首页 | 本学科首页   官方微博 | 高级检索  
     检索      

轴流泵马鞍区水力性能与压力脉动测试与分析
引用本文:何乃昌,谈明高,刘厚林,黄鑫,吴贤芳.轴流泵马鞍区水力性能与压力脉动测试与分析[J].排灌机械工程学报,2018,36(2):118-123.
作者姓名:何乃昌  谈明高  刘厚林  黄鑫  吴贤芳
作者单位:1.江苏大学国家水泵及系统工程技术研究中心, 江苏 镇江 212013; 2.苏尔寿污水处理设备(上海)有限公司, 上海 200122; 3.江苏大学能源与动力工程学院, 江苏 镇江 212013
摘    要:为了分析轴流泵在马鞍区工况的运行特性,对一轴流泵不同工况下的外特性和压力脉动进行了测试,重点分析了轴流泵马鞍区水力特性和压力脉动特性.试验结果表明:模型泵H-Q曲线在0.50Qd~0.60Qd内表现出明显的马鞍形,且扬程在马鞍区内0.55Qd工况时达到最小值,较0.60Qd工况扬程降低0.33 m,为设计工况下扬程的5.5%;叶轮进口和泵出口处压力脉动具有较为明显的周期性,单个周期内压力脉动表现出明显的4波峰4波谷特征;0.55Qd工况时,叶轮进口处压力脉动峰峰值为设计工况的2.3倍;各工况下导叶中间和出口处压力脉动规律较为复杂;叶轮进口压力脉动主频为叶片通过频率,0.55Qd工况叶频处的幅值最大,高于设计工况27.6%.小流量工况下,导叶中间、导叶出口处压力脉动在频域内出现较多低频信号,压力脉动频率成分较复杂.泵出口压力脉动主频在1.00Qd工况下明显表现为叶频.研究成果可为轴流泵不稳定运行特性的优化提供参考.

关 键 词:轴流泵  马鞍区  水力特性  压力脉动  
收稿时间:2016-05-06

Test and analysis on pressure pulsation and hydraulic performance of saddle zone in axial flow pump
HE Naichang,TAN Minggao,LIU Houlin,HUANG Xin,WU Xianfang.Test and analysis on pressure pulsation and hydraulic performance of saddle zone in axial flow pump[J].Journal of Drainage and Irrigation Machinery Engineering,2018,36(2):118-123.
Authors:HE Naichang  TAN Minggao  LIU Houlin  HUANG Xin  WU Xianfang
Institution:1.National Research Center of Pumps, Jiangsu University, Zhenjiang, Jiangsu 212013, China; 2.Sulzer Sewage Treatment Equipment(Shanghai)Co. Ltd., Shanghai, 200122, China; 3.School of Energy & Power Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
Abstract:In order to analyze the running characteristics of axial flow pump in saddle zone, the pressure pulsation and hydraulic performance of saddle zone in an axial flow pump were tested under diffe-rent conditions. The pressure pulsation and hydraulic performance of saddle zone in the axial flow pump were analyzed. The results show that the H-Q curve of the model pump has an obvious saddle zone under small flow rate conditions in the axial flow pump. Saddle zone is in the flow rate range of 0.50Qd-0.60Qd. There is a minimum head at 0.55Qd which is lower than the head at 0.60Qd by 0.33 m. And the difference is 5.5% of design head. The pressure pulsation at the impeller inlet and pump outlet has an obvious time domain periodicity which reflects the four wave crest and trough behavior in one period. The peak-to-peak value of pressure pulsation at the impeller inlet at 0.55Qd is 2.3 times the value under design condition. The pressure pulsation regularity of guide vane middle and outlet is complex. The main frequency at the impeller inlet is the blade passing frequency. The maximum pressure pulsation amplitude is located at the blade passing frequency of 0.55Qd,which is 27.6% higher than the maximum amplitude of the pressure pulsation at design condition. There appear many low-frequency signals at guide vanes middle and outlet under small flow rate conditions and the pressure pulsation is complicated. The main frequency at the pump outlet shows a blade passing frequency at design condition. The research results can provide a reference for the optimization of unstable running characteristics in the axial flow pump.
Keywords:axial flow pump  saddle zone  hydraulic performance  pressure pulsation  
本文献已被 CNKI 等数据库收录!
点击此处可从《排灌机械工程学报》浏览原始摘要信息
点击此处可从《排灌机械工程学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号