首页 | 本学科首页   官方微博 | 高级检索  
     检索      

连续流动分析法测定废水中的总氮
引用本文:龚敏,姜春燕,杨佩,陆劲松.连续流动分析法测定废水中的总氮[J].绿色大世界,2013(5):200-202.
作者姓名:龚敏  姜春燕  杨佩  陆劲松
作者单位:上海市崇明县环境监测站,上海202150
摘    要:探讨了连续流动分析法测定废水中总氮的方法。通过将测量量程扩大至20mg/L,对混浊的废水进行过滤处理,实验结果表明:该方法的相关系数达0.9999,方法检出限为0.02mg/L,加标回收率在99.5%~108%之间,RSD为0.2%~0.6%,可适用于废水中总氮的分析。

关 键 词:连续流动分析仪  总氮  废水

Determination of Total Nitrogen in Wastewater by Continuous Flow Analysis (CFA)
Authors:Gong Min  J iang Chunyan  Yang Pei  Lu Jingsong
Institution:(Environmental Monitoring Station of Chongming County, Shanghai 202150,China)
Abstract:This article basically discusses how to determine the total nitrogen in waste water by using Continuous Flow Analysis (CFA). The muddy water is filtered by enlarging the measuring range to 20 mg/L,and the test results show that the correlation coefficient of this method reaches 0. 9999 and MDL is 0.02mg/1, meanwhile,the standardized recovery rate is between 99.5% and 108% ,and RSD is between 0.2% and 0. 6 %. Thus it is proved that the method can be used to determine the total nitrogen in waste water.
Keywords:Continuous Flow Analyzer  total nitrogen  waste water
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号