首页 | 本学科首页   官方微博 | 高级检索  
     检索      

辐照孜然的ESR法鉴定及原初吸收剂量的估算
引用本文:李伟明,哈益明,王锋,张彦立.辐照孜然的ESR法鉴定及原初吸收剂量的估算[J].中国农业科学,2011,44(8):1688-1693.
作者姓名:李伟明  哈益明  王锋  张彦立
作者单位:1. 中国农业科学院农产品加工研究所; 2. 中国农业科学院农产品加工研究所;农业部辐照产品质量监督检验测试中心; 3. 中国计量科学研究院;
基金项目:农业部公益性行业科技专项,国防科工局核能开发科研专项,农业行业标准制定和修订(184号)项目
摘    要: 【目的】检测孜然是否经过辐照处理并估算孜然原初吸收剂量;【方法】以孜然为对象,采用电子自旋共振波谱(ESR)技术研究孜然在0~15.0 kGy剂量范围内ESR波谱特征变化,分析辐照剂量与信号强度的关系以及贮藏时间对自由基浓度的影响,并采用附加剂量法估测孜然样品的原初吸收剂量;【结果】辐照后孜然的ESR波谱信号强度随辐照剂量增加而增大,经过220 d贮藏期后仍能应用ESR波谱法检测孜然是否经过辐照处理。附加剂量法能够用于辐照孜然的剂量估算,其中利用3次多项式在不同贮藏时间里(10 d,20 d和30 d)拟合估算出的每个样品的剂量值与原初剂量的偏差均在1 kGy范围内,比用对数方程拟合估算出的剂量值更为准确;【结论】ESR波谱技术能够定性和定量鉴定辐照孜然。

关 键 词:辐照  电子自旋共振  贮藏  附加剂量法  信号强度
收稿时间:2010-10-12;

Identification and Estimation of the Initial Absorbed Dose in Irradiated Cumin by ESR Spectrometry
LI Wei-ming,HA Yi-ming,WANG Feng,ZHANG Yan-li.Identification and Estimation of the Initial Absorbed Dose in Irradiated Cumin by ESR Spectrometry[J].Scientia Agricultura Sinica,2011,44(8):1688-1693.
Authors:LI Wei-ming  HA Yi-ming  WANG Feng  ZHANG Yan-li
Institution:LI Wei-ming1,HA Yi-ming1,WANG Feng1,ZHANG Yan-li2(1 Institute of Agro-Food Science & Technology,Chinese Academy of Agricultural Sciences/ Key Opening Laboratory of Agricultural Products Processing and Quality Control,Ministry of Agriculture,Beijing 100193,2National Institute of Metrology P.R.China,Beijing 100013)
Abstract:【OBJECTIVE】The objective of this study is to detect whether or not the cumin has been irradiated and estimate the initial absorbed dose of cumin;【METHOD】The cumin was studied as experimental material to investigate the feature changes of ESR spectrum and the relationship between ESR intensity and irradiation dose in the range of 0 to 15.0 kGy and the initial absorbed dose of cumin was assessed by using the dose-additive method;【RESULTS】The ESR signal intensity of irradiated cumin increased with the increasing of the absorbed dose and even after 220 days ESR method could also be used to identify whether or not the cumin has been irradiated. The dose additive method can be used for a reliable evaluation of the absorbed dose in cumin and the deviation between the initial dose and the dose estimated by using 3rd degree polynomial function at different storage times (10, 20 and 30 days) after initial irradiation is all less than 1 kGy, the estimated doses of samples using the 3rd polynomial function are more close to the actual doses than using the exponential function.;【CONCLUSION】The ESR technique could be used as a qualitative and quantitative method to indentify irradiated cumin.
Keywords:spices  cumin  irradiation  electron spin resonance  storage  dose-additive method  signal intensity  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国农业科学》浏览原始摘要信息
点击此处可从《中国农业科学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号