首页 | 本学科首页   官方微博 | 高级检索  
     检索      

婴幼儿配方乳粉中16 种多环芳烃含量测定
引用本文:陈同强,李灿,荆辉华,梁锋,徐文泱,唐文杰,邓鸣,李凯龙.婴幼儿配方乳粉中16 种多环芳烃含量测定[J].乳业科学与技术,2021,44(4):24-28.
作者姓名:陈同强  李灿  荆辉华  梁锋  徐文泱  唐文杰  邓鸣  李凯龙
作者单位:(河北省食品检验研究院,河北省食品安全重点实验室,河北 石家庄 050200)
基金项目:食品安全快速检测与溯源关键技术研究与示范项目(2020SK2128); 湖南省市场监督管理局科技计划项目(2020KJJH03;2021KJJH06;2021KJJH49)
摘    要:采用气相色谱-质谱法,建立同时测定婴幼儿配方乳粉中16 种多环芳烃含量的分析方法,并对网购45 份婴幼儿配方乳粉中多环芳烃的污染水平进行调查研究。通过优化前处理方法,考察方法的线性关系、精密度、加标回收率及检出限等参数,采用外标法定量。结果表明:该方法中16 种多环芳烃在1~100 ng/mL范围内均线性良好(r>0.999),检出限为0.01~0.10 μg/kg;5、10、50 μg/kg水平下的平均加标回收率为76.2%~103.1%,相对标准偏差均小于10%;调查的45 份婴幼儿配方乳粉样品中,0~6 月龄乳粉多环芳烃检出率为86.7%,含量为0~1.12 μg/kg,6~12 月龄乳粉检出率为80.0%,含量为0~0.75 μg/kg,12~36 月龄乳粉检出率为60.0%,含量为0~0.60 μg/kg。

关 键 词:气相色谱-质谱法  多环芳烃  婴幼儿配方乳粉  检出率  污染  

Determination of 16 Polycyclic Aromatic Hydrocarbons in Infant Formula
CHEN Tongqiang,LI Can,JING Huihua,LIANG Feng,XU Wenyang,TANG Weijie,DENG Ming,LI Kailong.Determination of 16 Polycyclic Aromatic Hydrocarbons in Infant Formula[J].JOURNAL OF DAIRY SCIENCE AND TECHNOLOGY,2021,44(4):24-28.
Authors:CHEN Tongqiang  LI Can  JING Huihua  LIANG Feng  XU Wenyang  TANG Weijie  DENG Ming  LI Kailong
Institution:(1.Hunan Provincial Key Laboratory of Food Safety Monitoring and Early Warning, Changsha 410111, China; 2.Hunan Institute of Food Quality Supervision Inspection and esearch, Changsha 410000, China; 3.Hunan Institute of Plant Protection, Changsha 410125, China)
Abstract:An analytical method was established by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of the contents of 16 polycyclic aromatic hydrocarbons (PAHs) in infant formula. This method was applied to survey the levels of PAHs pollution of 45 infant formula samples sold online. The sample pretreatment procedure was optimized and the figures of merit of the method including linearity, precision and spiked recovery were examined. The external standard method was used for quantitation. The linearity of the method was good in the concentration range of 1–100 ng/ mL (r > 0.999), and the limit of detection (LOD) was 0.01–0.10 μg/ kg. The average recoveries at spiked concentration levels of 5, 10 and 50 μg/kg were in the range of 76.2%–103.1%, and the relative standard deviation (RSD) for precision was less than 10%. The detection rate of PAHs was 86.7% from 15 infant formula samples for babies of 0–6 months at levels of 0–1.12 μg/kg. The detection rate of PAHs was 80.0% from 15 infant formula samples for babies of 6–12 months at levels of 0–0.75 μg/kg. The detection rate of PAHs was 60% from 15 infant formula samples for babies of 12–36 months at levels of 0–0.60 μg/kg.
Keywords:gas chromatography-mass spectrometry  polycyclic aromatic hydrocarbons  infant formula  detection rate  pollution  
本文献已被 CNKI 等数据库收录!
点击此处可从《乳业科学与技术》浏览原始摘要信息
点击此处可从《乳业科学与技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号