首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   1篇
  1篇
畜牧兽医   20篇
  2021年   2篇
  2020年   1篇
  2019年   1篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2012年   1篇
  2011年   6篇
  2008年   1篇
  2005年   2篇
  2003年   1篇
  2002年   3篇
排序方式: 共有21条查询结果,搜索用时 46 毫秒
1.
A 7-year-old female Maltese presented for evaluation of severe vomiting. A diagnosis of pylorogastric intussusception was made during ultrasonographic examination. The intussusception spontaneously underwent reduction by the following morning.  相似文献   
2.
Some studies have shown that relative to baseline, the renal resistive index (RI) remains unchanged in nonobstructed kidneys and increases in obstructed kidneys after administration of furosemide. To our knowledge, the effect of mannitol administration on the renal RI of dogs has not been reported. We evaluated the renal RI in 16 kidneys in 8 young adult dogs after administration of mannitol. The mean RI decreased significantly from baseline (P < .01). Additionally, left complete ureteral obstruction wasinduced in 5 dogs. Evaluation by Doppler ultrasonography was performed for 5 days. On the 5th day, Doppler examination was repeated at 30 and 60 minutes after administration of mannitol to obstructed dogs. After induction of left ureteral obstruction, the RI of the left kidney increased significantly over 5 consecutive days. Administration of mannitol decreased the RI in the nonobstructed contralateral kidneys, and thus the RI difference between obstructed and nonobstructed kidneys was increased above normal (P < .001). In conclusion, administration of mannitol may be useful as another diuretic agent to identify unilateral ureteral obstruction on Doppler sonographic examination.  相似文献   
3.
Color Doppler imaging (CDI) was carried out to evaluate the effects of anti-glaucoma drugs on ophthalmic circulation using CDI-derived resistive index (RI) values. CDI was performed on nine Beagle dogs, and RI values were calculated for the medial long posterior ciliary artery before and after the administration of anti-glaucoma drugs. A significant increase in RI values was found after topical administration of levobunolol (p < 0.05) or dipivefrin (p < 0.05). Pilocarpine showed no effects on RI values after topical administration. The results suggest that some anti-glaucoma drugs could affect ophthalmic blood flow.  相似文献   
4.
The objective of this study was to determine relationship of gestational age with measurement of diameter of head, orbit, trunk, long and short axis of heart, aorta, placentome, umbilical cord and umbilical vein in Korean black goats. In this study, ten pregnant Korean black goats (Capra hircus aegagrus) were used. Pregnancy diagnosis was performed with a 5 MHz linear transducer and ultrasonographic scan were performed at 60, 75, 90, 105, 120 and 135 days after mating with a 4-9 MHz convex transducer. For accurate measurement, all fetal organs were measured at least 3 times. The diameter of head, orbit, trunk, long and short axis of heart, aorta, placentome, umbilical cord and umbilical vein were significantly increased with the gestational age (p<0.05). Of these parameters, trunk (r=0.8876; p<0.001), long axis of heart (r=0.9168; p<0.001) and short axis of heart (r=0.8819; p<0.001) proved to be the more effective measurements than other parameters, as it correlated well with gestational age. Results indicate that ultrasonic measurements of these parameters were useful methods to estimate gestational age in Korean black goat.  相似文献   
5.
6.
7.
Dongwoo  Chang  DVM  MS  Bongkyeong  Kim  DVM  MS  Youngmin  Yun  DVM  PHD  Yongmin  Hur  MD  Youngwon  Lee  DVM  PHD  Mincheol  Choi  DVM  PHD  Junghee  Yoon  DVM  PHD  Jekyung  Seong  DVM  PHD 《Veterinary radiology & ultrasound》2002,43(1):37-42
The role of superparamagnetic iron oxide as a tissue-specific contrast medium has been established in humans, especially for hepatic imaging. Superparamagnetic iron oxide particles exhibit a tissue-specific biodistribution to the reticuloendothelial system, where they predominantly shorten transverse T2 relaxation time. Most hepatic tumors lack Kupffer cells; therefore, the T2 of tumors remains virtually unchanged after administration of superparamagnetic iron oxide. The resulting loss of signal intensity from the liver, with unchanged tumor signal intensity, increases lesion-to-liver contrast. In this study, MR images were acquired with fast gradient echo recalled at steady state (FGRE) in five Beagle dogs before and after injection of superparamagnetic iron oxide. The effect of superparamagnetic iron oxide on signal intensity of the liver with time was assessed. A signal intensity decrease of 65.7+/-10.0% was detected at 20 minutes, and it continued to decrease until the last time point of MR scanning (200 minutes). The liver intensity of all dogs dropped to half its value after 20 minutes. The effect of motion was minimized by breath holding. Superparamagnetic iron oxide did not have any adverse effects on the dogs.  相似文献   
8.
Pharyngeal collapsibility has been used as diagnostic criteria in dogs, whereas the normal range and quantitative method have not been studied. Dynamic and static computed tomography (CT) was performed in 23 normal Beagle dogs to quantify the nasopharyngeal collapsibility at different locations. Using dynamic CT, maximum and minimum nasopharyngeal cross-sectional areas (CSAs) were measured at the level of the cranial end of the soft palate, pterygoid hamulus, foramen lacerum, bony labyrinth, and caudal end of the soft palate. The ratio of all maximum and minimum CSA to nasopharyngeal CSA at the level of the caudal hard palate (rCSAmax and rCSAmin) and the nasopharyngeal collapsibility were calculated. The differences of rCSAmax, rCSAmin, and nasopharyngeal collapsibility were analyzed at various locations. The nasopharyngeal collapsibility at the level of foramen lacerum, bony labyrinth, and caudal end of soft palate were higher than the others. At the level of the caudal end of the soft palate, rCSAmin was lower than that of the foramen lacerum and bony labyrinth, whereas rCSAmax at foramen lacerum was higher than that of the caudal end of the soft palate. These results indicated that the nasopharynx at the level of foramen lacerum and caudal end of the soft palate were considered notable locations for evaluating collapsibility. Dynamic CT could show the nasopharyngeal dynamic profile and will be an adequate modality for evaluating nasopharynx. Our results will be helpful for further comparative studies in dogs with and without nasopharyngeal collapse.  相似文献   
9.
10.
This study aimed to determine the optimal placement of the region of interest (ROI) among four anatomical sites—pulmonary artery (PA), pulmonary vein (PV), aortic arch (AA), and carotid artery (CA)—in computed tomography (CT) brain angiography with automatic bolus tracking in healthy beagle dogs. Six beagles were included, and CT brain angiography was performed four times for each dog, to cover each ROI. The scan parameters, amount, and injection rate of the contrast medium were the same. The major intracranial arteries were selected for quantitative and qualitative evaluation: caudal cerebellar artery (CcA), basilar artery (BA), rostral cerebellar artery (RcA), caudal cerebral artery (CCA), middle cerebral artery (MCA), and rostral cerebral artery (RCA). Quantitative evaluation showed significantly higher CT attenuation values for the RcA, CCA, and MCA in the PA group and RcA and MCA in the PV group than in the CA group. Qualitative analysis revealed significantly higher scores for the BA, CCA, and MCA in the PA and PV groups than in the CA group. Venous contamination did not differ significantly among the ROIs, but the mean scores of the AA and CA groups were higher than those of the PA and PV groups. CT brain angiography using bolus tracking in the beagle dogs showed that the ROI should be placed at the PA or PV rather than at the CA for optimal images with strong contrast enhancement of the BA, RcA, CCA, and MCA and minimal venous contamination.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号