全文获取类型
收费全文 | 105篇 |
免费 | 24篇 |
专业分类
林业 | 2篇 |
畜牧兽医 | 126篇 |
园艺 | 1篇 |
出版年
2023年 | 4篇 |
2020年 | 4篇 |
2019年 | 2篇 |
2018年 | 7篇 |
2017年 | 8篇 |
2016年 | 6篇 |
2015年 | 4篇 |
2014年 | 7篇 |
2013年 | 5篇 |
2012年 | 4篇 |
2010年 | 1篇 |
2009年 | 5篇 |
2008年 | 2篇 |
2007年 | 2篇 |
2006年 | 1篇 |
2005年 | 1篇 |
2004年 | 2篇 |
2003年 | 6篇 |
2002年 | 2篇 |
2001年 | 4篇 |
1999年 | 2篇 |
1998年 | 4篇 |
1997年 | 1篇 |
1996年 | 3篇 |
1995年 | 4篇 |
1994年 | 1篇 |
1993年 | 4篇 |
1992年 | 4篇 |
1991年 | 3篇 |
1990年 | 4篇 |
1989年 | 5篇 |
1988年 | 2篇 |
1987年 | 1篇 |
1986年 | 1篇 |
1980年 | 1篇 |
1979年 | 2篇 |
1978年 | 1篇 |
1974年 | 2篇 |
1972年 | 4篇 |
1971年 | 1篇 |
1969年 | 2篇 |
排序方式: 共有129条查询结果,搜索用时 15 毫秒
81.
82.
VL Grillo KE Arzey PM Hansbro AC Hurt S Warner J Bergfeld GW Burgess B Cookson CJ Dickason M Ferenczi T Hollingsworth MDA Hoque RB Jackson M Klaassen PD Kirkland NY Kung S Lisovski MA O'Dea K O'Riley D Roshier LF Skerratt JP Tracey X Wang R Woods L Post 《Australian veterinary journal》2015,93(11):387-393
83.
84.
Marco A. Lima DVM Carmen Calles DVM Juan R. Lima DVM Maria F. Martin PD PhD Veronica Crisostomo DVM Francisco J. Hernandez MD PhD Rafael Barrera DVM PhD Jesus Uson DVM PhD 《Veterinary radiology & ultrasound》2002,43(2):171-177
The aim of this study was to use ultrasonography to assess an experimental carotid arteriotomy followed by end-to-end anastomosis in the lamb. Animals were subjected to an experimental surgical procedure consisting of a right carotid artery arteriotomy and subsequent end-to-end anastomosis with nonpenetrating metallic clips. Left side arteries were used as control. Duplex ultrasonography was performed postoperatively to assess the evolution of the experimental anastomosis. Measurements were made on the right carotid to assess blood flow, peak systolic velocity, and end diastolic velocity, as well as arterial diameter. Animals were periodically checked during the six-month postoperative period. Operated vessels appeared normal during follow up, with pulsatile movements and size similar to non operated carotid arteries. A hyperechoic band, perpendicular to the vessel main axis, was seen on the longitudinal image in operated arteries, but not in the control group. This band corresponded to the anastomosis area, where the clips were positioned. No image suggestive of thrombosis was observed in any operated artery, and blood flow was maintained through the experiment. Finally, a decrease of vessel lumen diameter was evidenced at the level of the anastomosis during the first 30 postoperative days, but it was not present after the 90th postsurgical day. Duplex ultrasonography is a useful imaging technique for the assessment of anatomical details, acoustical properties of the vascular lumen, and study of the intimal surface and vessel wall in growing arteries subjected to surgery. Metallic clips as suturing technique in arterial anastomosis allow for normal vascular growth, as shown by the evolution of flow velocity and vessel diameter. 相似文献
85.
86.
Differentiation of avian infectious bronchitis virus serotypes by immunofluorescence 总被引:1,自引:0,他引:1
P D Lukert 《Avian diseases》1969,13(4):847-852
87.
KM Ketzner AA Stewart CR Byron M Stewart EM Gaughan PD Vanharreveld JD Lillich 《Australian veterinary journal》2009,87(9):363-368
Objective Describe the use of a phalangeal cast as treatment for wounds in the pastern and foot region of horses. Secondly, to evaluate the healing and soundness of horses treated with phalangeal casts.
Design Retrospective study of 49 horses.
Procedures Medical records of 49 horses that were treated with a phalangeal cast for 50 cases of wounds in the pastern and foot region at equine referral hospitals from 1995 to 2006 were reviewed and follow-up information was obtained.
Results Treatment consisted of wound debridement, lavage, wound closure (28 wounds), cast application and antibiotics (84%). At follow-up, the majority of horses were sound (42 of 47 wounds, 89.4%), three horses were still lame and one horse was euthanased because of persistent lameness. Three horses were lost to follow-up. There was no statistical difference between the outcomes of horses treated acutely (<24 h) or after a 24-h delay. Similarly, the involvement of synovial structures in the wound did not significantly influence outcome.
Conclusions In this study, wounds involving the pastern and foot that were treated with a phalangeal cast carried a good prognosis for soundness (89.4%) and cosmetic healing (89.5%). The phalangeal casts were well-tolerated and effective. 相似文献
Design Retrospective study of 49 horses.
Procedures Medical records of 49 horses that were treated with a phalangeal cast for 50 cases of wounds in the pastern and foot region at equine referral hospitals from 1995 to 2006 were reviewed and follow-up information was obtained.
Results Treatment consisted of wound debridement, lavage, wound closure (28 wounds), cast application and antibiotics (84%). At follow-up, the majority of horses were sound (42 of 47 wounds, 89.4%), three horses were still lame and one horse was euthanased because of persistent lameness. Three horses were lost to follow-up. There was no statistical difference between the outcomes of horses treated acutely (<24 h) or after a 24-h delay. Similarly, the involvement of synovial structures in the wound did not significantly influence outcome.
Conclusions In this study, wounds involving the pastern and foot that were treated with a phalangeal cast carried a good prognosis for soundness (89.4%) and cosmetic healing (89.5%). The phalangeal casts were well-tolerated and effective. 相似文献
88.
KATHARINA U. HEDIGER DVM STEPHEN J. FERGUSON DVM PhD PHILIPPE GEDET Dipl. Ing. RE BUSATO DVM MSc PD FRANCK FORTERRE DVM Diplomate ECVS SAMUEL ISLER DVM RETO BARMETTLER DVM JOHANN LANG DVM Diplomate ECVDI 《Veterinary surgery : VS》2009,38(7):874-880
Objective— To determine stiffness and load–displacement curves as a biomechanical response to applied torsion and shear forces in cadaveric canine lumbar and lumbosacral specimens.
Study Design— Biomechanical study.
Animals— Caudal lumbar and lumbosacral functional spine units (FSU) of nonchondrodystrophic large-breed dogs (n=31) with radiographically normal spines.
Methods— FSU from dogs without musculoskeletal disease were tested in torsion in a custom-built spine loading simulator with 6 degrees of freedom, which uses orthogonally mounted electric motors to apply pure axial rotation. For shear tests, specimens were mounted to a custom-made shear-testing device, driven by a servo hydraulic testing machine. Load–displacement curves were recorded for torsion and shear.
Results— Left and right torsion stiffness was not different within each FSU level; however, torsional stiffness of L7-S1 was significantly smaller compared with lumbar FSU (L4-5–L6-7).
Ventral/dorsal stiffness was significantly different from lateral stiffness within an individual FSU level for L5-6, L6-7, and L7-S1 but not for L4-5. When the data from 4 tested shear directions from the same specimen were pooled, level L5-6 was significantly stiffer than L7-S1.
Conclusions— Increased range of motion of the lumbosacral joint is reflected by an overall decreased shear and rotational stiffness at the lumbosacral FSU.
Clinical Relevance— Data from dogs with disc degeneration have to be collected, analyzed, and compared with results from our chondrodystrophic large-breed dogs with radiographically normal spines. 相似文献
Study Design— Biomechanical study.
Animals— Caudal lumbar and lumbosacral functional spine units (FSU) of nonchondrodystrophic large-breed dogs (n=31) with radiographically normal spines.
Methods— FSU from dogs without musculoskeletal disease were tested in torsion in a custom-built spine loading simulator with 6 degrees of freedom, which uses orthogonally mounted electric motors to apply pure axial rotation. For shear tests, specimens were mounted to a custom-made shear-testing device, driven by a servo hydraulic testing machine. Load–displacement curves were recorded for torsion and shear.
Results— Left and right torsion stiffness was not different within each FSU level; however, torsional stiffness of L7-S1 was significantly smaller compared with lumbar FSU (L4-5–L6-7).
Ventral/dorsal stiffness was significantly different from lateral stiffness within an individual FSU level for L5-6, L6-7, and L7-S1 but not for L4-5. When the data from 4 tested shear directions from the same specimen were pooled, level L5-6 was significantly stiffer than L7-S1.
Conclusions— Increased range of motion of the lumbosacral joint is reflected by an overall decreased shear and rotational stiffness at the lumbosacral FSU.
Clinical Relevance— Data from dogs with disc degeneration have to be collected, analyzed, and compared with results from our chondrodystrophic large-breed dogs with radiographically normal spines. 相似文献
89.
90.