Gas-liquid chromatographic/mass spectrometric screening method for T-2 toxin in milk
Authors:G J Collins  J D Rosen
Abstract:A method for the analysis of T-2 toxin in milk is presented. Ethyl acetate extracts of milk samples which had been spiked with T-2 toxin were purified by thin layer chromatography and derivatized with N,O-bis(trimethylsilyl)acetamide to produce the T-2 toxin trimethylsilyl ether (T-2 toxin-TMS). N,O-bis(trimethylsilyl-d9)acetamide was used to make T-2 toxin d9-trimethylsilyl ether (T-2 toxin-d9 TMS) which was added to the derivatized milk extract as an internal standard. Samples were analyzed by combined gas-liquid chromatography/mass spectrometry using either electron impact ionization or chemical ionization mass spectrometry. In electron impact ionization analyses, simultaneous monitoring of the T-2 toxin-TMS fragment ion at m/z 436 and the T-2 toxin-d9TMS fragment ion at m/z 445 gave a T-2 toxin-TMS detectability estimated at 6 microgram/kg. In chemical ionization analyses, the T-2 toxin-TMS fragment ion at m/z 377 and the T-2 toxin-d9TMS fragment ion at m/z 386 were simultaneously monitored to give a T-2 toxin-TMS detectability estimated at 3 microgram/kg. Average recovery was 85% at 200 microgram/kg and 65% at 20 microgram/kg.