首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   61篇
  免费   12篇
  国内免费   2篇
林业   1篇
  2篇
综合类   8篇
畜牧兽医   59篇
园艺   1篇
植物保护   4篇
  2020年   1篇
  2019年   1篇
  2018年   3篇
  2017年   3篇
  2016年   1篇
  2015年   5篇
  2014年   5篇
  2013年   5篇
  2012年   1篇
  2011年   9篇
  2010年   3篇
  2009年   7篇
  2008年   2篇
  2007年   2篇
  2006年   3篇
  2005年   2篇
  2004年   3篇
  2003年   2篇
  2001年   1篇
  2000年   1篇
  1998年   4篇
  1997年   2篇
  1996年   1篇
  1995年   1篇
  1992年   2篇
  1991年   1篇
  1990年   1篇
  1989年   3篇
排序方式: 共有75条查询结果,搜索用时 0 毫秒
71.
Objective To develop a method for identifying DNA of Aspergillus fumigatus from ostriches, using the polymerase chain reaction (PCR). A fumigatus is the principal causative agent of avian aspergillosis.
Design A biochemical trial.
Sample population Twelve Aspergillus fumigatus isolates and three other Aspergillus species.
Procedure PCR primers that were based on the sequence of the alkaline protease gene from human isolates of A fumigatus were used.
Results We successfully tested the method on ostrich isolates from five states and showed that the test is specific for A fumigatus.
Conclusions In most cases the DNA sequence of A fumigatus isolates from ostriches is similar to that of human isolates. DNA sequences vary significantly among A fumigatus isolates, including those from affected ostriches in the same flock. The genetic variation may be used to trace aspergillus infections in ostrich flocks and determine if the disease is transmitted by contact with infected birds.  相似文献   
72.
73.
Matrix metalloproteinases (MMPs) and their inhibitors (TIMPs) are involved in several reproductive events like oocyte–spermatozoa interaction and semen liquefaction. In order to study their role in the llama oviductal reproductive process, MMP activity in oviductal fluid (OF) was assayed. Considering that llama genome sequences are partially known, a strategy to procure cDNA sequences of MMP‐2, MMP‐9, TIMP‐1 and TIMP‐2 was designed. Afterwards, their expression patterns in the different llama oviductal segments were assayed. Gelatine zymograms detected 62 and 94 kDa protease activities that matched MMP‐2 and pro‐MMP‐9, respectively. Expression pattern analysis showed that MMP and TIMP mRNAs were present in ampulla, isthmus, utero‐tubal junction (UTJ) and papilla. Altogether, these findings support the argument that MMPs/TIMPs are produced in the oviduct and secreted into the oviductal lumen. Our results encourage further studies to elucidate the role of these proteins in reproductive oviductal events.  相似文献   
74.
Anesthetic respiratory effects of sevoflurane (SEVO) were compared with isoflurane (ISO) in unpremedicated dogs. Minimum alveolar concentration (MAC), apneic concentration (AC), and anesthetic index (AI) of SEVO and ISO were determined in eight 1‐year‐old healthy dogs, weighing 19 ± 3 kg (mean ± SEM) in a randomized complete block multiple cross‐over design. Dogs were mask‐induced with either SEVO or ISO in 100% oxygen. Following endotracheal intubation, dogs were instrumented, mechanically ventilated, and MAC was determined using a tail‐clamp method. Next, spontaneous ventilation was re‐established, and anesthetic concentration was increased to determine the AC. Throughout the anesthetic event, heart rate (HR), systolic blood pressure (SAP), mean blood pressure (MAP), diastolic blood pressure (DAP), respiratory rate (RR), end‐tidal carbon dioxide (Pe ′CO2), and oxyhemoglobin saturation (SpO2) were recorded at 3‐minute intervals. Following AC determination, AI was calculated as AC/MAC, and dogs were allowed to recover. Each dog was anesthetized four times (twice with ISO and SEVO each) at 1‐week intervals. All data were analyzed using the two‐way anova . Multiple comparisons were performed between ISO and SEVO treatments. Statistical significance was set at p < 0.05. Significant differences were noted between agents for MAC (SEVO, 2.13 ± 0.10%; ISO, 1.38 ± 0.14%; p < 0.0001), AC (SEVO, 7.34 ± 0.13%; ISO, 3.60 ± 0.13%; p < 0.0001), and AI (SEVO, 3.46 ± 0.22; ISO, 2.63 ± 0.14; p = 0.0002). Physiologic parameters were compared between SEVO and ISO at 1MAC, 2MAC, 3MAC, and AC. No differences were noted between SEVO and ISO treatments for cardiovascular parameters (HR, SAP, MAP, DAP). Significant differences were noted, favoring SEVO, for all respiratory parameters (RR, Pe ′CO2, SpO2) at increasing MAC multiples. Additionally, regression analysis was conducted for physiologic variable data points. Analysis of Pe ′CO2 data points demonstrated a significant slope difference of ?6.47 ± 1.02 (BSEVO ? BISO; p < 0.0001; r2 = 0.6042) favoring SEVO. While expected dose‐related ventilatory depression was noted for both agents, all the respiratory parameters for SEVO demonstrated less respiratory depression than ISO at equipotent doses. These results indicated that SEVO caused less dose‐dependent ventilatory depression than ISO, having a significantly higher AI and causing less detrimental change in pulmonary parameters at increasing levels of MAC.  相似文献   
75.
Objective To compare arterial blood pressure measurements obtained from the femoral and auricular arteries in anaesthetized pigs. Study design Prospective experimental study. Animals Fifteen female Large White pigs were used weighing 21.3 ± 2.3 kg. Methods The pigs were anaesthetized with tiletamine/zolazepam and xylazine administered intramuscularly, and anaesthesia maintained with isoflurane delivered in oxygen/nitrogen. Arterial oxygen partial pressures were maintained between 11.3 and 13.3 kPa and PaCO2 between 4.6 and 6.0 kPa. Monitoring included electrocardiogram, capnography and invasive blood pressure. The auricular and femoral arteries were catheterized for continuous systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) measurements. Measurements were recorded every 15 minutes. Statistical analysis involved a Bland–Altman plot analysis. Results The mean difference ± confidence intervals between the femoral and the auricular arterial diastolic, systolic and mean blood pressure measurements during hypotension were 2 ± 7, 2 ± 5 and 2 ± 5 mmHg respectively. In conditions of normotension mean difference ± confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 ± 5, 3 ± 7 and 4 ± 4 mmHg respectively. In conditions of increased arterial blood pressure, mean difference ± confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 ± 5, 3 ± 8 and 4 ± 4 mmHg respectively. Conclusion Auricular artery catheterization is easier and quicker to perform. Pressure measurements from the auricular artery compared well with the femoral artery. Clinical relevance We found that auricular arterial blood pressures were similar to femoral arterial values under the conditions of this experiment. We did not test extremes of blood pressure or significant alterations in body temperature.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号