首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Cardiac‐gated,phase contrast magnetic resonance angiography is a reliable and reproducible technique for quantifying blood flow in canine major cranial abdominal vessels
Authors:Francesca Del Chicca  Andrea Schwarz  Paula Grest  Florian Willmitzer  Matthias Dennler  Patrick R Kircher
Institution:1. Clinic of Diagnostic Imaging, Vetsuisse Faculty University of Zurich, Zurich, Switzerland;2. Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland;3. Section of Anaesthesiology, Equine Department, Vetsuisse Faculty University of Zurich, Zurich, Switzerland;4. Institute of Veterinary Pathology, Vetsuisse Faculty University of Zurich, Zurich, Switzerland
Abstract:Blood flow changes in cranial abdominal vessels are important contributing factors for canine hepatic disease. This prospective, experimental, pilot study aimed to evaluate cardiac‐gated, phase contrast magnetic resonance angiography (PCMRA) as a method for characterizing blood flow in canine major cranial abdominal vessels. Eleven, healthy, adult beagle dogs were sampled. Cardiac‐gated, phase contrast magnetic resonance angiography of the cranial abdomen was performed in each dog and blood flow was independently measured in each of the major cranial abdominal vessels by three observers, with two observers recording blood flow values once and one observer recording blood flow values three times. Each dog then underwent ultrasonographic examination of the liver with fine needle aspirations and biopsies submitted to cytologic and histologic examination. The mean absolute stroke volume and velocity were respectively 9.6 ± 1.9 ml and –11.1 ± 1.1 cm/s for the cranial abdominal aorta, 2.1 ± 0.6 ml and –6.6 ± 1.9 cm/s for the celiac artery, and 2.3 ± 1.0 ml and –7.9 ± 3.1 cm/s for the cranial mesenteric artery. The mean absolute stroke volume and velocity were respectively 6.7 ± 1.3 ml and 3.9 ± 0.9 cm/s for the caudal vena cava and 2.6 ± 0.9 ml and 3.2 ± 1.2 cm/s for the portal vein. Intraobserver reliability was excellent (intraclass correlation coefficient > 0.9). Interobserver reproducibility was also excellent (intraclass correlation coefficient 0.89–0.99). Results of liver ultrasonography, cytology, and histopathology were unremarkable. Findings indicated that cardiac‐gated, phase contrast magnetic resonance angiography is a feasible technique for quantifying blood blow in canine major cranial abdominal vessels. Blood flow values from this sample of healthy beagles can be used as background for future studies on canine hepatic disease.
Keywords:blood flow  healthy dogs  magnetic resonance  noninvasive
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号