首页 | 本学科首页   官方微博 | 高级检索  
     检索      

东临复线水击保护实例分析
引用本文:韩春宇,黄春,陈飞,南兵.东临复线水击保护实例分析[J].油气储运,2008,27(2):53-55.
作者姓名:韩春宇  黄春  陈飞  南兵
作者单位:中石化管道储运分公司潍坊输油处
摘    要:东临复线配置有完善的水击压力保护系统,同时采取了压力泄放、顺序停泵、硬线停泵及水击超前保护等措施.通过对东临复线水击保护实例的分析,指出采取泵站独立压力保护系统和全线水击超前保护系统等多重保护措施,可有效防止严重水击工况对管道和设备的危害.

关 键 词:输油管道  水击保护  实例  分析
收稿时间:2007-01-17
修稿时间:2007年1月17日

Surge Protection Case for Dongying-Linyi Parallel Oil Pipeline
HAN Chunyu,HUANG Chun et al.Surge Protection Case for Dongying-Linyi Parallel Oil Pipeline[J].Oil & Gas Storage and Transportation,2008,27(2):53-55.
Authors:HAN Chunyu  HUANG Chun
Abstract:Dongying-Linyi Parallel Oil Pipeline is provided with perfect surge protection system and meanwhile some measures are taken such as pressure relief, sequential pump OFF-mode, "hardline" pump OFF-mode and leading surge protection for the pipeline. Through analyzing the surge protection case of Dongying-Linyi Parallel Oil Pipeline,it is pointed out that multi-measures taken based on an independent pressure protection system of a pump station and a whole line leading surge protection system can effectively protect the pipeline and its equipment from surge hazards.
Keywords:oil pipeline  surge protection  case of surge protection  surge analysis  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏