Effects of ventilation and air temperature on pollution levels in underground car parks |
| |
Authors: | M I Yaziz A W P Yen |
| |
Institution: | 1. Department of Environmental Sciences, Universiti Pertanian Malaysia, 43400, Serdang, Selangor, Malaysia
|
| |
Abstract: | The relationship between the levels of CO and airborne Pb was evaluated against conditions of traffic flow, ambient air temperature and the ventilation rates in 3 underground car parks. During the study period significant variations were noted in the levels of the pollutants in each of the car parks which frequently exceeded the proposed Malaysian Air Quality Standard of 0.7 μg m?3Pb and 9 μg L?1 (8 hr average) CO for indoor environs. High correlation coefficient values were obtained between the levels of CO and traffic flow and Pb and traffic flow. High traffic flow also increased the mean air temperature inside the car parks. Reductions in the ventilation rates in the car parks caused an almost two-fold increase in the level of CO and vice versa. A simple mathematical model depicting the CO concentrations in relation to other parameters was formulated. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|