首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   42篇
  免费   35篇
畜牧兽医   77篇
  2016年   1篇
  2012年   2篇
  2011年   1篇
  2009年   1篇
  2008年   3篇
  2007年   1篇
  2006年   2篇
  2005年   3篇
  2004年   4篇
  2003年   4篇
  2002年   3篇
  2001年   6篇
  1999年   2篇
  1998年   1篇
  1997年   3篇
  1996年   4篇
  1995年   1篇
  1994年   1篇
  1993年   1篇
  1991年   3篇
  1990年   2篇
  1989年   5篇
  1988年   2篇
  1987年   1篇
  1986年   4篇
  1985年   4篇
  1984年   1篇
  1983年   5篇
  1979年   1篇
  1975年   1篇
  1974年   1篇
  1973年   1篇
  1972年   2篇
排序方式: 共有77条查询结果,搜索用时 174 毫秒
41.
The objective of this prospective clinical study was to evaluate the accuracy of pulse oximetry and capnography in healthy and compromised horses during general anesthesia with spontaneous and controlled ventilation. Horses anesthetized in a dorsal recumbency position for arthroscopy (n = 20) or colic surgery (n = 16) were instrumented with an earlobe probe from the pulse oximeter positioned on the tip of the tongue and a sample line inserted at the Y-piece for capnography. The horses were allowed to breathe spontaneously (SV) for the first 20 min after induction, and thereafter ventilation was controlled (IPPV). Arterial blood, for blood gas analysis, was drawn 20 min after induction and 20 min after IPPV was started. Relationships between oxygen saturation as determined by pulse oximetry (SpO2), arterial oxygen saturation (SaO2), arterial carbon dioxide partial pressure (PaCO2), and end tidal carbon dioxide (P(et)CO2), several physiological variables, and the accuracy of pulse oximetry and capnography, were evaluated by Bland–Altman or regression analysis. In the present study, both SpO2 and P(et)CO2 provided a relatively poor indication of SaO2 and PaCO2, respectively, in both healthy and compromised horses, especially during SV. A difference in heart rate obtained by pulse oximetry, ECG, or palpation is significantly correlated with any pulse oximeter inaccuracy. If blood gas analysis is not available, ventilation to P(et)CO2 of 35 to 45 mmHg should maintain the PaCO2 within a normal range. However, especially in compromised horses, it should never substitute blood gas analysis.  相似文献   
42.
OBJECTIVE: To assess accuracy and reliability of open-flow indirect calorimetry in dogs. ANIMALS: 13 clinically normal dogs. PROCEDURE: In phase 1, oxygen consumption per kilogram of body weight (VO2/kg) was determined in 6 anesthetized dogs by use of open-flow indirect calorimetry before and after determination of VO2/kg by use of closed-circuit spirometry. In phase 2, four serial measurements of VO2 and carbon dioxide production (VCO2) were obtained in 7 awake dogs by use of indirect calorimetry on 2 consecutive days. Resting energy expenditure (REE) was calculated. RESULTS: Level of clinical agreement was acceptable between results of indirect calorimetry and spirometry. Mean VO2/kg determined by use of calorimetry before spirometry was significantly greater than that obtained after spirometry. In phase 2, intraclass correlation coefficients (ICC) for REE and VO2 were 0.779 and 0.786, respectively, when data from all 4 series were combined. When the first series was discounted, ICC increased to 0.904 and 0.894 for REE and VO2, respectively. The most reliable and least variable measures of REE and VO2 were obtained when the first 2 series were discounted. CONCLUSIONS AND CLINICAL RELEVANCE: Open-flow indirect calorimetry may be used clinically to obtain a measure of VO2 and an estimate of REE in dogs. Serial measurements of REE and VO2 in clinically normal dogs are reliable, but a 10-minute adaption period should be allowed, the first series of observations should be discounted, multiple serial measurements should be obtained, and REE.  相似文献   
43.
The neuroanatomy of the mammalian visual system has received considerable attention through electrophysiological study of cats and non-human primates, and through neuroimaging of humans. Canine neuroanatomy, however, has received much less attention, limiting our understanding of canine vision and visual pathways. As an early step in applying blood oxygenation level dependant (BOLD) functional magnetic resonance imaging (fMRI) for veterinary use, we compared visual activity in the thalamus and occipital cortex of anesthetized dogs presented with binocular and monocular visual stimuli. Activity in the left and right thalamus and occipital cortex during monocular stimulation was also compared. Six beagles were presented with a vertical grating visual stimulus and scanned at 4 Tesla. Each dog was scanned twice under each of 3 anesthetic protocols (isoflurane, propofol, and fentanyl/midazolam). We found: 1) significant BOLD activation in the lateral geniculate nucleus (LGN) of the thalamus and the occipital cortex; 2) a significantly larger area of activation in the LGN during monocular stimulation than during binocular stimulation; and 3) that activity in the hemisphere contralateral to the stimulus was not significantly greater than that ipsilateral to it.  相似文献   
44.
OBJECTIVES: To determine agreement of cardiac output measured by use of lithium dilution cardiac output (LiDCO) and thermodilution cardiac output (TDCO) techniques in dogs and to determine agreement of low- and high-dose LiDCO with TDCO. ANIMALS: 10 dogs (7 males, 3 females). PROCEDURE: Cardiac output was measured in anesthetized dogs by use of LiDCO and TDCO techniques. Four rates of cardiac output were induced by occlusion of the caudal vena cava, changes in depth of anesthesia, or administration of dobutamine. Lithium dilution cardiac output was performed, using 2 doses of lithium chloride (low and high dose). Each rate of cardiac output allowed 4 comparisons between LiDCO and TDCO. RESULTS: 160 comparisons were determined of which 68 were excluded. The remaining 92 comparisons had values ranging from 1.10 to 12.80 L/min. Intraclass correlation coefficient (ICC) between low-dose LiDCO and TDCO was 0.9898 and between high-dose LiDCO and TDCO was 0.9896. When all LiDCO determinations were pooled, ICC was 0.9894. For determinations of cardiac output < 5.0 L/min, ICC was 0.9730. Mean +/- SD of the differences of TDCO minus LiDCO for all measurements was -0.084+/-0.465 L/min, and mean of TDCO minus LiDCO for cardiac outputs < 5.0 L/min was -0.002+/-0.245 L/min. CONCLUSIONS AND CLINICAL RELEVANCE: The LiDCO technique is a suitable substitute for TDCO to measure cardiac output in dogs. Use of LiDCO eliminates the need for catheterization of a pulmonary artery and could increase use of cardiac output monitoring, which may improve management of cardiovascularly unstable animals.  相似文献   
45.
Ten adult Holstein cows were used in an experiment to determine whether the induction of electroimmobilization was a noxious event. The cows were halter trained and accustomed to being led into a set of stocks. The time taken for the cattle to walk the last ten metres into the stocks was recorded. The heart rate of the cow was recorded for a three minute period prior to a ten second exposure to a high pitched sound (the conditioning stimulus). Measurements were collected for three repetitions and then the cows were assigned to two groups of five. One group was immobilized for 30 seconds using a commercial electroimmobilizer, the other group was not treated. This procedure was repeated ten times over a period of eight days. The cows were then exposed to the conditioning stimulus and their response observed. The treated group took significantly (P less than 0.05) longer to get into the stocks and the regression slopes for heart rate were significantly different from the control group. The treated cows responded to the conditioning stimulus at five and nine months after the end of the conditioning period. Adult Holstein cows regarded electroimmobilization as a noxious event and were very strongly conditioned to this stimulus.  相似文献   
46.
47.
OBJECTIVE: To evaluate the cardiorespiratory and intestinal effects of the muscarinic type-2 (M2) antagonist, methoctramine, in anesthetized horses. ANIMALS: 6 horses. PROCEDURE: Horses were allocated to 2 treatments in a randomized complete block design. Anesthesia was maintained with halothane (1% end-tidal concentration) combined with a constant-rate infusion of xylazine hydrochloride (1 mg/kg/h, i.v.) and mechanical ventilation. Hemodynamic variables were monitored after induction of anesthesia and for 120 minutes after administration of methoctramine or saline (0.9% NaCl) solution (control treatment). Methoctramine was given at 10-minute intervals (10 microg/kg, i.v.) until heart rate (HR) increased at least 30% above baseline values or until a maximum cumulative dose of 30 microg/kg had been administered. Recovery characteristics, intestinal auscultation scores, and intestinal transit determined by use of chromium oxide were assessed during the postanesthetic period. RESULTS: Methoctramine was given at a total cumulative dose of 30 microg/kg to 4 horses, whereas 2 horses received 10 microg/kg. Administration of methoctramine resulted in increases in HR, cardiac output, arterial blood pressure, and tissue oxygen delivery. Intestinal auscultation scores and intestinal transit time (interval to first and last detection of chromium oxide in the feces) did not differ between treatment groups. CONCLUSIONS AND CLINICAL RELEVANCE: Methoctramine improved hemodynamic function in horses anesthetized by use of halothane and xylazine without causing a clinically detectable delay in the return to normal intestinal motility during the postanesthetic period. Because of their selective positive chronotropic effects, M2 antagonists may represent a safe alternative for treatment of horses with intraoperative bradycardia.  相似文献   
48.
The hemodynamic effects of 1.5 minimal alveolar concentration of halothane alone (1.6% end-tidal) and 1.5 minimal alveolar concentration of halothane (1.1% end-tidal concentration) combined with epidurally administered morphine were compared during controlled ventilation in 10 dogs used on 2 occasions and randomly allocated to 2 groups. Arterial blood pressure, cardiac index, stroke volume, left ventricular work, and pulmonary arterial pressure were significantly (P less than 0.05) higher in dogs of the morphine-treated group before administration of morphine. After epidural administration of morphine (0.1 mg/kg of body weight diluted in 0.26 ml of saline solution/kg), hemodynamic changes were not observed, and the aforementioned variables remained significantly (P less than 0.05) higher than values in dogs of the halothane only group. Compared with halothane (1.6%) alone, the reduction in halothane end-tidal concentration (1.1%) associated with epidurally administered morphine is beneficial in maintaining hemodynamic function.  相似文献   
49.
Samples of mucus from the lower trachea were collected from 53 horses with chronic obstructive pulmonary disease and from 24 clinically normal horses. Serum samples were collected from 35 of the horses with chronic obstructive pulmonary disease and from the 24 normal horses. Samples were tested for inhibition of hemagglutination by influenza A equine 1 and 2 viruses. There were high levels of hemagglutination inhibiting activity against influenza A equine 1 in mucus samples from horses with chronic obstructive pulmonary disease.  相似文献   
50.
OBJECTIVE: To assess agreement between arterial pressure waveform-derived cardiac output (PCO) and lithium dilution cardiac output (LiDCO) systems in measurements of various levels of cardiac output (CO) induced by changes in anesthetic depth and administration of inotropic drugs in dogs. ANIMALS: 6 healthy dogs. PROCEDURE: Dogs were anesthetized on 2 occasions separated by at least 5 days. Inotropic drug administration (dopamine or dobutamine) was randomly assigned in a crossover manner. Following initial calibration of PCO measurements with a LiDCO measurement, 4 randomly assigned treatments were administered to vary CO; subsequently, concurrent pairs of PCO and LiDCO measurements were obtained. Treatments included a light plane of anesthesia, deep plane of anesthesia, continuous infusion of an inotropic drug (rate adjusted to achieve a mean arterial pressure of 65 to 80 mm Hg), and continuous infusion of an inotropic drug (7 microg/kg/min). RESULTS: Significant differences in PCO and LiDCO measurements were found during deep planes of anesthesia and with dopamine infusions but not during the light plane of anesthesia or with dobutamine infusions. The PCO system provided higher CO measurements than the LiDCO system during deep planes of anesthesia but lower CO measurements during dopamine infusions. CONCLUSIONS AND CLINICAL RELEVANCE: The PCO system tracked changes in CO in a similar direction as the LiDCO system. The PCO system provided better agreement with LiDCO measurements over time when hemodynamic conditions were similar to those during initial calibration. Recalibration of the PCO system is recommended when hemodynamic conditions or pressure waveforms are altered appreciably.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号