competitive enzyme-linked immunosorbent assays (icELISA) were developed. A conventional icELISA (icELISA-I) showed a concentration of half-maximum inhibition (IC(50)) of 11.6 ng/mL with a dynamic range of 1.6-84 ng/mL. A simplified icELISA (icELISA-II) had an IC(50) of 28.7 ng/mL and a dynamic range of 2.2-372 ng/mL. The two assays were tested on spiked water and soil samples. CE (1-500 ng/mL) fortified in water samples could be analyzed directly without any sample preparation by both immunoassays with an average recovery between 74 and 114%. icELISA-II, but not icELISA-I, was able to accurately analyze the herbicide residues in the crude soil extracts with recoveries between 99 and 129% without obvious matrix effects due to its lesser amount of sample used. In contrast to icELISA-I, icELISA-II is more convenient, whereas it consumes more reagents of coating antigen and goat anti-mouse IgG-peroxidase.  相似文献   

12.
A competitive enzyme-linked immunoassay (ELISA) for the quantitation of Penoxsulam [2-(2,2-difluoroethoxy)-6-(trifluoromethyl-N-(5,8-dimethoxy[1,2,4]triazolo[1,5-c]pyrimidin-2-yl))benzenesulfonamide] in ground and surface waters was developed. This immunoassay utilizes magnetic particles as the solid phase to which polyclonal rabbit anti-Penoxsulam antibodies are attached. The ELISA has an estimated detection limit of 0.17 ppb (microg/mL) of Penoxsulam in water. Specificity studies indicate that the antibody can distinguish Penoxsulam from its major metabolites and structurally similar pesticides. Interference studies indicate that the ELISA has a wide tolerance of sample pH and salinity and for compounds commonly found in surface and ground waters. The ELISA was shown to compare favorably to LC-MS/MS on ground and surface water samples (r(2) = 0.957). The various studies performed demonstrate the usefulness of the ELISA technique as a rapid and high-throughput analytical method for the cost-effective monitoring of water samples.  相似文献   

13.
This paper reports on the generation of monoclonal antibodies and the development of a new enzyme-linked immunosorbent assay (ELISA) for the detection of molinate (S-ethyl hexahydroazepine-1-carbothioate). Hybridoma cells were generated using spleen and lymph node cells from a mouse immunized with S-2-carboxyethyl hexahydroazepine-1-carbothioate conjugated to keyhole limpet hemocyanin. After screening with a competitive ELISA, two monoclonal antibodies, mAbs 16C11 and 14D7, with IC(50) values of 82 +/- 2 and 173 +/- 8 ng/mL, respectively, were selected. MAb 16C11 can detect molinate concentrations of 1 ng/mL with no cross-reactivity to any other thiocarbamate pesticides; however, it was susceptible to the presence of organic solvents and to variation in buffer ionic strength. MAb 14D7 tolerated concentrations up to 5% of propylene glycol and 12.5% of acetonitrile in the assay buffer. The sensitivity of mAb 14D7 was further improved by decreasing the amount of coating antigen in the ELISA; the final inhibition assay showed an IC(50) of 69.2 +/- 1.4 ng/mL. In summary, mAb14D7 provided a more sensitive and robust assay, as compared with previous polyclonal antibody-based assays, with the additional advantage of being based upon a consistent and unlimited source of a defined reagent.  相似文献   

14.
A monoclonal antibody-based ractopamine immunoassay has been applied to incurred samples from sheep and cattle. Results obtained by immunoassay were compared with those from high-performance liquid chromatography (HPLC). Three sets of sample extracts containing primarily unmetabolized ractopamine were analyzed. Correlation of HPLC with enzyme-linked immunosorbent assay (ELISA) for beef liver samples gave an r(2) = 0.98 despite rather low ractopamine concentrations (range 1.1-13.4 ng/mL, n = 6). Ractopamine concentrations in cow urine samples treated by solid phase extraction, to remove ractopamine metabolites, also showed a high correlation between the HPLC and the ELISA results (r(2) = 0.95, range 1.0-275 ng/mL, n = 61). In contrast, HPLC and ELISA analyses of ractopamine in sheep urine were not well-correlated (r(2) = 0.58, range 0.85-51 ng/mL, n = 34). When ractopamine conjugates in urine samples were hydrolyzed with hydrolytic enzymes, ELISA and HPLC methods were highly correlated [r(2) = 0.94 for sheep (range 123-10 554 ppb, n = 60) and an r(2) = 0.98 for cattle (range 14-8159 ppb, n = 62)]. Tissues contained only minute amounts of ractopamine, and after 7-day withdrawal periods, less than 1 ppb of free ractopamine was detected. Ractopamine was rapidly metabolized in both cattle and sheep. The difference in ractopamine concentration of urine samples before and after hydrolysis indicated that only 1-5% of ractopamine was excreted unmetabolized. Results from this study indicate that the monoclonal antibody-based ELISA could be useful for a sensitive, quantitative, or qualitative ractopamine screening assay.  相似文献   

15.
Staphylococcus aureus enterotoxin B (SEB) is a highly heat resistant enteric toxin with a potential as a biothreat agent. A sensitive method for the detection of staphylococcal enterotoxins is needed for food safety and food defense monitoring. The objectives of this research were to develop a competitive fluorescent immunoassay with detection of SEB below toxic levels of 1 ng/mL and to minimize sample preparation. Anti-SEB was immobilized onto carboxylated polystyrene microparticles, and SEB was labeled with fluorescein isothiocyanate (FITC). The concentrations of these reagents were optimized for the detection of SEB below 1 part per billion (1 ng/mL), and other assay conditions (sample volumes and incubation periods) were optimized. Drinking water and milk samples were spiked with 0.125-10 ng/mL SEB and were equilibrated overnight prior to analysis. The water and milk samples were directly analyzed, but heating the milk samples for 10 min at 90 degrees C improved the assay performance. SEB in samples bound with the anti-SEB linked to the latex followed by the competitive binding of SEB-FITC tracer. The excess, unbound tracer was separated by centrifugation, and the fluorescence density of the supernatant was measured. SEB was detected at levels as low as 0.125 ng/mL in drinking water and 0.5 ng/mL in whole milk. This fluorescent latex particle immunoassay will be utilized for the detection of SEB in various foods matrices.  相似文献   

16.
A monoclonal antibody (mAb) specific to domoic acid was produced from a stable hybridoma cell line, 9F1F11, generated by the fusion of P3/NS1/1-AG4-1 myeloma cells with spleen cells isolated from a Balb/c mouse immunized with domoic acid--keyhole limpet hemocyanin. The 9F1F11 mAb belongs to the immunoglobulin G1 (kappa-chain) isotype. A competitive direct enzyme-linked immunosorbent assay (cdELISA) and a competitive indirect ELISA were established for antibody characterization. In the cdELISA, the concentration causing 50% inhibition (IC50) of binding of domoic acid-horseradish peroxidase to the antibody by domoic acid was found to be 0.58 ng/mL. A sensitive and rapid mAb-based colloidal gold immunostrip was also developed. The immunostrip assay, which has a detection limit of 5 ng/mL for domoic acid, can be completed in 10 min. Analysis of domoic acid in blue mussel samples revealed that data obtained from immunostrip were in a good agreement with those obtained from cdELISA. The mAb-based cdELISA and immunostrip assay established in this study were sensitive and accurate for rapid screening of domoic acid in shellfish samples.  相似文献   

17.
A rapid and simple immunochemical method was developed for the assessment of the creatine kinase (MM) isoenzyme [CK(MM)], a protein marker linked with animal welfare and meat quality. The one-step time-resolved immunofluorometric assay produced quantitative results from serum or whole blood samples in 20 min. The analytical limit of detection (mean + 2s) for the immunoassay was 17 ng/mL (n = 6), and the functional limit of detection for the analysis of porcine whole blood samples was 426 ng/mL (n = 24). The working range of the method was linear up to 50 micro g/mL, and the within-assay precision varied between 2.1 and 10.9%. The analysis of porcine serum samples showed that the results from the immunoassay method and colorimetric CK enzyme activity determination were highly correlated (r(2) = 0.965, n = 17, p < 0.001). The practicability of the assay was demonstrated by the analysis of 300 porcine whole blood samples in a slaughterhouse environment.  相似文献   

18.
Bovine somatotropin (bST) and insulin-like growth factor-1 (IGF-1) are peptide hormones that are involved in the regulation of milk production in dairy cows. Because these hormones are present at extremely low concentration in fresh and processed bovine milk, a highly sensitive and specific electrochemiluminescent immunoassay (ECLIA) has been developed to better estimate the concentration of these hormones in milk. The assay employs an imager, a capture antibody bound to a carbon electrode, and a detection antibody coupled to a ruthenium label. In the presence of tripropylamine and an electric pulse, ruthenium generates light proportional to the amount of antigen bound, and the light is captured as signal by a charge-coupled device (CCD) camera. Using bovine milk as the starting matrix, 99.69% of bST and 104.79% of IGF-1 were recoverable. The limit of detection (LOD) was <5 pg/mL for bST and <1 pg/mL for IGF-1. The limit of quantification (LOQ) was <14 pg/mL for bST in milk and <2 pg/mL of IGF-1. The assay is highly specific and shows <0.2% cross-reactivity with other peptide hormones found in bovine milk such as insulin and IGF-2. These data indicate this new, ECLIA is highly sensitive and specific for estimating the concentration of bST or IGF-1 in milk.  相似文献   

19.
An ultrahigh-performance liquid chromatography (UHPLC) tandem mass spectrometric (MS/MS) method was developed for the simultaneous quantification of 2-acetyl-4-tetrahydroxybutylimidazole (THI), 2- and 4-methylimidazoles (2-MI and 4-MI), and 5-hydroxymethylfurfural (HMF) in beverage samples. A C30 reversed-phase column was used in this method, providing sufficient retention and total resolution for all targeted analytes, with an MS/MS instrument operated in selected reaction monitoring (SRM) mode for sensitive and selective detection using isotope-labeled 4-methyl-d(3)-imidazole (4-MI-d(3)) as the internal standard (IS). This method demonstrates lower limit of quantification (LLOQ) at 1 ng/mL and coefficient of determination (r(2)) >0.999 for each analyte with a calibration range established from 1 to 500 ng/mL. This method also demonstrates excellent quantification accuracy (84.6-105% at 5 ng/mL, n = 7), precision (RSD < 7% at 5 ng/mL, n = 7), and recovery (88.8-99.5% at 10, 100, and 200 ng/mL, n = 3). Seventeen carbonated beverage samples were tested (n = 2) in this study including 13 dark-colored beverage samples with different flavors and varieties and 4 light-colored beverage samples. Three target analytes were quantified in these samples with concentrations in the range from 284 to 644 ng/mL for 4-MI and from 706 to 4940 ng/mL for HMF. THI was detected in only one sample at 6.35 ng/mL.  相似文献   

20.
Aflatoxins are a group of highly toxic fungal secondary metabolites that occur in Aspergillus species and may contaminate foodstuffs and feeds. Two different anti-aflatoxin B(1) antibodies were examined to develop a surface plasmon resonance (SPR)-based immunoassay to aflatoxin B(1). A conjugate consisting of aflatoxin B(1)-bovine serum albumin (BSA) was immobilized on the dextran gel surface. Competition between immobilized aflatoxin B(1) conjugate and free aflatoxin B(1) in solution for binding to antibody injected over the surface formed the basis for the assay. Regeneration of the antibody from the immobilized conjugate surface is essential for the development of such an inhibitive immunoassay. Problems were encountered with the regeneration of the sensor surface, due to the high-affinity binding of the antibodies. Conventional regeneration solutions consisting of low concentrations of NaOH and HCl worked to a degree, but regeneration was at the expense of the integrity of the immobilized conjugate. A polyclonal anti-aflatoxin B(1) antibody was produced and was found to be regenerable using an organic solution consisting of 1 M ethanolamine with 20% (v/v) acetonitrile, pH 12.0. This combined high ionic strength and extreme pH, as well as chaotrophic properties and allowed the development of an inhibitive immunoassay. The assay had a linear range of 3.0-98.0 ng mL(-1) with good reproducibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏