首页 | 本学科首页   官方微博 | 高级检索  
     检索      

LPCV牛舍夏季湿帘风机系统运行模拟分析
引用本文:吕慧洁,曹明,李景琦,丁蕊.LPCV牛舍夏季湿帘风机系统运行模拟分析[J].中国奶牛,2022(2):48-53.
作者姓名:吕慧洁  曹明  李景琦  丁蕊
作者单位:沈阳城市建设学院市政与环境工程系
摘    要:为研究LPCV牛舍夏季舍内环境变化规律,为LPCV牛舍提供合理的湿帘风机运行方案,本文以沈阳地区某六排低屋面横向通风牛舍为研究对象,采用计算流体动力学(Computational fluid dynamics,CFD)方法,分别在沈阳夏季设计工况和极端最热工况下对舍内环境进行三维数值模拟,分析两种工况条件下舍内的温度和...

关 键 词:低屋面横向通风牛舍  计算流体动力学  数值模拟  湿帘风机系统

Operation Simulation Analysis of Fan-pad System in LPCV Diary Cattle Barn in Summer
LV Hui-jie,CAO Ming,LI Jing-qi,DING Rui.Operation Simulation Analysis of Fan-pad System in LPCV Diary Cattle Barn in Summer[J].China Dairy Cattle,2022(2):48-53.
Authors:LV Hui-jie  CAO Ming  LI Jing-qi  DING Rui
Institution:(Department of Municipal and Environmental Engineering,Shenyang Urban Construction University,Shenyang 110167)
Abstract:In order to study the law of indoor environment change of LPCV dairy cattle barn in summer and provide the suitable fan-pad cooling system operating scheme. The object of study is a certain 6-row Shenyang low profile cross ventilated dairy cattle barn. Three-dimension computational fluid dynamics(CFD) method was carried out to simulate thermal condition inside the cattle building under design condition and extreme condition of Shenyang in summer, to analyse temperature and velocity distribution law inside the cattle building under both working conditions and get the operating scheme of fan-pad cooling system. Simulated results showed that while all fans were turned on and 20℃ room temperature water was used for wet pad spray water under the design condition, the indoor condition could satisfied the comfort requirements for cows. While all fans were turned on and wet pad spray water temperature drops to 16℃ under the extreme condition, the indoor condition could satisfied the comfort requirements for cows. With the air movement, temperature increased not exceeding 0.014 ℃ per meter in width dimension of Z=1.2 m and indoor mean velocity was not more than 1.92 m/s, air non-uniformity coefficient maximum was 59.86% under two working conditions. At the same time, the fan-pad cooling model can be applied to the ventilation system design of LPCV dairy cattle barn in other regions of China. According to the design parameters in different regions, the simulation analysis is carried out to determine the summer operation scheme of the ventilation system.
Keywords:Low profile cross ventilated  Computational fluid dynamics  Numerical simulation  Fan-pad system
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号