首页 | 本学科首页   官方微博 | 高级检索  
     检索      


In Vitro Biomechanical Comparison of Solid and Tubular Interlocking Nails in Neonatal Bovine Femurs
Authors:STEVEN S TROSTLE DVM  MS    DAVID G WILSON DVM  Diplomate ACVS    R TASS DUELAND DVM  MS  Diplomate ACVS  MARK D MARKEL DVM  PhD  Diplomate ACVS
Institution:Comparative Orthopaedic Research Laboratory, Department of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin, Madison, WI;Marion duPont Scott Equine Medical Center, Leesburg, VA.
Abstract:This study biomechanically evaluates solid and tubular interlocking nails in bovine neonatal femurs. Paired femurs from 40 neonatal dairy calves were obtained for mechanical testing. Intact femurs and four combinations of experimentally manipulated femurs (intact or ostectomized femurs with either a solid or tubular interlocking nail) were tested in craniocaudal and lateromedial bending, eccentric axial compression, and external torsion to evaluate composite rigidity, local/gap stiffness, and load to failure (compression and torsion only). In torsional composite rigidity, femurs with tubular interlocking nails were more compliant than intact femurs or intact femurs with solid interlocking nails (P <.001). Ostectomized femurs with solid interlocking nails were similar to intact femurs with tubular interlocking nails. Within femurs with tubular interlocking nails, ostectomized femurs were more compliant than intact femurs (P <.0001). In craniocaudal and lateromedial bending rigidity, ostectomized femurs were more compliant than intact femurs, regardless of interlocking nail type (P <.001). Within ostectomized femurs, tubular interlocking nails were more compliant than solid interlocking nails in craniocaudal bending (P <.05) and there was a similar trend in lateromedial bending (P=.06). In eccentric axial compression, local/ gap stiffness was significantly greater in intact femurs compared with intact femurs with solid (48% of intact bone) or tubular (45% of intact bone) interlocking nails and ostectomized femurs with solid (18% of intact bone) or tubular (11 % of intact bone) interlocking nails (P <.0001). In torsional testing, local/gap stiffness was not significantly different between intact femurs and intact femurs with interlocking nails, but was significantly lower in ostectomized femurs with solid (2% of intact bone) and tubular (0.2% of intact bone) interlocking nails (P <.0001). In torsional and compressive failure testing, plastic deformation of the tubular interlocking nail occurred at the unoccupied screw hole at the ostectomy site before bone failure. Interlocking nails should be considered as an optional repair method for neonatal bovine femoral fractures. Until the actual physiological loading characteristics of neonatal calf femurs are measured, it is uncertain whether solid or tubular interlocking nails tested in this study will provide sufficient strength and stiffness to stabilize neonatal bovine femoral fractures and facilitate healing.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号