Objective —To measure pullout strength of four pin types in avian humeri and tibiotarsi bones and to compare slow-speed power and hand insertion methods.
Study Design —Axial pin extraction was measured in vitro in avian bones.
Animal Population —Four cadaver red-tailed hawks and 12 live red-tailed hawks.
Methods —The pullout strength of four fixator pin designs was measured: smooth, negative profile threaded pins engaging one or two cortices and positive profile threaded pins. Part 1: Pins were placed in humeri and tibiotarsi after soft tissue removal. Part 2: Pins were placed in tibiotarsi in anesthetized hawks using slow-speed power or hand insertion.
Results —All threaded pins, regardless of pin design, had greater pullout strength than smooth pins in all parts of the study ( P < .0001). The cortices of tibiotarsi were thicker than the cortices of humeri ( P < .0001). There were few differences in pin pullout strengths between threaded pin types within or between bone groups. There were no differences between the pullout strength of pins placed by slow-speed power or by hand.
Conclusions —There is little advantage of one threaded pin type over another in avian humeri and tibiotarsi using currently available pin designs. There were few differences in pin pullout strengths between humeri and tibiotarsi bones. It is possible that the ease of hand insertion in thin cortices minimizes the potential for wobbling and therefore minimizes the difference between slow-speed drill and hand insertion methods.
Clinical Relevance —Threaded pins have superior bone holding strength in avian cortices and may be beneficial for use with external fixation devices in birds.  相似文献   
2.
3.
4.
Controlled cross circulation (CCC) was performed in six pairs of dogs for 45 minutes with aortic cross clamping and cardioplegia. Data were collected in donor dogs at 10 minute intervals three times before, three times during, and three times after CCC and included arterial blood pressure, pulmonary capillary wedge pressure (PCWP), central venous pressure (CVP), cardiac index (CI), heart rate (HR), blood gas analysis, temperature, maximum rate of rise of left ventricular pressure dP/dt max/End diastolic volume (EDV), blood volume (BV), complete blood count (CBC) and activated clotting times (ACT). Pulse pressure (PP), systemic vascular resistance (SVR), oxygen delivery (Do2), and left ventricular cardiac work (LVCW) were calculated. Arterial blood pressure, CVP, blood gas analysis, temperature, BV, CBC, and ACT were measured in recipient dogs. During CCC, donor hemodynamic changes resembled those observed in models of acute onset arteriovenous fistulas. Insidious BV shifts can occur despite the use of occlusive roller pumps. After CCC, donor hemodynamics resembled acute blood loss, characterized by decreases in mean arterial pressure (MAP), CVP, PCWP, and CI, and increases in SVR and dP/dt max/EDV. These changes were probably caused by pump imbalance and BV shift to the recipient dog.  相似文献   
5.
Jejunojejunal intussusception occurred after jejunal resection and stapled functional end-to-end anastomosis in two pony mares. In both mares, the lead point of the intussusception was the stapled functional end-to-end (FEE) anastomosis. The stapled free ends of jejunum were oversewn with an inverting suture pattern. A possible explanation for development of the intussusception was the acute angle created in the intestine by the FEE anastomsis. This angulation may have impaired flow of ingesta causing motility changes that predisposed the site to intussusception. Because the oversewn blind intestinal ends acted as the lead point for formation of the intussusception, it may be inadvisable to oversew the stapled anastomotic ends.  相似文献   
6.
7.
8.
OBJECTIVE: To evaluate the effect of knotting method on the mechanical properties of large diameter nonabsorbable monofilament suture materials. STUDY DESIGN: In vitro mechanical evaluation. METHODS: A conventional square knot was compared with the surgeon's knot, sliding half-hitch, and clamped square knot. Knotted suture loops were created in a uniform manner and acutely tensioned to failure (20 mm/min loading rate; n = 20 per knot type for each material). Stiffness, yield, and failure characteristics of USP #2 nylon, #2 polybutester, #2 polypropylene, 27 kg test monofilament nylon fishing line, and 27 kg nylon leader material were evaluated. RESULTS: Compared with a conventional square knot, a surgeon's knot decreased stiffness for #2 polypropylene, 27 kg fishing line, and 27 kg leader (P < .05). A sliding half-hitch weakened all materials except 27 kg leader (P < .05). Clamping the first throw of a square knot increased the stiffness of 27 kg leader loops (P < .05). CONCLUSIONS: Based on clinically relevant parameters (stiffness and yield), knotting method had no effect on #2 nylon and #2 polybutester. The surgeon's knot is not recommended for #2 polypropylene and 27 kg fishing line and leader material. A sliding half-hitch decreased the yield of leader material. Clamping the first throw of a square knot had no adverse effects on acute properties of tested materials; it increased the stiffness for leader material. CLINICAL RELEVANCE: Knotting method does influence the structural properties of suture materials and should be considered when tying knots under tension.  相似文献   
9.
10.
Objective— To compare the biomechanical characteristics, failure mode, and effects of side (left or right limb) and end (forelimb or hindlimb) of different screws in 2-screw, parallel-screw proximal interphalangeal joint arthrodesis constructs in horses.
Study Design— In vitro experimental study.
Sample Population— Twenty limbs from 6 cadavers (4 complete limb sets, 2 partial sets—total of 4 forelimb and 6 hindlimb pairs).
Methods— Two parallel 5.5 mm cortical (AO) screws were inserted in lag fashion in 1 randomly allocated limb of a pair, and 2 parallel headless, tapered, variable-pitched, titanium compression screws (Acutrak-Plus®) were inserted in the contralateral limb. Constructs were tested in 3-point bending in a dorsopalmar (plantar) direction using a materials-testing machine at a loading rate of 5.83 mm/s. Maximal bending moment at failure and composite stiffness were calculated from data generated on load–displacement curves. Data were analyzed using a Friedman 2-way analysis of variance and Wilcoxon's signed-rank tests.
Results— No significant difference was detected for bending moment or stiffness values in proximal interphalangeal joint arthrodesis constructs using 2 parallel Acutrak-Plus® or AO screws for fixation. Mean stiffness values were significantly different between forelimb and hindlimb constructs.
Conclusions— Performance of 2 parallel Acutrak-Plus® screws was biomechanically comparable with 2 parallel AO 5.5 mm cortical screws in in vitro pastern arthrodesis constructs.
Clinical Relevance— Acutrak-Plus® screws may provide an alternative means of fixation for proximal interphalangeal joint arthrodesis.  相似文献   