首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Carbon and nitrogen distribution in water-stable aggregates under two tillage techniques in Fluvisols of Owerri area, southeastern Nigeria
Authors:EU Onweremadu  VN Onyia  MAN Anikwe  
Institution:

aDepartment of Soil Science and Technology, Federal University of Technology, P.M.B. 1526, Owerri, Nigeria

bDepartment of Crop Science and Technology, Federal University of Technology, P.M.B. 01526, Owerri, Nigeria

cDepartment of Agronomy and Ecological Management, Enugu State University of Science and Technology, P.M.B. 01660, Enugu, Nigeria

Abstract:Organic matter influences soil structure and compactibility by binding soil mineral particles, reducing aggregate wettability, and influencing the mechanical strength of soil aggregates, which is the measure of coherence of inter-particle bonds. This work was carried out to examine how differences in water-stable aggregates influence the distribution of soil organic carbon and soil organic nitrogen under two tillage techniques minimum tillage (only planting holes were opened) and conventional tillage (raised beds, 30 cm high, prepared manually with traditional hoes)] in soils of a Fluvisol in Owerri, southeastern Nigeria. Three pedons were dug and studied for each of the tillage technique along a soil sequence. Soil organic carbon and soil organic nitrogen distribution in whole soil and in water-stable aggregates under minimum tillage and conventional tillage were determined for the soils. Soil organic carbon contents in water-stable aggregates (WSA) of the pedons varied according to method of tillage. The highest mean values of soil organic carbon were obtained from minimum tillage and in water-stable aggregates 4.75–2.00 mm (16.03 Mg C ha−1), 1.00–0.50 mm (14.06 Mg C ha−1) and water-stable aggregates 2.00–1.00 mm (13.99 Mg C ha−1) whereas under conventional tillage, water-stable aggregates 1.00–0.50 mm with soil organic carbon of 24.6 Mg C ha−1 had the highest soil organic carbon content. Soil organic carbon correlated significantly with mean weight diameter (r = 0.48; P = 0.05; n = 15), water-stable aggregates 4.75–2.00 mm (r = 0.73; P = 0.05; n = 15), water-stable aggregates 2.00–1.00 mm (r = 0.55; P = 0.05, n = 15), water-stable aggregates 1.00–0.50 mm (r = 0.44; P = 0.05; n = 15) whereas no relationship was found between soil organic carbon and water-stable aggregates 0.50–0.25 mm (r = 0.15; P = 0.05; n = 15) and water-stable aggregates <0.25 mm (r = 0.17; P = 0.05; n = 15) in soils under minimum tillage. There was a significant correlation (r = 0.45–0.58; P = 0.05; n = 14) between all water-stable aggregates classes studied and soil organic carbon in soils under conventional tillage. Mean values of soil organic nitrogen were higher in soils under minimum tillage with 4.75–2.00 mm and 2.00–1.00 mm aggregate classes having 1.64 Mg N ha−1 and 1.57 Mg N ha−1 soil organic nitrogen when compared to 1.01 Mg N ha−1 and 1.00 Mg N ha−1 in conventionally tilled soils of the same aggregate classes, respectively. Larger water-stable aggregate classes (4.75–2.00; 2.00–1.00) had slightly more soil organic nitrogen (22–26%) than smaller aggregate classes (1.00–0.50; 0.50–0.25; >0.25) with 14–24% soil organic nitrogen in minimum tilled soils. In soils under conventional tillage, 1.00–0.50 mm, 0.50–0.25 mm and <0.25 mm aggregate classes contributed more soil organic nitrogen (19.66–22.40%) to the soil whereas larger water-stable aggregate classes contributed 19.22% soil organic nitrogen. The proportion of soil organic carbon and total nitrogen retained in soils with higher percentage of water-stable aggregates are less likely to be lost through soil and wind erosion. The higher values of SOC in the whole soil and WSA classes less than 2.00 mm are indications of positive influence of SOC on the stability of these peds.
Keywords:Soil aggregation  Floodplain  Long-term experiment  Intercropping system  Tropical environment
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号