摘    要:输油气站内生活采暖和制冷设备大多是电暖器和空气源热泵,能耗较高.从节能角度出发,分析了地源热泵技术的工作原理、工作过程及其相对于空气源热泵的优势.以北京某输气站为例,根据站内地质、气候特征,按照埋地换热器、负荷、流量设计计算方法,确定设备型号、传热介质类型及地埋管布局,在输气站内设计建造地源热泵系统.按照有关标准,对该系统进行节能监测,并分析其节能效果,结果表明:与空气源热泵相比,该系统节能率为27.62%;与电暖器相比,节能率可达63.81%,节能效果明显,长期运行经济效益可观,具有推广应用价值.

关 键 词:输气站场  地源热泵  埋地换热器  节能监测

Application and energy-saving analysis of ground source heat pump system in gas transmission station
Zhang Xin,Zhang Xudong,Gu Yingcui,Li Rui,Liu Guohao,Hou Yu,Xu Tie,Zhao Guoxing.Application and energy-saving analysis of ground source heat pump system in gas transmission station[J].Oil & Gas Storage and Transportation,2012,31(9):703-706,6.
Authors:Zhang Xin  Zhang Xudong  Gu Yingcui  Li Rui  Liu Guohao  Hou Yu  Xu Tie  Zhao Guoxing
Institution:1.National Engineering Laboratory of Transportation Safety of Oil & Gas Pipeline,PetroChina Pipeline R&D Center 2.PetroChina Beijing Natural Gas Pipeline Company Limited
Abstract:Livelihood heating and cooling equipments in the oil and gas transmission station are mostly electric heaters and air source heat pumps with higher energy consumption.From the perspective of energy saving,working principle and process of the ground source heat pump(GSHP) and its advantages relative to the air source heat pump are analyzed.Take a gas compressor station in Beijing as an example,equipment type,heat transfer medium type and buried pipe layout are determined according to geological and climatic characteristics of the station and by the design calculation method of underground heat exchanger,load and flow,to design and build the GSHP system in the station for the first time.In accordance with the relevant standard,system energy monitoring and energy saving effect analysis are carried out.Results show that the system can reach the energy saving rate up to 27.62% compared with the air source heat pump;the system can reach energy saving rate up to 63.81% compared with electric heaters;with significant energy-saving effects and considerable long-running economic returns,the system has application values.
Keywords:gas compressor station  ground source heat pump  underground heat exchanger  energy conservation monitoring
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号