首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
畜牧兽医   4篇
  2021年   2篇
  2019年   1篇
  2017年   1篇
排序方式: 共有4条查询结果,搜索用时 687 毫秒
1
1.
ObjectiveTo compare values of haemoglobin concentration (SpHb), arterial haemoglobin saturation (SpO2) and calculated arterial oxygen content (SpOC), measured noninvasively with a pulse co-oximeter before and after in vivo adjustment (via calibration of the device using a measured haemoglobin concentration) with those measured invasively using a spectrophotometric-based blood gas analyser in anaesthetized dogs.Study designProspective observational clinical study.AnimalsA group of 39 adult dogs.MethodsIn all dogs after standard instrumentation, the dorsal metatarsal artery was catheterised for blood sampling, and a pulse co-oximeter probe was applied to the tongue for noninvasive measurements. Paired data for SpHb, SpO2 and SpOC from the pulse co-oximeter and haemoglobin arterial oxygen saturation (SaO2) and arterial oxygen content (CaO2) from the blood gas analyser were obtained before and after in vivo adjustment. Bland–Altman analysis for repeated measurements was used to evaluate the bias, precision and agreement between the pulse co-oximeter and the blood gas analyser. Data are presented as mean differences and 95% limits of agreement (LoA).ResultsA total of 39 data pairs were obtained before in vivo adjustment. The mean invasively measured haemoglobin–SpHb difference was –2.7 g dL?1 with LoA of –4.9 to –0.5 g dL?1. After in vivo adjustment, 104 data pairs were obtained. The mean invasively measured haemoglobin–SpHb difference was –0.2 g dL?1 with LoA of –1.1 to 0.6 g dL?1. The mean SaO2–SpO2 difference was 0.86% with LoA of –0.8% to 2.5% and that between CaO2–SpOC was 0.66 mL dL–1 with LoA of –2.59 to 3.91 mL dL–1.ConclusionsBefore in vivo adjustment, pulse co-oximeter derived values overestimated the spectrophotometric-based blood gas analyser haemoglobin and CaO2 values. After in vivo adjustment, the accuracy, precision and LoA markedly improved. Therefore, in vivo adjustment is recommended when using this device to monitor SpHb in anaesthetised dogs.  相似文献   
2.

Objective

To evaluate intraoperative and postoperative efficacy of ultrasound (US)-guided femoral (FN) and obturator (ON) nerves block, in the iliopsoas muscle compartment (IPM), using an in-plane technique.

Study design

Anatomical research and randomized, prospective, ‘blinded’ clinical study.

Animals

Six dog cadavers and 20 client-owned dogs undergoing tibial plateau levelling osteotomy (TPLO) surgery.

Methods

In phase 1, anatomical dissections and US imaging of the IPM were performed to design an US-guided nerve block involving the FN and ON simultaneously. The technique was considered successful if new methylene blue solution injection (0.1 mL kg?1) stained FN–ON for ≥2 cm. In phase 2, the US-guided nerve block designed in phase 1, combined with US-guided sciatic nerve (ScN) block, was performed in 20 dogs undergoing TPLO surgery. Patients were assigned randomly to one of two treatment groups: ropivacaine 0.3% (R3, n = 10) and ropivacaine 0.5% (R5, n = 10) at a volume of 0.1 mL kg?1 for each nerve block. Intraoperative success rate (fentanyl requirement < 2.1 mcg kg?1 hour?1) and postoperative pain score [Short Form-Glasgow Composite Measure Pain Scale (SF-GCMPS) ≥ 5/20] were evaluated.

Results

In phase 1, the US image of FN–ON was detected between L6 and L7. In-plane needling technique produced a staining of >4 cm in six of six cases. No abdominal or epidural dye spread was found. In phase 2, median fentanyl infusion rates were 0.5 (0.0–0.9) μg kg?1 hour?1 for R3 and 0.6 (0.0–2.2) μg kg?1 hour?1 for R5. At 9 and 11 hours after the peripheral nerve blocks, an SF-GCMPS ≥ 5 was observed for R3 and R5, respectively.

Conclusions and clinical relevance

The US-guided FN–ON block in the IPM, using an in-plane technique, combined with US-guided ScN block, provided sufficient analgesia to minimize the use of fentanyl during TPLO surgery. A longer postoperative analgesia was observed in group R5 compared with R3.  相似文献   
3.
A 4‐year‐old Border collie was presented with one episode of collapse, altered mentation, and a suspected pharyngeal stick injury. Magnetic resonance imaging (MRI) and computed tomography showed a linear foreign body penetrating the right oropharynx, through the foramen ovale and the brain parenchyma. The foreign body was surgically removed and medical treatment initiated. Complete resolution of clinical signs was noted at recheck 8 weeks later. Repeat MRI showed chronic secondary changes in the brain parenchyma. To the authors' knowledge, this is the first report of the advanced imaging findings and successful treatment of a penetrating oropharyngeal intracranial foreign body in a dog.  相似文献   
4.
ObjectiveTo evaluate two transducer and needle handling methods, along the visual axis (AL) and across the visual axis (AC), in non-skilled and skilled clinicians.Study designProspective randomized crossover study.MethodA total of 26 students with no ultrasound locoregional anaesthesia experience (non-skilled group) and six clinicians experienced and familiar with ultrasound locoregional anaesthesia (skilled group) were enrolled. The non-skilled group was asked to perform two tasks: the first on a phantom and the second on canine cadavers, whilst the skilled group performed only the second task. The tasks consisted of guiding the tip of the needle to a target point (simulated nerve on the jelly phantom and sciatic nerve on the cadavers) using two different methods of needle handling—AL or AC. All operators performed each task three times for each method. The time to drive the needle to the target for the two methods was analysed with a paired Student t test, and the number of times the needle was not visualized on the screen between the groups was compared using an unpaired Student t test. Data are presented as mean ± standard deviation. Value of p < 0.05 was considered significant.ResultsThe AL method, compared with the AC method, resulted in shorter performance time in both skilled (9 ± 5 versus 20 ± 8 seconds for the second task) and non-skilled groups (9 ± 8 versus 17 ± 15 seconds for the first task and 18 ± 11 versus 32 ± 26 seconds for the second task).Conclusion and clinical relevanceIn both groups, the AL method significantly reduced the time to complete the task. Results from this study indicate that the AL method should be the preferred method for learning/teaching ultrasound-guided regional anaesthesia.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号