Colorimetric assay for the quantification of serum iodixanol concentration and its application on estimation of glomerular filtration rate in cattle
Authors:Miura Moe  Yamagishi Norio  Sasaki Kouya  Kim Danil  Devkota Bhuminand  Furuhama Kazuhisa
Institution:Department of Veterinary Clinical Medicine, Iwate University, Morioka 020-8550, Japan.
Abstract:A colorimetric assay used to quantify the non-ionic contrast medium iodixanol in sera was validated and compared with high-performance liquid chromatography. The application of this assay to estimate glomerular filtration rates (GFR) in cattle was examined. Serum iodixanol was de-iodinated by alkaline hydrolysis and the amount of released iodine was subsequently determined using a ceric arsenite method. There was a close correlation between the two methods using identical specimens. In clinically healthy cattle with different body weights, the reference value (166.3-178.8 mL/min/m(2)) based on body surface area was fairly stable as compared with that (2.13-3.63 mL/min/kg) based on body weight. Based on GFR data in healthy and renal-impaired cattle, when the GFR decreased to more than 60% of the reference value, serum urea nitrogen and creatinine concentrations increased. The colorimetric assay is a simple method for the estimation of GFR in cattle and requires no expensive equipment.