首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高效液相色谱检测苯氧威含量
引用本文:黄安太,车军,石峰,赵科华.高效液相色谱检测苯氧威含量[J].广东农业科学,2007(7):76-77.
作者姓名:黄安太  车军  石峰  赵科华
作者单位:深圳市龙岗区无公害农产品质量监督检验站,广东,深圳,518172
摘    要:研究了苯氧威的高效液相色谱检测条件,指出以甲醇 水为流动相,用C18柱和紫外检测器分离测定苯氧威的标准偏差为0.063,变异系数为0.067%,平均回收率为99.16%,线性关系系数为0.9999.

关 键 词:苯氧威  高效液相色谱  检测
文章编号:1004-874X(2007)07-0076-02
修稿时间:2007-04-26

Determination of fenoxycarb by HPLC
HUANG An-tai,CHE Jun,SHI Feng,ZHAO Ke-hua.Determination of fenoxycarb by HPLC[J].Guangdong Agricultural Sciences,2007(7):76-77.
Authors:HUANG An-tai  CHE Jun  SHI Feng  ZHAO Ke-hua
Institution:Shenzhen Longgang Inspection Station of Non-pollution Agricultural Products, Shenzhen 518172, China
Abstract:It was introduced that the quantitative determination of fenoxycarb by reverse phase HPLC, using methanol and water as mobile phase,using C18 column and ultraviolet detector. The results show that the standard deviation ,the variation coefficient, the average recovery and liner correlation were 0.063, 0.067%, 99.16%, 0.9999.
Keywords:fenoxycarb  HPLC  determination