首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Computerized Methodology for Evaluating Drinking Water Treatment Technologies: Part I
Authors:Lo  Irene M C  Alok  Pota A
Institution:1. Department of Civil Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, P.R. China
2. Department of Civil Engineering, Kansas State University, Manhattan, USA
Abstract:A computer based system, Best Available Technology Evaluator (BATE), has been developed for the evaluating cost and performance of the best available technologies for removing volatile organic chemicals (VOCs) from drinking water. The treatment processes considered are air stripping tower (AST), and air stripping with off-gas control by gas phase granular activated carbon (GPGAC) and liquid phase granular activated carbon (LPGAC). BATE is unique in its ability to model multicomponents, optimise total cost for different process configurations and yield the best process design for a given VOC scenario. This paper, the first in a two-part series, highlights a new cost optimization method for the AST with GPGAC system and a technique for combining mathematical models for efficient process design of AST and GPGAC processes. Discussion of LPGAC simulation results and comparison of an LPGAC system with AST and GPGAC processes for a variety of VOC scenarios will follow in the next paper.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号