首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于CFD的植物工厂管道通风模拟及优化
引用本文:吴晨溶,程瑞锋,方慧,杨其长,张晨.基于CFD的植物工厂管道通风模拟及优化[J].中国农业大学学报,2021,26(1):78-87.
作者姓名:吴晨溶  程瑞锋  方慧  杨其长  张晨
作者单位:中国农业科学院 农业环境与可持续发展研究所, 北京 100081; 农业农村部设施农业节能与废弃物处理重点实验室, 北京 100081
基金项目:宁夏回族自治区重点研发计划项目(2018BBF02012);中央级公益性科研院所基本科研业务费专项(Y2019XK21-01)
摘    要:针对植物工厂中传统通风模式难以实现内部气流均匀分布的问题,在满足合适的管孔径比情况下,通过计算设计了管道通风方案,利用计算流体力学CFD(Computational fluid dynamics)仿真软件对不同方案的作物冠层气流场进行模拟,探究管孔直径、管孔数量及进风口风速对作物冠层气流分布的影响,确定最佳管道通风方案...

关 键 词:植物工厂  管道通风  作物冠层  气流均匀性  计算流体力学(CFD)
收稿时间:2020/5/11 0:00:00

Simulation and optimization of air tube ventilation in plant factory based on CFD
WU Chenrong,CHENG Ruifeng,FANG Hui,YANG Qichang,ZHANG Chen.Simulation and optimization of air tube ventilation in plant factory based on CFD[J].Journal of China Agricultural University,2021,26(1):78-87.
Authors:WU Chenrong  CHENG Ruifeng  FANG Hui  YANG Qichang  ZHANG Chen
Institution:Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agriculture Sciences, Beijing 100081, China; Key Laboratory of Energy Conservation and Waste Management of Agriculture Structures of Ministry of Agriculture and Rural Affairs, Beijing 100081, China
Abstract:Aiming at the problem of uneven airflow distribution and tipburn appear frequently in the traditional ventilation mode, under the condition of satisfying the appropriate tube aperture ratio, CFD(Computational fluid dynamics)simulation software was adopted to simulate the airflow distribution of crop canopy under different cases designed. The effect of hole diameter, hole number and inlet air velocity on crop canopy air velocity distribution were explored and the optimal tube ventilation case was determined finally. The results showed that the airflow uniformity of all ventilation cases was better than that of traditional ventilation mode. By comparing and analyzing the proportion of the average air velocity on the surface of the crop canopy and the suitable area(the wind speed range was 0. 3-1. 0 m/s), it was found that the 25-holetube ventilation case with the inlet air velocity of 3 m/s was the best. The average air velocity on the surface of the crop canopy was 0. 55 m/s, and the suitable area accounted for 86. 1% of the total canopy surface area.
Keywords:plant factory  tube ventilation  canopy  airflow uniformity  computational fluid dynamics
本文献已被 CNKI 等数据库收录!
点击此处可从《中国农业大学学报》浏览原始摘要信息
点击此处可从《中国农业大学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏