鸡传染性支气管炎病毒抗体间接ELISA检测方法的建立
引用本文:郑卫峰,闫芳,王盼,赵宇军,高文伟,马海利,李绪英,宁官保,田文霞,梁慧霞,刘林.鸡传染性支气管炎病毒抗体间接ELISA检测方法的建立[J].中国畜牧兽医,2015,42(6):1383-1388.
作者姓名:郑卫峰  闫芳  王盼  赵宇军  高文伟  马海利  李绪英  宁官保  田文霞  梁慧霞  刘林
作者单位:山西农业大学动物科技学院, 兽医微生物与免疫学实验室, 太谷 030801
基金项目:山西省科技攻关项目(20120311023-5)
摘    要:为建立快速检测鸡传染性支气管炎病毒(IBV)的血清学方法,本试验以IBV为检测抗原,建立了一种检测IBV抗体的间接ELISA方法,并对各种检测条件进行了优化.研究结果显示,抗原的最佳包被浓度为19.2 μg/mL,最佳包被条件为37 ℃ 1 h后4 ℃过夜;血清的最佳稀释度为1:800,37 ℃孵育60 min;酶标二抗稀释度为1:7 000,37 ℃孵育60 min;底物显色为37 ℃避光作用10 min.经特异性、重复性、敏感性试验证明,该方法与鸡常见病原的阳性血清均无交叉反应,重复性较好及血清稀释至1:12 800时仍可检测到IBV抗体.结果表明,本试验所建立的间接ELISA方法具有良好的特异性、重复性和敏感性.

关 键 词:鸡传染性支气管炎病毒(IBV)  间接ELISA  抗体检测  
收稿时间:2014-11-10

Establishment of Indirect ELISA Method for Detecting Antibodies against Avain Infectious Bronchitis Virus
ZHENG Wei-feng,YAN Fang,WANG Pan,ZHAO Yu-jun,GAO Wen-wei,MA Hai-li,LI Xu-ying,NING Guan-bao,TIAN Wen-xia,LIANG Hui-xia,LIU Lin.Establishment of Indirect ELISA Method for Detecting Antibodies against Avain Infectious Bronchitis Virus[J].China Animal Husbandry & Veterinary Medicine,2015,42(6):1383-1388.
Authors:ZHENG Wei-feng  YAN Fang  WANG Pan  ZHAO Yu-jun  GAO Wen-wei  MA Hai-li  LI Xu-ying  NING Guan-bao  TIAN Wen-xia  LIANG Hui-xia  LIU Lin
Institution:Veterinary Microbiology and Immunology Laboratory, College of Animal Science and Veterinary Medicine, Shanxi Agricultural University, Taigu 030801, China
Abstract:The purpose of this research was to establish a rapid detection serological method against avain infectious bronchitis virus (IBV).In this study,an indirect ELISA method was established using IBV as the detected antigen and a variety of testing conditions were optimized.The results showed that the optimal antigen coating concentration was 19.2 μg/mL and the optimal condition for coating was incubated at 37 ℃ for 1 h and then 4 ℃ overnight.The optimal dilutions of serum and enzyme labeled antibody were 1:800 and 1:7 000 incubated at 37 ℃ for 60 min,respectively.The optimal condition of chromogenic substrate was incubated at 37 ℃ for 10 min in the dark.The specificity,repeatability and sensitivity tests proved that the indirect ELISA did not cross-react with positive antiviral sera of other chicken diseases,had good repeatability and could detect IBV antibody when serum was diluted 1:12 800.We concluded that the established indirect ELISA was specific,repeatable and sensitive.