Abstract: | A rapid normal‐phase high‐performance liquid chromatography (NP‐HPLC) method has been developed for rapid determination of the total content of tocopherols (T) and tocotrienols (T3) in cereals. The new method uses a one‐step extraction followed by NP‐HPLC coupled with a fluorescence detector. The new method provides a baseline separation of the critical peaks of beta‐tocotrienol (β‐T3) and gamma‐tocopherol (γ‐T) within a short time of analysis. The extraction step requires no saponification step or addition of antioxidant. Addition of butylated hydroxytoluene (BHT) had no effect on the stability of vitamin E during sampling. The recovery was 96–100%. The method is demonstrated by successful quantification of vitamin E in barley, wheat, and spelt grains, as well as wheat germ and flours from wheat, spelt, and rye. |