首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 783 毫秒
1.
The purpose of this study was to evaluate the feasibility, safety, and efficacy of transcatheter closure in dogs with a congenital perimembranous ventricular septal defect (VSD) by using a detachable coil. No dogs showed any symptoms, and results of chest X-rays and ECGs were normal. The diameters of VSD ranged from 2 to 4 mm on echocardiogram. The defect was 2-2.5 mm from the aortic valve. A detachable coil (size 5 mm with 5 loops) designed for patent ductus arteriosus was delivered via the transarterial route. The device was successfully employed in all dogs. A minimal residual shunt was observed in all dogs even though Qp/Qs decreased. Hemolysis and a rate-dependent right-bundle branch block were observed in 1 dog, but there was no clinical significance. No major complication was noted. Pathologic examination after 1 year revealed that the coils were covered with tissue without significant damage to the His-Purkinje conduction system. In conclusion, transcatheter closure of a small perimembranous VSD with a detachable coil can be achieved without major complications or significant pathologic damage at the lesion site.  相似文献   

2.
A 4-month-old male French Bulldog weighing 5.0 kg (11 lb) was referred for a heart murmur. A grade 3/6 systolic murmur was detected at the left heart base and a grade 4/6 systolic murmur was detected at the right heart base. By use of color-flow Doppler ultrasonography and cardiac catheterization, a diagnosis of supracristal ventricular septal defect (VSD) with accompanying aortic regurgitation was made. Percutaneous transcatheter coil embolization was used to close the VSD. Because residual shunt was detected via echocardiography after coil implantation, the residual shunt was followed periodically via echocardiography to detect spontaneous closure of the VSD. Volume overload in the left ventricle was detected in the dog 131 days after admission. Additional coils were placed 137 days after admission. Hemolysis resulting in hemoglobinuria was detected, but this complication was mild. In the dog of this report, results of coil occlusion for correction of VSD were promising. Thus, coil occlusion should be considered as an alternative treatment for VSD in dogs.  相似文献   

3.
Background: Transcatheter atrial septal defect (ASD) closure in the dog was first reported in 2005.
Objectives: Describe the technique and both short- and mid-term outcome of transcatheter ASD closure with the Amplatzer® atrial septal occluder (ASO).
Animals: Thirteen client-owned dogs with ASD.
Methods: Records of the initial 13 dogs in which transcatheter ASD closure was attempted at Texas A&M University were reviewed.
Results: All dogs had hemodynamically relevant septum secundum ASD. Two dogs had concurrent congenital abnormalities. ASOs were deployed in 13 dogs and released in 12. Eleven were released by a right jugular approach and 1 by a transatrial approach through a right lateral thoracotomy. Transthoracic echocardiographic estimates of ASD size were 14.0 ± 5.4 mm (mean ± 1 standard deviation) with a range of 7–22 mm. Accidental right atrial release occurred in 1 dog and embolization after release occurred in 2 dogs. Transcatheter ASD closure was successful in 10 dogs. Transthoracic color Doppler echocardiography the day after ASD closure indicated complete occlusion in 5 dogs, trivial to mild residual shunting in 4 dogs, and moderate residual shunting in 1 dog. Follow-up echocardiograms (mean of 12.4 ± 7.4 months postprocedure) were available for 9 dogs. There was no residual ASD shunting in 6 dogs. In 3 of the 5 dogs with postoperative residual shunting it was judged to be decreased and hemodynamically unimportant relative to the dogs' postoperative evaluations. The mean length of event-free survival in the 10 dogs that underwent successful transcatheter ASD closure was 22.2 ± 10.2 months.  相似文献   

4.
Membranous ventricular septal aneurysm was diagnosed by echocardiography in 17 dogs and three cats. The aneurysm appeared as a thin membrane protruding into the right ventricle from the margins of a congenital ventricular septal defect (VSD). The aneurysm was intact in nine dogs and two cats and perforated by a small VSD in eight dogs and one cat. Other congenital heart defects were present in seven dogs. In all animals, the aneurysm was an incidental finding observed during echocardiographic examination, and it did not appear to directly cause any cardiac dysfunction.  相似文献   

5.
Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window.  相似文献   

6.
Background: Appropriate device selection for transcatheter occlusion of patent ductus arteriosus (PDA) is essential to procedural success. Objectives: To determine if transesophageal echocardiography (TEE) influences device selection for PDA occlusion and to report benefits, limitations, and complications associated with TEE. Animals: Twenty‐two client‐owned dogs with left‐to‐right shunting PDA. Methods: PDA dimensions were obtained via transthoracic echocardiography (TTE) and then TEE followed by angiography. Based solely on information from TTE and angiography, an initial device type and size were selected. After initial device selection, TEE measurements were disclosed and changes in device selection were recorded. After device release, angiography, TEE, or both were performed to assess occlusion. Results: An Amplatz canine duct occluder (ACDO) was securely positioned and released in 21 dogs and an embolization coil was deployed in 1 dog. Based on TEE evaluation, initial selected device type was unchanged but ACDO size was changed in 3 dogs. TEE was utilized throughout the procedure allowing real time visualization of device deployment, release and assessment of closure in 17 dogs. No complications occurred related to TEE. Complete PDA closure was achieved in all dogs. Conclusions and Clinical Importance: TEE provided anatomic information regarding PDA morphology that closely approximated angiographic ductal dimensions while aiding in device deployment, release and confirmation of closure. We conclude that TEE provides complementary anatomical and intraprocedural information and is well tolerated in dogs.  相似文献   

7.
A left-to-right shunting muscular ventricular septal defect (VSD) was diagnosed in a 4-month-old, female, 1.8 kg Bichon Frise – poodle mix dog. Echocardiographic evidence of cardiac remodeling, calculated pulmonary blood flow (Qp) to systemic blood flow (Qs) ratio of 2.8, and radiographic evidence of pulmonary edema supported the diagnosis of a hemodynamically important VSD. Using a combination of surgery and interventional catheter-based techniques to approach the VSD through the right ventricle, the VSD was occluded with an Amplatzer® Duct Occluder (ADO) II device. The ADO II is a low profile, flexible device originally developed for patent ductus arteriosus closure in humans that has been used to close muscular and perimembranous VSD in children. This report describes the hybrid procedure and imaging that was essential for successful occlusion of the VSD in this dog.  相似文献   

8.
A 6‐month old female alpaca cria presented to The Ohio State University for evaluation of a cardiac murmur. Echocardiography revealed a left‐to‐right shunting patent ductus arteriosus, a restrictive left‐to‐right shunting perimembranous ventricular septal defect, and secondary moderate left atrial and ventricular dilation. Aortic root angiography demonstrated a type IIA patent ductus arteriosus (PDA). Interventional closure of the PDA was successfully performed, without complication, using an Amplatz canine duct occluder. This case report describes the materials and methods used for interventional closure of a PDA in an alpaca cria.  相似文献   

9.
Two dogs with severe dysplastic pulmonary valve stenosis and right-to-left shunting defects (patent foramen ovale, perimembranous ventricular septal defect) underwent palliative stenting of the right ventricular outflow tract and pulmonary valve annulus using balloon expandable stents. One dog received 2 over-lapping bare metal stents placed 7 months apart; the other received a single covered stent. Both procedures were considered technically successful with a reduction in the transpulmonary valve pressure gradient from 202 to 90 mmHg in 1 dog and from 168 to 95 mmHg in the other. Clinical signs of exercise intolerance and syncope were temporarily resolved in both dogs. However, progressive right ventricular concentric hypertrophy, recurrent stenosis, and erythrocytosis were observed over the subsequent 6 months leading to poor long-term outcomes. Stenting of the right ventricular outflow tract is feasible in dogs with severe dysplastic pulmonary valve stenosis, though further study and optimization of the procedure is required.  相似文献   

10.
BACKGROUND: Per-catheter patent ductus arteriosus (PDA) occlusion in dogs with devices intended for humans is associated with technical difficulties, high rates of procedure abandonment, device migration, and residual ductal flow. HYPOTHESIS: Use of a custom-made canine duct occluder (Amplatz Canine Duct Occluder, ACDO) would be feasible in dogs of varying weights and somatotypes and effective in occluding a wide range of PDA shapes and sizes. ANIMALS: Eighteen client-owned dogs of various breeds with PDA. Weights ranged from 3.8 to 32.3 kg (median, 17.8 kg), and angiographic minimal ductal diameters ranged from 1.1 to 6.9 mm (median, 3.7 mm). Ductal morphologies included types IIA, IIB, and III. METHODS: Per-catheter PDA occlusion with the ACDO was performed in all dogs. Persistent or recurrent ductal flow was assessed at the end of the procedure by angiography and at 1 day, 3 months, and >or=12 months after the procedure by echocardiography. RESULTS: Successful ACDO placement was achieved in all 18 dogs. One dog required a 2nd procedure with a larger ACDO after the 1st device migrated to the pulmonary vasculature. Complete occlusion was confirmed in 17 of 18 dogs during the procedure, as well as at 1 day and 3 months after the procedure, and in 12 of 13 dogs evaluated at >or=12 months after the procedure. CONCLUSIONS AND CLINICAL IMPORTANCE: Per-catheter PDA occlusion in dogs with the ACDO is feasible and effective in dogs of a wide range of weights and somatotypes and with PDAs of varying shapes and sizes.  相似文献   

11.
Perimembranous ventricular septal defect is a common congenital heart disease in the dog. It can partially or completely close with age by development of a membranous ventricular septal aneurysm. Aortic endocarditis is a reported complication of ventricular septal defect and membranous ventricular septal aneurysm in human beings. This report describes a case of aortic endocarditis associated with a membranous ventricular septal aneurysm perforated by a small ventricular septal defect in a boxer dog.  相似文献   

12.
ObjectiveTo describe the characteristics and outcomes of transcatheter patent ductus arteriosus (PDA) occlusion after incomplete or aborted surgical ligation in dogs and cats.AnimalsTwelve client-owned animals (11 dogs and one cat).Materials and methodsThis retrospective study describes data from animals with aborted or incomplete surgical PDA ligation that subsequently underwent transcatheter closure using endovascular methods. Patient demographics, reason for incomplete or aborted surgery, complications, and method of transcatheter occlusion were recorded. Data are presented as mean ± standard deviation or median (interquartile range), where appropriate.ResultsFor all cases, median age at surgery was 12.2 months (4.9–15.1 months) and at catheterization was 15.4 months (8.9–21.9 months), with 79 days (29–209 days) between surgical and interventional procedures. Median weight at catheterization was 4.5 kg (2.5–12.6 kg). Reasons for failed surgical ligation included hemorrhage during ductal dissection in seven dogs, residual flow in four dogs, and inability to identify the ductus in one cat. Transcatheter closure was successfully performed using a canine duct occluder in eight dogs, transarterial coil embolization in two dogs, and transvenous coil embolization in one dog and one cat. Metallic hemoclips partially obscured angiographic findings in three cases with prior surgical hemorrhage but did not prevent transcatheter closure. In all cases, ductal flow was successfully attenuated, with no or trace residual shunting on angiography and complete occlusion the following day on echocardiography.ConclusionsWhen surgery is unsuccessful, either owing to hemorrhage or residual flow, transcatheter closure of PDA is feasible, even in small patients.  相似文献   

13.
Ventricular septal defects are a relatively common congenital cardiac disease that, when severe, can be associated with substantial morbidity and mortality. Several minimally invasive methods of repair have been described in the human literature. This report describes the first case of percutaneous closure of a naturally occurring muscular septal defect using an Amplatzer® occluder in a dog affected by concurrent pulmonic stenosis. Based on this experience catheter-based occlusion of muscular ventricular septal defects is a feasible option in dogs. Further studies are necessary to identify the attributes and limitations of the technique.  相似文献   

14.
This study was designed to evaluate the feasibility and limitations of transcatheter embolization coil occlusion of patent ductus arteriosus in dogs using a carotid artery approach. Seven dogs examined at the University of California, Davis Veterinary Medical Teaching Hospital in 2002-2003 for evaluation of heart disease had congenital patent ductus arteriosus diagnosed by characteristic physical, electrocardiographic, radiographic, and anatomic and Doppler echocardiographic findings. Dogs were anesthetized for transesophageal echocardiography and transcatheter coil embolization of the ductus via the right external carotid artery. Coil embolization was achieved in all seven cases, using one to four detachable embolization coils. There were no major complications. Minor complications occurred in two dogs (additional coils placed using a femoral arterial approach and coil embolization of a left femoral artery branch). One dog was examined only 24 h post-operatively and had no murmur and trivial residual ductal flow by Doppler echocardiography. The other 6 dogs were clinically healthy when examined up to three years post-intervention. One dog had a very soft continuous murmur and mild residual ductal flow; the other five had no audible continuous murmur, with only one dog having trivial residual ductal flow identified by Doppler echocardiography. Although technically challenging, coil embolization via the carotid artery is a viable alternative approach for transcatheter closure of patent ductus arteriosus in some dogs.  相似文献   

15.
Our aim was to compare plastinated sections of the canine heart with corresponding two-dimensional (2D) echocardiographic images. Thirteen dog hearts were fixed by dilation and then processed by the S10 silicon plastination method (Biodur). Two dogs without evidence of cardiac disease were imaged using 2D echocardiography so as to obtain a complete series of the standard right and left parasternal images, which were compared with corresponding plastinated slices obtained by knife sectioning of the hearts. The plastinated slices revealed the internal anatomy of the heart with great detail and were particularly useful to display the spatial relationship between complex anatomic structures. The plastinated slices corresponded accurately with the echocardiographic images. Because of the dilation of the right heart during the fixation process, it was not possible to obtain plastinated specimens in ventricular systole. This paper may be a reference atlas for assisting 2D echocardiography interpretation.  相似文献   

16.
Transcatheter occlusion of patent ductus arteriosus (PDA) using an Amplatz® Canine Duct Occluder (ACDO) is routinely performed in dogs. Pulmonary embolization of the device is a rarely reported complication of this procedure. We report here the first two cases of successful transcatheter retrieval of an embolized ACDO. An 8-month-old, 21-kg, German shepherd (case 1) was referred for pulmonary edema secondary to a large PDA with left-to-right shunting. After medical stabilization, an emergency procedure for PDA closure was recommended. An 8-mm ACDO was deployed under general anesthesia. The device was released after confirming its stability with a gentle tug test but migrated into the pulmonary trunk. A 10-mm ACDO was subsequently successfully deployed and released. Vascular access was then obtained from the right jugular vein so that a vascular snare could be used to capture the ACDO waist and pull it back toward the right ventricle and then the right atrium. It was then removed through the jugular vein. The dog recovered uneventfully and was discharged after confirmation of complete ductal occlusion. The same complication occurred in a second case (case 2, asymptomatic 6-month-old, 7.9-kg, cocker spaniel), and a similar procedure was used to successfully retrieve the embolized device. Both dogs are still doing well 9 and 21 months, respectively, after the procedure. These cases illustrate that transcatheter retrieval of ACDO devices embolized in the pulmonary artery using vascular snares is technically feasible in the dog.  相似文献   

17.
A 6.5-year-old male Border Collie presented for transcatheter closure of an atrial septal defect due to exercise intolerance and cyanosis while working and training at altitude. A small, left-to-right shunting secundum atrial septal defect was confirmed with no evidence of significant right-sided volume overload. Pulmonary hypertension with subsequent right-to-left interatrial shunting occurring during exercise at high altitude was suspected and prompted the closure of the defect due to the dog's continued athletic requirements. The anatomy of the defect prompted use of a patent foramen ovale occluder rather than an atrial septal defect occluder, which was deployed using a combination of fluoroscopic and transesophageal echocardiographic guidance. The owner did not report continued exercise intolerance or cyanosis and the dog's lifestyle and residence at altitude was unchanged.  相似文献   

18.
Background: Transarterial ductal occlusion with the Amplatzer vascular plug was first reported in dogs by Hogan et al in 2005. Hypothesis: Use of the Amplatzer vascular plug is a safe, efficacious method of patent ductus arteriosus (PDA) occlusion. Animals: Thirty‐one client‐owned dogs with PDA. Methods: Records of 31 dogs in which transarterial occlusion of PDA with an Amplatzer vascular plug was attempted were reviewed. Results: All dogs had a type II PDA, with 27 dogs having type IIA morphology and 4 dogs having type IIB morphology. Appropriate device deployment was achieved in 29 of 31 dogs. Postdeployment angiography in 21 dogs documented complete occlusion in 10 dogs, trivial residual flow in 5 dogs, mild residual flow in 2 dogs, moderate residual flow in 3 dogs, and severe residual flow in 1 dog. Transthoracic color Doppler echocardiography documented complete occlusion in 22 dogs, whereas 2 dogs had trivial residual flow, 2 dogs had mild residual flow, 2 dogs had mild to moderate residual flow, and 1 dog had severe residual flow. Of the 7 dogs with residual flow, 2 had complete occlusion 2–4 months postoperatively, 1 had moderate residual flow 1 month postoperatively, and 4 were lost to follow‐up. One dog required a larger device than was able to be deployed through the largest sheath placed in the femoral artery. Pulmonary embolization of the device occurred in 1 dog. Conclusion: We conclude that ductal occlusion with an Amplatzer vascular plug is a safe and efficacious therapy for PDA in dogs.  相似文献   

19.
The Amplatz® canine duct occluder (ACDO) is a nitinol mesh device with a short waist that separates a flat distal disc from a cupped proximal disc. The device is designed to conform to the morphology of the canine patent ductus arteriosus (PDA). PDA dimensions are determined by angiography, and a guiding catheter is advanced into the main pulmonary artery via the aorta and PDA. An ACDO with a waist diameter approximately twice the angiographic minimal ductal diameter (MDD) is advanced via the catheter using an attached delivery cable until the flat distal disc deploys within the main pulmonary artery. The partially deployed ACDO, guiding catheter, and delivery cable are retracted until the distal disc engages the pulmonic ostium of the PDA. With the delivery cable stabilized, the catheter is retracted to deploy the waist across the pulmonic ostium and cupped proximal disc within the ductal ampulla. Tension on the delivery cable is released, and correct ACDO positioning and stability are confirmed by observing that the device assumes its native shape, back-and-forth maneuvering of the delivery cable, and a small contrast injection made through the guiding catheter. The delivery cable is detached and removed with the guiding catheter. To assess for any residual ductal flow, an angiogram is performed at the conclusion of the procedure, followed by Doppler echocardiography at 1 day and 3 months post-procedure. PDA occlusion in dogs with the ACDO is straightforward and extremely effective across a wide range of body weights, somatotypes, MDDs, and ductal morphologies.  相似文献   

20.
OBJECTIVE: To compare right atrium incision (RAI) and right ventricular outflow incisions (RVI) for surgical repair of membranous ventricular septal defect (VSD) facilitated by cardiopulmonary bypass (CPB). STUDY DESIGN: Retrospective study. ANIMALS: Dogs (n=10) with VSD. METHODS: Medical records of dogs that had VSD repair were reviewed. Membranous VSD without any malformation and abnormality was confirmed on several clinical examinations and by angiocardiography. RAI (5 dogs) and RVI (5 dogs) was used for VSD access and repair facilitated by CPB. Procedure comparison was by surgical duration, postoperative recovery period, and occurrence of postoperative arrhythmia. RESULTS: Duration of surgery was similar for RAI and RVI; however, postoperative recovery time was significantly reduced with RAI. Significant moderate operative damage occurred with right atrium incision. CONCLUSIONS: Right atrium incision was more effective than RVI for repair of membranous VSD using CPB. CLINICAL RELEVANCE: RAI should be considered in preference to RVI for repair of membranous VSD using CPB.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号