摘    要:本文叙述了采用高效液相色谱外标法,以甲醇一水作为流动相,用C18柱和紫外检测器(253nm),测定了噻虫嗪25%水分散粒剂的含量。结果表明,方法的标准偏差为0.046;变异系数为0.18%;平均回收率为99.65%。线性相关系数为0.9996。

关 键 词:噻虫嗪  高效液相色谱法  测定

Determination of Thiamethoxam 25% WG by HPLC
Yang Junzhu.Determination of Thiamethoxam 25% WG by HPLC[J].Pesticide Science and Administration,2009,30(6):41-43.
Authors:Yang Junzhu
Institution:YangJunzhu (Anhui Research Institute of Chemical Industry, Hefei 230041, China)
Abstract:A quantitative analytical method for Thiamethoxam 25% WC by HPLC, Using methanol+water =60+40 (V/V) as mobile phase, Kromasil C18 column and UV detector (253nm) was described . The results showed that the standard deviation, the coefficient of variation, the average recovery and the liner correlation of method were 0.046, 0.18%, 99.65% and 0.999 6 respectively.