首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高效液相色谱法同时测定液态乳中的2种紫外吸收剂和2种抗氧化剂
引用本文:张大原,李挥,张兰天,艾连峰.高效液相色谱法同时测定液态乳中的2种紫外吸收剂和2种抗氧化剂[J].乳业科学与技术,2016,39(2):17-20.
作者姓名:张大原  李挥  张兰天  艾连峰
作者单位:河北省食品检验研究院,河北省食品安全重点实验室,河北石家庄 050091;河北衡水中学,河北衡水 053000;河北省食品检验研究院,河北省食品安全重点实验室,河北石家庄 050091;河北出入境检验检疫局,检验检疫技术中心,河北石家庄 050051
基金项目:河北省科技计划项目(15275505D)
摘    要:建立液态乳中2种紫外吸收剂(UV-326和UV-1577)和2种抗氧化剂(AO-1010、AO-2246)的高效液相色谱测定方法.前处理采用乙腈提取液态乳中目标化合物,样品用正己烷提取;检测经Agilent HC-C8反相色谱柱,以乙腈-水作为流动相,梯度洗脱程序进行分离,280 nm波长下检测.结果表明:分析物在0.05~50 μg/mL质量浓度范围内线性关系良好,线性相关系数>0.999 5,方法检出限为0.02~0.5 mg/kg.方法在3个水平的加标回收率为69.08%~115.87%,相对标准偏差为0.43%~9.94%.该方法操作简单、灵敏度高、重现性好,适用于液态乳中紫外吸收剂和抗氧化剂的同时测定.

关 键 词:高效液相色谱  紫外吸收剂  抗氧化剂  液态乳  

Simultaneous Determination of 2 Ultraviolet Absorbers and 2 Antioxidants in Milk by High Performance Liquid Chromatography
ZHANG Dayuan,LI Hui,ZHANG Lantian,AI Lianfeng.Simultaneous Determination of 2 Ultraviolet Absorbers and 2 Antioxidants in Milk by High Performance Liquid Chromatography[J].JOURNAL OF DAIRY SCIENCE AND TECHNOLOGY,2016,39(2):17-20.
Authors:ZHANG Dayuan  LI Hui  ZHANG Lantian  AI Lianfeng
Institution:(1.Hebei Key Laboratory of Food Safety, Hebei Food Inspection and Research Institute, Shijiazhuang 050091, China; 2.Hebei Hengshui High School, Hengshui 053000, China; 3.Hebei Entry-Exit Inspection and Quarantine Technical Center, Hebei Entry-Exit Inspection and Quarantine Bureau, Shijiazhuang 050051, China)
Abstract:A method was developed for the simultaneous determination of 2 ultraviolet absorbers UV-326, UV-1577 and 2 antioxidants AO-1010 and AO-2246 in milk by high performance liquid chromatography. Samples were extracted with acetonitrile. The effective separation of the target analytes was accomplished on Agilent HC-C8 (150 mm × 4.6 mm, 5.0 μm) column with gradient elution procedure using a mixture of water and acetonitrile as the mobile phase. External calibration was used for quantitative determination at detection wavelength of 280 nm. The linearity of 4 analytes were satisfactory with a correlation coefficient of > 0.9995 at concentrations ranging from 0.05 to 50 μg/mL. The limits of detection of the method were 0.02?0.5 mg/kg, and the recoveries at different spiked levels and precision (RSD) were 69.08%?115.87% and 0.43%?9.94%, respectively. The method is simple, sensitive, reproducible and suitable for the simultaneous determination of 2 ultraviolet absorbers and 2 antioxidants in milk.
Keywords:high performance liquid chromatography (HPLC)  ultraviolet absorber  antioxidants  milk  
本文献已被 CNKI 等数据库收录!
点击此处可从《乳业科学与技术》浏览原始摘要信息
点击此处可从《乳业科学与技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号