首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   259篇
  免费   0篇
畜牧兽医   259篇
  2009年   2篇
  1998年   1篇
  1994年   29篇
  1993年   65篇
  1991年   32篇
  1988年   28篇
  1987年   1篇
  1986年   65篇
  1985年   35篇
  1981年   1篇
排序方式: 共有259条查询结果,搜索用时 46 毫秒
51.
Caudal Sartorius Muscle Flap in the Dog   总被引:1,自引:0,他引:1  
An anatomic study was performed on canine cadavers to define the blood supply to the caudal sartorius muscle. The vascular supply to this muscle was segmental with the saphenous artery and vein providing a distal vascular pedicle. Anastomotic channels existed between distal and proximal capillary beds within the muscle belly. This anatomic information was used to determine the feasibility of performing caudal sartorius muscle flaps in dogs. The caudal sartorius muscle was transposed to the medial tibial region in four dogs. The muscle flap was based on a singular vascular pedicle of the saphenous artery and vein. The muscle transpositions were all successful on day 14 as evidenced by gross appearance and results of histologic examination. Grossly, the muscles were well adhered to the recipient sites and were covered by connective tissue. Histologically, the specimens were characterized by viable skeletal muscle fibers, large amounts of granulation tissue, varying degrees of inflammatory response, and small foci of myocyte necrosis (2 cases). Seroma formation was a consistent postoperative complication.  相似文献   
52.
Five configurations of pins or screws interconnected with polymethylmethacrylate (PMMA) were applied to isolated canine lumbar spines (L2 to L5) in which a complete fracture-luxation had been produced at L3 to L4. Twenty-five repaired spines and five intact control spines were subjected to four-point bending and tested once to failure in ventral flexion. The purpose of this study was to determine the effects of pin number, pin angle, and use of 3.5-mm cortical bone screws instead of smooth 3.2-mm diameter pins on rigidity and ultimate strength of spinal fractures repaired by the implant-PMMA fixation technique. Bending moment versus the angular deformation curves were recorded. Rigidity, bending moment at 10° angular deformation, moment at failure, and deformation at failure of each type of fixation were compared using analysis of variance. Spinal segments stabilized with eight pin-PMMA fixation had significantly greater rigidity and strength at failure than four pin-PMMA fixations ( P < .05). Furthermore, spinal segments stabilized with eight pins angled away from the fracture failed at significantly greater bending moment than those with eight pins angled toward the fracture ( P < .05). However, for four-pin fixation, greater strength was achieved by angling pins in the bone toward the fracture site ( P < .05). Screw-PMMA fixations failed by screw bending and were less rigid and weaker at failure than the corresponding configuration of pin-PMMA fixation ( P < .05).  相似文献   
53.
This study compared the severity of ischemic injury to the equine jejunal mucosa caused by arteriovenous obstruction (AVO) or venous obstruction (VO) with that caused by reperfusion after ischemia. The degree of mucosal damage and regeneration was scored according to a modified version of an established light microscopic classification for ischemic injury. Biopsy specimens taken after 3 and 4 hours of obstruction, and after 3 hours of obstruction and 1 hour of reperfusion, were compared. There were no changes in the severity of mucosal injury (characterized by epithelial sloughing, loss of villus architecture, and necrosis of crypt cells) at 4 hours of ischemia when compared with 3 hours of ischemia. The mucosal injury score increased by one grade in three of six and five of eight segments during reperfusion for the VO and AVO models, respectively; however, only the scores for the AVO model were significantly different from the injury caused by ischemia alone. Modification of reperfusion injury was attempted by the administration of intravenous (IV) allopurinol, dimethyl sulfoxide (DMSO), or intraluminal oxygen insufflation at the time of release of the AVO and VO. Treatments did not significantly alter either the severity of injury noted after 1 hour of reperfusion or the degree of mucosal regeneration after 48 hours of reperfusion. In this group of ponies, the severity of mucosal damage was greater after 1 hour of reperfusion for both AVO and VO.  相似文献   
54.
Arthroscopic examination of structures within the plantar pouch of the tarsocrural joint was accomplished via portals in both the plantaromedial and plantarolateral aspects of the joint. Flexion and extension of the tarsus while examining the joint through either portal allowed observation of the proximal and plantar aspects of the lateral and medial trochlear ridges, the trochlear groove, the caudal aspect of the distal tibia, and the deep digital flexor tendon (DDFT) in its sheath. From a plantarolateral portal, the plantar talocalcaneal ligament and the plantar aspect of the lateral malleolus could be observed. The caudal aspect of the medial malleolus could not be observed with flexion or extension of the joint from a plantaromedial portal, but in some horses, the caudal aspect of the lateral malleolus could be observed. The dorsolateral and dorsomedial aspects of the plantar pouch were best examined from a portal on the ipsilateral side of the joint. An instrument portal opposite either arthroscope portal allowed access to most regions of the joint except the abaxial surface of the trochlear ridge opposite the instrument.  相似文献   
55.
Evaluation of Canine-Derived Fibrin Sealant as a Hemostatic Agent   总被引:1,自引:0,他引:1  
The purpose of this study was to determine whether canine-derived fibrinogen concentrate applied with bovine thrombin was a safe and effective topical hemostatic agent. A canine liver biopsy model was selected to test this product. Cryoprecipitate was prepared from frozen canine plasma using two freeze/thaw/centrifugation cycles. Six healthy adult dogs (weighing more than 18 kg) were used in the fibrin sealant study, and an additional three dogs were used as controls for the liver biopsy. A 1 × 3 cm liver biopsy specimen was obtained, digital pressure was applied to reduce bleeding, and the fibrinogen concentrate was immediately sprayed on the bleeding surface simultaneously with bovine thrombin (1,000 IU/mL). The mean ± standard error of the mean (SEM) blood pressure at time of biopsy was 98 ± 9 mm Hg, and the rate of hemorrhage from the cut liver edge was 8.0 ± 1.1 mL/min. The total blood loss during fibrin sealant application was 37 ± 9 mL and total time for hemostasis was 5.5± 1.3 minutes. There was no additional hemorrhage after application of the fibrin sealant. In the three control dogs, fibrin sealant was not applied and only digital compression was used to decrease hemorrhage. Before digital compression, the rate of hemorrhage from the cut liver edge was 13.1 ±3.1 mL/min. Bleeding had not stopped after 10 minutes of compression and the mean postcompression rate of hemorrhage was 4.0 ± 2.6 mL/min. Signs of secondary bleeding after fibrin sealant was applied were not evident during the immediate postoperative period or over the next 14 days. The coagulation profile, alanine amino transferase (ALT), alkaline phosphatase (AP), and bile acids were not significantly different on day 14 from preoperative values, suggesting that the liver was only mildly affected. The dogs were euthanatized and gross and histological examinations of the biopsy site were performed on day 14. There were minimal or no adhesions at the biopsy site. In all dogs, the hepatic capsule was less than 1 mm thick and histological signs of secondary bleeding, hepatocellular damage, thrombosis, infection, or inflammation were not observed. In this study, canine-derived fibrin sealant was a safe and effective topical hemostatic agent.  相似文献   
56.
A retrospective study of 14 dogs with one or more acetabular fractures stabilized with an acetabular plate was conducted. Twelve of the 14 dogs had additional orthopedic injuries. Follow-up was longer than 6 months. Eleven dogs were evaluated by assessment of radiographs, lameness, mid-thigh circumference, coxofemoral joint range of motion, crepitus, and pain. Varying degrees of osteoarthrosis were noted radiographically at follow-up. Ten of 12 dogs examined had occasional or no clinical lameness. In 10 of 12 dogs, mid-thigh circumference was less on the limb that sustained the acetabular fracture. Nonunion was diagnosed in one plated acetabulum in which two screws had broken. A return to normal or nearly normal function was observed when there were no more than two orthopedic injuries.  相似文献   
57.
Magnetically elicited transcranial motor evoked potentials (MEPs) were studied in 37 dogs with type 1 intervertebral disc (IVD) disease. The waveforms were recorded from both cranial tibial muscles before and after surgery. The latencies and amplitudes obtained were compared to those of a control population (n = 14). MEPs were recordable in all dogs with mild or no neurologic deficits, but they were recordable in only 50% of ambulatory dogs that were severely ataxic. MEPs could not be elicited from nonambulatory dogs. There was a significant attenuation of the amplitudes in all clinical cases, even if the dogs demonstrated back pain alone. Significantly prolonged latencies were associated with neurologic deficits. MEPs were not good predictors of neurologic recovery. The responses obtained from the side where the disc material was found were not different from those recorded from the opposite side. MEPs were very sensitive to lesions of the spinal cord, as indicated by the significant changes in the waves in patients with mild or no neurologic deficits and in the loss of response in dogs that still demonstrated purposeful movement. Neurologic exams provided more accurate diagnoses and prognoses than did MEPs in dogs with IVD disease.  相似文献   
58.
To facilitate blood collection from blood donor dogs, arteriovenous fistulas were established between the common carotid arteries and external jugular veins in five adult dogs. Twelve to 16 mm, side-to-side anastomoses were created using simple interrupted 6–0 polypropylene sutures. Starting 1 month after the surgical procedure, 500 ml of blood was collected from each dog as required. Electrocardiography, thoracic radiography, and cardiac output and rate were used to monitor cardiac changes. Blood flow characteristics, and proliferative and dystrophic cellular changes occurring in the vessels were documented in one dog.
The mean blood collection times were 2 minutes and 45 seconds from the fistula site and 9.0 minutes from the opposite jugular vein. Ventricular hypertrophy and myocardial changes were observed on electrocardiogram in two dogs, and radiographic evidence of pulmonary hypertension was noted in three dogs. Reversed blood flow was documented in the common carotid artery and external jugular vein distal to the arteriovenous fistula. Four dogs were still in use as blood donors 1 to 1 1/2 years after establishment of the fistulas. Clinical signs of congestive heart failure were not observed.  相似文献   
59.
An anatomic analysis of retrograde and normograde intramedullary (IM) pinning of proximal, midshaft, and distal femoral fractures was performed in 28 canine cadavers. For all fracture locations, normograde pins were significantly more cranial in the middle gluteal muscle than retrograde pins (p less than 0.01). There was no significant difference between pinning techniques in craniocaudal position of the IM pin in the superficial gluteal muscle. In distal fractures, normograde pins were placed significantly more lateral than retrograde pins in the superficial gluteal muscle (p less than 0.01). One of 15 normograde pins and 9 of 13 retrograde pins were located in the medial half of the trochanteric fossa. Normograde pins were significantly more lateral in the trochanteric fossa than were retrograde pins in midshaft fractures (p less than 0.01). Normograde pins were significantly (p less than 0.01) farther from the sciatic nerve than retrograde pins when the hip was positioned at coxofemoral flexion angles of 85 degrees in midshaft and 110 degrees in distal fractures. Seven of 13 retrograde pins, but none of 15 normograde pins, contacted the sciatic nerve. Normograde pinning of the femur may be less likely to induce sciatic nerve injury, particularly in midshaft and distal fractures.  相似文献   
60.
Chlorhexidine diacetate and povidone-iodine were evaluated for fibroblast toxicity on a primary line of canine embryonic fibroblasts, and for bactericidal efficacy against Staphylococcus aureus. The cultured fibroblasts or S. aureus were exposed for 30 minutes to incremental dilutions of 0.5 and 0.0005% chlorhexidine diacetate, 5.0 to 0.05% povidone-iodine, or physiologic buffered saline as a control. To determine survival, fibroblasts were trypsinized and counted; S. aureus colonies were counted on brain-heart infusion agar. Survival for both groups was expressed by calculating the number of living cells in test dilutions as a percentage of the number in control cultures. Fibroblast survival occurred at chlorhexidine concentrations less than 0.013% and at povidone-iodine concentrations less than 0.5% (p less than 0.05). Significant S. aureus survival (p less than 0.05) was noted at chlorhexidine concentrations less than 0.05% and povidone-iodine concentrations less than 1.0%. These data showed that all bactericidal concentrations of chlorhexidine diacetate and povidone-iodine were lethal to canine embryonic fibroblasts in vitro, whereas non-lethal concentrations allowed significant bacterial survival.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号