首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Liquid chromatographic determination of ochratoxin A in coffee beans and coffee products
Authors:H Terada  H Tsubouchi  K Yamamoto  K Hisada  Y Sakabe
Abstract:A liquid chromatographic method for the determination of ochratoxin A in coffee beans (green and roast), instant coffee, and coffee drink is described. The sample is subjected to extraction with methanol-1% aqueous sodium bicarbonate (1 + 1) and C18 cartridge cleanup. The extract is chromatographed on a Nucleosil 5C18 column with a mobile solvent of acetonitrile-water-0.2M phosphate buffer pH 7.5 (50 + 47 + 3) containing 3 mM cetyltrimethylammonium bromide as an ion-pair reagent. Ochratoxin A is detected with a fluorometer (excitation 365 nm, emission 450 nm). The sensitivity was increased 20-fold by using ion-pair resolution. The detection limits corresponded to 2 micrograms/kg for coffee beans, 5 micrograms/kg for instant coffee, and 0.2 microgram/kg for coffee drink. The recoveries from coffee products were generally better than 80.7% and the relative standard deviations were 3.43-5.93%. The peak coinciding with ochratoxin A can be confirmed by treatment using alcohol (methanol, ethanol, or n-propanol) and H2SO4.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号