首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Application of Serial Ports Simulation in a Non-communication Fault Detection Device of Distribution Networks
作者姓名:LIU Zi-y  LIU He-ping  ZHOU Nian-chen  LIU Zhao
作者单位:1. Management Department of the Airport, Chongqing Airport Group Ltd, Chongqing 401120, China; 2. College of Electrical Engineering, Chongqing University, Chongqing 400030, China
摘    要:This paper summarizes two kinds of fault detection techniques for distribution automation, that is with and without communication in fault detection, and then analyzes their merits and shortcomings. Moreover, according to the development tendency of distribution automation techniques, this paper presents an approach, through which the noncommunication FTU devices can detect transient fault voltage of distribution systems effectually. To detect transient fault voltage without standby batteries, the PIC Single Chip microcomputer with low power consumption and DSP chip with powerful data processing capabilities are adopted to form a dual CPU system. To realize the communication between the two CPUs, the general I/O port,s of the DSP chip are firstly used to simulate the UART communication of the serial ports and communicate with the PIC Single Chip microcomputer. The novel FTU devices based on this approach are tested in static and dynamic simulation experiments, the results are satisfied.

关 键 词:distribution  automation    transient  fault  voltage  detection      UART  Simulation
收稿时间:2006/2/13 0:00:00
修稿时间:2006/2/13 0:00:00

Application of Serial Ports Simulation in a Non-communication Fault Detection Device of Distribution Networks
LIU Zi-y,LIU He-ping,ZHOU Nian-chen,LIU Zhao.Application of Serial Ports Simulation in a Non-communication Fault Detection Device of Distribution Networks[J].Storage & Process,2006(6):58-62.
Authors:LIU Zi-y  LIU He-ping  ZHOU Nian-chen  LIU Zhao
Institution:1. Management Department of the Airport, Chongqing Airport Group Ltd, Chongqing 401120, China; 2. College of Electrical Engineering, Chongqing University, Chongqing 400030, China
Abstract:This paper summarizes two kinds of fault detection techniques for distribution automation, that is with and without communication in fault detection, and then analyzes their merits and shortcomings. Moreover, according to the development tendency of distribution automation techniques, this paper presents an approach, through which the noncommunication FTU devices can detect transient fault voltage of distribution systems effectually. To detect transient fault voltage without standby batteries, the PIC Single Chip microcomputer with low power consumption and DSP chip with powerful data processing capabilities are adopted to form a dual CPU system. To realize the communication between the two CPUs, the general I/O port,s of the DSP chip are firstly used to simulate the UART communication of the serial ports and communicate with the PIC Single Chip microcomputer. The novel FTU devices based on this approach are tested in static and dynamic simulation experiments, the results are satisfied.
Keywords:distribution automation  transient fault voltage detection  UART Simulation
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏