首页 | 本学科首页   官方微博 | 高级检索  
     检索      

装配加温除湿系统的轻简装配式日光温室设计及性能试验
引用本文:周波,张义,方慧,杨其长,敖红达.装配加温除湿系统的轻简装配式日光温室设计及性能试验[J].农业工程学报,2016,32(11):226-232.
作者姓名:周波  张义  方慧  杨其长  敖红达
作者单位:1. 中国农业科学院农业环境与可持续发展研究所,北京100081; 农业部设施农业节能与废弃物处理重点实验室,北京 100081;2. 大连四通农用设施加工有限公司,大连,116000
基金项目:863计划资助课题(2013AA102407);公益性行业(农业)科研专项(201203002);基本科研业务费(BSRF201605);国家自然科学基金项目(51508560)。
摘    要:针对中国传统日光温室土地利用率低、建设成本高、墙体构造各异及温度和湿度环境难以调控等突出问题,该研究设计出一种轻简装配式日光温室,并配套了基于温室主动蓄放热原理的冬季夜晚加温和除湿系统,其温室骨架可与主动蓄放热系统结合为一体。研究结果表明:相比于传统砖墙日光温室,轻简装配式温室冬季夜晚温度提高4.5℃以上;采用基于主动蓄放热系统热能的除湿系统,可将温室夜间相对湿度降低14%,相对湿度控制在80%以下;该温室可实现整体式装配安装,大大减少了施工时间和安装成本,温室后墙厚度为166 mm,与后墙为600 mm厚的砖墙温室相比,墙体占地面积减少72%,显著提高了土地利用率。

关 键 词:温室  环境调控  轻简装配式  日光温室  加温  除湿
收稿时间:2015/10/14 0:00:00
修稿时间:2016/1/19 0:00:00

Performance experiment and design of simply assembled Chinese solar greenhouse equipped with heating and dehumidification system
Zhou Bo,Zhang Yi,Fang Hui,Yang Qichang and Ao Hongda.Performance experiment and design of simply assembled Chinese solar greenhouse equipped with heating and dehumidification system[J].Transactions of the Chinese Society of Agricultural Engineering,2016,32(11):226-232.
Authors:Zhou Bo  Zhang Yi  Fang Hui  Yang Qichang and Ao Hongda
Institution:1. Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China; 2. Key Lab of Energy Conservation and Waster Treatment of Agricultural Structures, Ministry of Agriculture, Beijing 100081, China,1. Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China; 2. Key Lab of Energy Conservation and Waster Treatment of Agricultural Structures, Ministry of Agriculture, Beijing 100081, China,1. Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China; 2. Key Lab of Energy Conservation and Waster Treatment of Agricultural Structures, Ministry of Agriculture, Beijing 100081, China,1. Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China; 2. Key Lab of Energy Conservation and Waster Treatment of Agricultural Structures, Ministry of Agriculture, Beijing 100081, China and 3. Dalian Si Tong Agricultural Facilities Processing Co., LTD, Dalian 116000, China
Abstract:Traditional Chinese solar greenhouse has thick north wall and its structure is non-standard, in which crop yield is lower because of the lack of automatic equipment for controlling the inside temperature and humidity. In order to solve this problem, we designed a simply assembled Chinese solar greenhouse that was equipped with heating and dehumidification system. In this study we presented 2 simply assembled Chinese solar greenhouses with active heat storage-release systems as the experiment greenhouses. One of them was also equipped with dehumidification system. Each greenhouse was 33 m long and 8 m wide with 3.8 m ridge height, 3.2 m height and 0.166 m thickness of the north wall. The wall of simply assembled greenhouse was composed of 2 fiber cement boards and a polystyrene board in between. A traditional solar greenhouse with brick wall using active heat storage-release system was chosen to be a reference greenhouse. It was 60 m long and 8 m wide with 3.8 m ridge height, 2.3 m height and 0.58 m thickness of the north wall. Compared with the brick wall, simply assembled Chinese solar greenhouse could save 72% of land resources. Steel frames of the experiment greenhouse were assembled together. It saved much more time to build a simply assembled Chinese solar greenhouse. All greenhouse crops were tomatoes planted on October 20th, 2014. Active heat storage-release system and dehumidification system were active automatically at night during the experiment. Active heat storage-release system was a heat-energy storage and release system by using water as the medium. During the day time (from 09:00 to 16:00) this system was used to store solar energy. During the nighttime (from 00:00 to 08:00), it released the energy into greenhouse for increasing the indoor temperature. In the experiment the system increased the indoor temperature by 4.5℃ at night compared with the traditional solar greenhouse. And the average air temperature was 1.3℃ higher in the simply assembled Chinese solar greenhouse than that in the traditional solar greenhouse combined with active heat storage-release system, which was because of higher insulation of the wall material. On cloudy day, the active heat-release system also improved the indoor temperature by 1.1℃. The dehumidification system had an air duct on the floor along the south-facing roof that distributed the outside air from a ventilator installed in the system box. This box contained the water-to-air heat exchanger, and 2 electrical heaters. The cold, dry air outside was heated by warm water from the water tank through a heat exchanger. Heat energy got from the warm water was supplied by the active heat storage-release system. A manual valve was used to control the air speed and 2 automatic valves were used to control the inlet of outside air. The dehumidification system could be activated from 18:00 to 08:30 in the next morning. When the inside relative humidity was higher than 85%, water went through the heat exchanger while the ventilator was switched on. When the indoor air temperature would drop below 8℃, the dehumidification system would switch off for preventing further cooling of the greenhouse by the cold air outdoor. During dehumidifying process, the first electric heater would be switched on when the water temperature was below 25℃. The second would work when the water temperature was below 20℃. During the experiment, the dehumidification system reduced the indoor relative humidity by 14% compared with the traditional solar greenhouse. During the dehumidification process, the energy consumption of the water pump and ventilator was 218.3 kJ/m2 per day. The energy supplied by the electric heaters was 643.6 kJ/m2 per day assuming that the energy conversion efficiency was 100%. The heat energy supplied by the active heat storage-release system was 639.4 kJ/m2 and its consumption was 153.4 kJ/m2 per day on average. It was expected that the electric heaters could be eliminated if the active heat storage-release system could be scaled up to provide an additional heat energy of 643.6 kJ/m2 per day. For a commercial greenhouse, it was important to improve the performance of the active heat storage-release system to get more solar energy and reduce the additional energy input. A more energy-efficient way of auxiliary heating was necessary in case of continuous cloudy days. By the financial analyses, the cost of brick wall greenhouse was 491.7 yuan/m2, and the simply assembled greenhouse was 334.5 yuan/m2. The biggest difference was from the charge of north wall. In conclusion, the simply assembled greenhouse with heating and dehumidification equipment saves much land resource, and has better indoor environment and less cost.
Keywords:greenhouses  environmental regulations  simply assemble  Chinese solar greenhouse  active heat storage-release system  dehumidification
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《农业工程学报》浏览原始摘要信息
点击此处可从《农业工程学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号