AN EVALUATION OF A NEW RADIOGRAPHIC TECHNIQUE UTILIZING A CONCAVE TABLE
Authors:Yoshihiro  Kishigami  DVM  Arata  Yoshizaki  DVM  Daisuke  Saito  DVM  Hirokazu  Seo  DVM
Institution:Kishigami Veterinary Hospital, 1-6-1 Maruyama Drive, Abeno, Osaka 545–0042, Japan.
Abstract:In conventional radiography systems, it is apparent that only the area immediately around the central x-ray beam can be evaluated accurately. Consequently in some instances, spinal radiography for example, several exposures are needed at various points along the body to create an accurate image for diagnosis. However, if the film and body part are in a concave shape such that the radius of the curve is equal to the film focal distance, the x-ray beam will penetrate the body and strike the film at two-dimensionally right angles in all areas. Using the spine as an example we found the curved technique had three major advantages over the traditional flat technique: lack of distortion, more uniform beam intensity due to a constant focal film distance, and improved resolution at the periphery of the radiograph because of lack of a cross over effect. It was concluded that an accurate evaluation of larger body parts can be made with minimal distortion utilizing the principles of a curved table technique.
Keywords:radiology  technique  curved table  spine  intervertebral disc space  dog