Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.  相似文献   

2.
Objective This study was conducted to evaluate the performance of a new veterinary oscillometric noninvasive blood pressure (NIBP) monitor in anesthetized dogs. Study design Assessment was made to determine how closely indirect measurements were associated with direct measurements, and if there were statistically significant differences between the measurements by site. Animals Six mongrel dogs weighing 27.8 ± 2.9 kg. Methods Dogs were anesthetized with thiopental and maintained with isoflurane, which was delivered with controlled ventilation. Direct pressure measurements were obtained via a percutaneously placed arterial catheter. A range of systolic arterial pressures (SAP) were achieved by changing the isoflurane concentrations. Sites of cuff placement for indirect measurements were identified as metacarpus, metatarsus, and anterior tibial. Results At pressures below 80 mm Hg, indirect systolic measurements averaged 4 ± 3 mm Hg, higher than the direct values. At normal and high levels, indirect systolic measurements underestimated direct values by 18 ± 6 and 23 ± 6 mm Hg, respectively. Diastolic and mean pressure measurements followed the same trend, with indirect values being lower than the direct arterial pressures. Systolic, diastolic and mean arterial pressure measurements differed by cuff‐placement site. Conclusions When analyzed by site and level, indirect systolic and mean arterial blood pressures during hypotension were essentially the same as direct pressures. However, at pressures within the normal or high range, indirect measurements underestimated the direct pressures. Clinical relevance Noninvasive blood pressure measurements with a new oscillometric monitor provided an excellent means of detecting arterial hypotension in anesthetized dogs. The metatarsal site for cuff placement was slightly better than the metacarpal or anterior tibial site, considering that the regression line was closest to complete equality between the indirect and direct measurements for SAP.  相似文献   

3.
Adaptation of human oscillometric blood pressure monitors for use in dogs   总被引:2,自引:0,他引:2  
Two digital oscillometric human blood pressure measuring devices were modified and evaluated as blood pressure monitors in 12 healthy anesthetized dogs. Direct arterial pressures were measured via cannulation of the dorsal pedal artery and were correlated with indirect measurements through an inflatable cuff placed over the dorsal pedal artery below the hock joint of the contralateral limb. Direct and indirect measurements were compared for systolic, diastolic, and calculated mean arterial pressures. Blood pressure ranges between 215/145 mm of Hg and 65/30 mm of Hg were obtained, using combinations of halothane, phenylephrine, calcium, and IV administered fluids. Machine A was found to be insufficient for clinical application, on the basis of correlation coefficients between direct and indirect pressures of 0.78, 0.65, and 0.74 for systolic, diastolic, and mean arterial pressures, respectively. Higher correlation coefficients between direct and indirect pressures (0.77, 0.87, and 0.87, respectively) were obtained with machine B. The results of the study reported here suggest machine B may be an effective blood pressure monitoring device in anesthetized dogs.  相似文献   

4.
OBJECTIVES: To obtain reference arterial blood pressure values from Kangal dogs, a local giant breed found in Turkey. METHODS: Arterial blood pressure measurements were obtained from 48 healthy Kangal dogs using oscillometric and Doppler techniques. The ages of the dogs ranged from two to 96 months, with a mean (sd) age of 36 (16) months. RESULTS: The effect of age on systolic, diastolic and mean arterial pressures determined by the oscillometric technique and on systolic pressure determined by the Doppler technique was significant (P<0.001). Blood pressure was found to be higher in mature dogs compared with that in immature dogs. The effect of sex and the interaction between age and sex were not significant (P>0.05). There was a direct relationship between age and oscillometric systolic, diastolic and mean arterial pressures and Doppler systolic arterial blood pressure both in the whole group and the immature group (P<0.05). Correlation between age and systolic arterial blood pressure measured either by oscillometric or Doppler techniques was not significant in the mature group. CLINICAL SIGNIFICANCE: The Kangal dog is bred in various countries including Turkey. It is known that giant breed dogs, such as the Kangal dog, are predisposed to cardiovascular disease. Canine arterial blood pressure values are highly breed and age dependent, so a reference value for any other breed is inappropriate for Kangal dogs. Therefore, it is important to measure arterial blood pressure of Kangal dogs.  相似文献   

5.
Objectives — (1) To determine the usefulness of one specific oscillometric monitor for making indirect measurements of arterial pressure in cats. (2) To determine the difference between two specific cuff placement sites. (3) To determine if clipping the hair beneath the cuff has an affect on the accuracy of oscillometric blood pressure determination.
Study Design — Prospective study comparing the accuracy of the Datascope Passport (Data-scope Corp, Paramus, NJ) with concurrent invasive measurements.
Animals — Six anesthetized domestic felines weighing 4.5 to 5 kg.
Methods — The direct arterial pressure was measured using a cannula placed in the right common carotid artery. Oscillometric cuffs of appropriate size were placed on both thoracic limbs distal to the elbow and both pelvic limbs distal to the stifle. The hair in the areas of cuff placement on the right limbs was clipped circumferentially. Measurements of systolic, diastolic, and mean arterial pressure (MAP) were taken for each site during normotension, hypotension, and hypertension. Comparisons between indirect and direct measurements were made using a parametric analysis of method comparison.
Results — No significant differences were noted when die clipped limbs were compared with the corresponding limbs which were left undipped ( P >.378) or when the thoracic limb measurements were compared widi those of the pelvic limb ( P >.088). There were significant differences ( P <.002) between the two pressure measurement methods for the systolic, diastolic, and mean arterial pressures over all three pressure ranges.
Conclusions — The Datascope Passport did not accurately estimate the invasively measured arterial pressure.
Clinical Relevance — Use of noninvasive blood pressure monitoring equipment is increasing in use in veterinary medicine, and the accuracy of one specific monitor is reported.  相似文献   

6.
Arterial blood pressure measurements were obtained from 158 healthy Irish wolfhounds using the oscillometric technique to establish reference values for the breed. In contrast to other sight hounds, Irish wolfhounds have low arterial blood pressure. Mean systolic pressure for the group was 116.0 mm Hg. Mean diastolic pressure was 69.2 mm Hg, and the mean value for mean arterial pressure was 87.8 mm Hg. Blood pressure measurements were higher in older wolfhounds than in young dogs. There was no difference between systolic and mean arterial blood pressures in lateral recumbency compared to standing position. However, diastolic pressure was slightly lower when standing. Calm dogs had lower pressure than anxious wolfhounds. There was a significant interaction between the effects of age, gender, and mood on systolic, diastolic, and mean arterial blood pressure values.  相似文献   

7.
OBJECTIVE: To examine the agreement between direct arterial blood pressure measurements obtained from 2 arteries and indirect blood pressure measurements obtained with an oscillometric blood pressure monitor (OBPM) during normotension and phenylephrine-induced hypertension in dogs. ANIMALS: 16 male Beagles. PROCEDURES: In anesthetized dogs, arterial catheters were placed in the lingual and dorsal pedal arteries for measurement of arterial blood pressure. A blood pressure cuff was placed on either the dog's fore- or hind limb and connected to an OBPM. Systolic, diastolic, and mean arterial blood pressures (SAP, DAP, and MAP, respectively) were recorded from both arteries and the OBPM every 5 minutes for 30 minutes (baseline), during a 30-minute period in which dogs received a phenylephrine infusion IV to induce hypertension, and for 30 minutes after discontinuation of the infusion. Mean differences in blood pressure values and confidence intervals were calculated to compare the indirect and direct measurement techniques. RESULTS: In dogs, oscillometry underestimated SAP during normotension, and the difference between oscillometric and direct measurements increased during hypertension. Oscillometry underestimated DAP, but the difference between oscillometric and direct measurements decreased during hypertension. There was close agreement among techniques for MAP determinations. Biases between direct measurements and OPBM blood pressure values measured from dogs' forelimbs or hind limbs were not significantly different. CONCLUSIONS AND CLINICAL RELEVANCE: In normotensive dogs, oscillometric measurements of MAP and SAP agreed more closely with direct arterial pressure measurements than oscillometric estimates of DAP. Oscillometric measurement of MAP was accurate during both normotension and hypertension in dogs.  相似文献   

8.
Objective: To investigate the agreement between indirect oscillometric and direct blood pressure measurement in the equine neonate. Design: Prospective observational study. Setting: University Veterinary Teaching Hospital. Animals: Ten crossbred foals of 30–46 hours of age. Interventions: Six animals (Group 1) were anesthetized. Four animals (Group 2) were restrained on a mat. All animals were instrumented with a catheter in the greater metatarsal artery and an oscillometric blood pressure cuff over the coccygeal artery. Blood pressure was varied with dobutamine, phenylephrine, nitroprusside, and increased depth of anesthesia (Group 1) or dopamine (Group 2). Measurements and main results: Simultaneous direct and indirect blood pressure measurements were obtained from the greater metatarsal artery and the coccygeal artery, respectively. There was good agreement between the 2 methods for mean and diastolic blood pressures in both groups, but not for systolic pressure. The agreement was best in mean blood pressure of anesthetized foals (mean bias –1.07; limits of agreement – 9.39, 7.25 mmHg). Conclusions: Indirect oscillometry appears to be an acceptable method for measuring mean arterial blood pressure in both anesthetized and conscious neonatal foals, and may be a valid method of monitoring critically ill foals.  相似文献   

9.
Objective To use the American College of Veterinary Internal Medicine (ACVIM) validation criteria to evaluate the performance of high definition oscillometric (HDO) and Doppler blood pressure measurement techniques against invasive blood pressure measurements in anaesthetized dogs. Study design Prospective clinical study. Animals Twenty client‐owned dogs. Materials and Methods Invasive blood pressure was measured using a catheter inserted into a pedal artery and an electronic transducer. The sites of cuff placement for the HDO measurements were the mid antebrachium or the proximal tail and, for the Doppler technique, the distal tibia. Agreement between invasive and non‐invasive blood pressure measurements was estimated by the Bland–Altman method. Results Only 10% and 34% of Doppler measurements were within 10 and 20 mmHg of invasive blood pressure values, respectively. The Doppler device failed to meet the ACVIM validation criteria for blood pressure measurement devices. The best agreement between HDO and invasive blood pressure measurement technique was observed for mean arterial blood pressure (MAP); 67% and 95% of readings were within 10 and 20 mmHg of invasive blood pressure values respectively. In addition, 52% and 87% of diastolic arterial blood pressure (DAP) measurements were within 10 and 20 mmHg of invasive readings. High definition oscillometric readings did not meet ACVIM recommended limits for SAP. Conclusion and clinical relevance The Doppler technique overestimated and the HDO device showed limited agreement with invasive blood pressure measurement in anaesthetized dogs. High definition oscillometry met most of the ACVIM requirements for MAP and DAP while the Doppler technique did not.  相似文献   

10.
The objectives of this study were to assess, in anesthetized neonatal foals, the accuracy of 2 automated indirect oscillometric monitors for measurement of mean arterial pressure (MAP), to determine the optimal site of cuff placement for MAP monitoring, and to determine the relationship between arterial blood pressure and cardiac output. Ten neonatal foals were anesthetized and instrumented with a catheter in the metatarsal artery for direct MAP monitoring and measurement of cardiac output by lithium dilution. Concurrent MAP measurements were obtained with Cardell and Dinamap oscillometric monitors with cuffs placed at 3 different sites (coccygeal, metatarsal, and median arteries). Blood pressure was manipulated by varying the depth of anesthesia and by administration of dobutamine or phenylephrine. A statistically significant (P = .025) interaction was found between the type of monitor and cuff placement site. With the Cardell monitor, placement of the cuff over the coccygeal artery resulted in a significantly lower bias than placement over the median or dorsal metatarsal artery (P < .0001 and P = .0149, respectively). No significant difference in bias was found with cuff placement site when using the Dinamap monitor. The correlation coefficient (r) between MAP and cardiac output was 0.47. Indirect oscillometry with a cuff placed over the coccygeal artery or dorsal metatarsal artery is an acceptable method for measuring MAP in foals. Blood pressure does not correlate well with cardiac output in anesthetized foals.  相似文献   

11.
OBJECTIVE: To determine whether there was an association between hypertensive retinopathy and high systolic, diastolic, and mean arterial blood pressures in cats. ANIMALS: 181 cats. PROCEDURE: Systolic, diastolic, and mean arterial blood pressures were measured by use of a noninvasive oscillometric technique. The range of blood pressure measurements in healthy cats from various age groups was determined. Associations among systolic, diastolic, and mean arterial blood pressure; hypertensive retinopathy; hyperthyroidism; left ventricular cardiac hypertrophy; chronic renal failure; and serum biochemical abnormalities were determined. RESULTS: All blood pressure measurements increased with age in healthy cats. The frequency of hypertensive retinopathy also increased with age and with blood pressure, and hypertensive retinopathy was particularly found in cats with systolic blood pressures > 168 mm Hg. There was an increased risk for hypertensive retinopathy in cats that were female, > 10 years old, and neutered. The risk of chronic renal failure also increased as blood pressure, particularly systolic blood pressure, increased. CONCLUSIONS AND CLINICAL RELEVANCE: Hypertensive retinopathy was common in cats > or = 10 years of age and was associated with systolic blood pressures > 168 mm Hg when measured by the noninvasive oscillometric technique.  相似文献   

12.
Objective To compare arterial blood pressure measurements obtained from the femoral and auricular arteries in anaesthetized pigs. Study design Prospective experimental study. Animals Fifteen female Large White pigs were used weighing 21.3 ± 2.3 kg. Methods The pigs were anaesthetized with tiletamine/zolazepam and xylazine administered intramuscularly, and anaesthesia maintained with isoflurane delivered in oxygen/nitrogen. Arterial oxygen partial pressures were maintained between 11.3 and 13.3 kPa and PaCO2 between 4.6 and 6.0 kPa. Monitoring included electrocardiogram, capnography and invasive blood pressure. The auricular and femoral arteries were catheterized for continuous systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) measurements. Measurements were recorded every 15 minutes. Statistical analysis involved a Bland–Altman plot analysis. Results The mean difference ± confidence intervals between the femoral and the auricular arterial diastolic, systolic and mean blood pressure measurements during hypotension were 2 ± 7, 2 ± 5 and 2 ± 5 mmHg respectively. In conditions of normotension mean difference ± confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 ± 5, 3 ± 7 and 4 ± 4 mmHg respectively. In conditions of increased arterial blood pressure, mean difference ± confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 ± 5, 3 ± 8 and 4 ± 4 mmHg respectively. Conclusion Auricular artery catheterization is easier and quicker to perform. Pressure measurements from the auricular artery compared well with the femoral artery. Clinical relevance We found that auricular arterial blood pressures were similar to femoral arterial values under the conditions of this experiment. We did not test extremes of blood pressure or significant alterations in body temperature.  相似文献   

13.
To assess the accuracy and precision of indirect measurements of systemic arterial blood pressure (BP), results obtained with an oscillometric device (BPo) and a Doppler ultrasonic device (BPud) were compared with those obtained by direct radiotelemetry (BPrt) in 12 conscious beagles. The correlation between indirectly obtained and directly measured values for BP parameters ranged widely for the different indirect methods and sites of cuff placement, with R2 between 0.001 and 0.901. Both indirect methods underestimated all BP parameters, the degree of underestimation increasing at higher values for the BP. The highest correlation occurred when estimates were the average of 5 values consecutively obtained with the oscillometric device and cuff placement at the coccygeal artery (R2 = 0.854 for mean BPo, 0.886 for systolic BPo, and 0.901 for diastolic BPo; P < 0.0001 for all parameters) or with the ultrasonic Doppler device at the metatarsal arteries (R2 = 0.810 for systolic BPud; P < 0.0001). Multiple consecutively obtained values are advised, as this approach improves the reliability of indirect BP measurements. The strong correlation between directly measured values and estimates derived as the average of 5 consecutive indirectly obtained values indicates that the latter approach provides a useful estimate of BP in conscious dogs and is likely to be useful in monitoring disease progress and treatment in dogs with abnormal BP.  相似文献   

14.
The accuracy of an oscillometric blood pressure monitor (Vet/BP 6000, Sensor Devices, Inc., Waukesha, WI) was assessed in 13 anesthetized horses undergoing a variety of clinical procedures. The oscillometric blood pressure measurements using a cuff placed around the base of the tail were compared to simultaneously recorded direct pressure readings. One hundred nine sets of blood pressure measurements were recorded. In addition the pulse rates, as determined by digital palpation and oscillometric measurement, the time required for an oscillometric measurement, and the number of attempts required by the oscillometric unit were recorded. The average difference between the direct and oscillometric blood pressures were 18, 9, and 11 mmHg for the systolic, diastolic and mean arterial blood pressures, respectively. The oscillometric and direct pressure measurements showed significant correlation with a correlation coefficient of 0.93 for the mean arterial pressure. The oscillometrically determined pulse rate (average-33 pulses/min) was significantly different than the pulse rate determined by palpation (average-33.4 pulses/minute) but the difference was less than one. The average time required for a determination was 69 seconds and the average number of attempts required was 1.02 per determination.  相似文献   

15.
Two non-invasive blood pressure (NIBP) devices (oscillometry and Doppler) were compared to invasive blood pressure using a Bland–Altman analysis, in anesthetized and conscious dogs. When considering the systolic arterial pressure only during general anesthesia, both NIBP devices slightly underestimated the systolic arterial blood pressure however the precision and the limits of agreement for the Doppler were of a greater magnitude. This indicates a worse clinical performance by the Doppler. The performance of both NIBP devices deteriorated as measured in conscious animals. In general, for the oscillometric device, determination of invasive diastolic and mean arterial pressures was better than the invasive systolic arterial pressure. Overall, the oscillometric device satisfied more of the criteria set by the American College of Veterinary Internal Medicine consensus statement. Based upon these results, the oscillometric device is more reliable than the Doppler in the determination of blood pressure in healthy medium to large breed dogs.  相似文献   

16.
Objective —To determine the accuracy of three indirect blood pressure monitoring techniques (oscillometric technique [OS], Doppler [DOP], and optical plethysmography [OP] [blood pressure determined with a pulse oximeter waveform]) when compared with direct arterial pressure measurement in cats. Study Design —Prospective study. Animal Population —Eight healthy (five female, three male), domestic short-hair cats, weighing 3.5 ± 0.8 kg Methods —Cats were anesthetized with isoflurane. The inspired concentration of isoflurane was adjusted to produce mild hypotension (80 to 100 mm Hg direct systolic), moderate hypotension (60 to 80 mm Hg direct systolic), and severe hypotension (<60 mm Hg direct systolic). Indirect pressure measurements were obtained from the thoracic limb and compared with concurrent direct measurement using regression analysis and a modification of Bland and Altman's technique. Results —All three techniques underestimated systolic pressure. OS produced the best prediction of systolic pressure with a bias ± precision of -15.9 ± 8.1 mm Hg. DOP and OP were relatively inaccurate with a bias ± precision of -25 ± 7.4 mm Hg and -25 ± 7.5 mm Hg. All three techniques correlated well with direct pressure with r values of 0.81, 0.88, and 0.88 for OS, DOP, and OP. DOP and OP provided an accurate prediction of direct mean arterial pressure with a bias ± precision of -0.8 ± 6 mm Hg and 0.6 ± 5.5 mm Hg. Correlation was good between DOP and mean arterial pressure with r = 0.89. Correlation was also good between OP and mean arterial pressure with r = 0.90. Conclusions —OS provided the most accurate prediction of direct systolic pressure. DOP and OP provided a good prediction of mean arterial pressure in the cat. Clinical Relevance —All three of these techniques are useful for detecting trends. Direct monitoring of blood pressure should be considered if accurate blood pressure measurement is required.  相似文献   

17.
The purpose of this study was to qualify and quantify the femoral artery blood flow by duplex Doppler ultrasonography (DDU) in healthy dogs, before and after the administration of a combination of acepromazine maleate and buprenorphine hydrochloride (ACP-BPN). Seven healthy adult mongrel dogs and three adult beagles were used. Heart rate, arterial blood pressure and measurement of femoral artery blood flow by DDU were also recorded. The DDU measurements were: femoral artery diameter (FAD), peak systolic velocity (PSV), early retrograde (EDV) and end diastolic velocities (EnDV), mean velocity (BMV), pulsatility index (PI), flow velocity integral (FVI) and femoral blood flow (FBF). After 30 min, combination ACP-BPN was administered intramuscularly, and all the measurements were recorded again. The ACP-BPN protocol induced a significant decrease in systolic, mean, and diastolic arterial blood pressure, and heart rate. A significant increase in peak systolic velocity and integral flow velocity integral of the femoral blood were obtained. The Doppler spectra of the blood flow in the femoral artery revealed a spectral dispersion pattern after ACP-BPN administration in all the dogs. These results demonstrate that despite quantitative and qualitative changes, the overall femoral blood flow (FBF) is not significantly modified.  相似文献   

18.
An electronic sphygmomanometer which functions on oscillometric principles, was used to measure arterial blood pressure in foals. Its accuracy was assessed by comparison with results obtained by direct measurement in anaesthetised pony foals, aged 34 to 64 days. Correlations between data obtained by the two methods were highly significant but the sphygmomanometric readings were consistently lower than those obtained by direct measurement. An equation was derived from the pooled values for mean, systolic and diastolic pressure measurements. This was used as a correction factor when the oscillometric method was employed in the field on Thoroughbred foals, during the first three days post partum, and on pony foals during the first day only. There were no significant differences between systolic, diastolic and mean values in Thoroughbreds on Days 1, 2 or 3 after birth. Measurements recorded on the first day after foaling were significantly lower (P less than 0.025) in ponies than in Thoroughbreds. Blood pressure measurements in Thoroughbreds and ponies were substantially higher than those reported previously using the ultrasonic Doppler technique.  相似文献   

19.
Objectives : To evaluate high-definition and conventional oscillometry in comparison with direct blood pressure measurements in anaesthetised dogs. Methods : Eight simultaneous readings for systolic, diastolic and mean pressure were obtained directly and with each of two devices in nine anaesthetised dogs. Measurement procedure and validation were based on the 2007 ACVIM guidelines. Results : Sixty-three simultaneous readings were evaluated for each device and direct measurements. The mean differences (bias) to direct values were within 10 mmHg for both devices although bias for systolic and diastolic blood pressures was higher for Memodiagnostic. The standard deviations of differences (precision) were within 15 mmHg for Dinamap but exceeded for Memodiagnostic. Correlation coefficients were higher for Dinamap than Memodiagnostic but both failed to reach a correlation of 0·9. Over 50% of values lay within 10 mmHg of direct measures for both devices, but this percentage was greater for Dinamap than Memodiagnostic. Over 80% of values lay within 20 mmHg of direct measures for Dinamap but not for Memodiagnostic. Clinical Significance : Both devices failed to meet ACVIM guideline validation. However, Dinamap only failed with regards to correlation. Memodiagnostic failed on several requirements, and based on poor correlation, accuracy and precision, this device cannot be currently recommended for dogs under anaesthesia.  相似文献   

20.
OBJECTIVE: To determine accuracy of an oscillometric blood pressure monitor used over a wide range of pressures in anesthetized cats. DESIGN: Prospective study. ANIMALS: 6 healthy cats. PROCEDURE: 4 female cats and 2 male cats that weighed 2.7 to 4.5 kg (5.9 to 9.9 lb) and were 2 to 8 years old were anesthetized. Blood pressure was measured directly with an arterial catheter placed in the right femoral artery and indirectly from the left antebrachium by use of an oscillometric monitor. A series of diastolic arterial pressure (DAP), mean arterial pressure (MAP), and systolic arterial pressure (SAP) measurements were obtained during hypotension, normotension, and hypertension. Values obtained indirectly and directly were compared. RESULTS: The oscillometric monitor was accurate for DAP and MAP throughout the entire pressure range and met the standards of the Association for the Advancement of Medical Instrumentation (mean +/- SD difference from values obtained directly, < or = 5 +/- 8 mm Hg). The SAP was increasingly underestimated with increasing overall pressure; mean differences from direct measurements were -5.2, -12.1, and -17.7 mm Hg during hypo-, normo-, and hypertension, respectively. Standard deviations for SAP were all < or = 8 mm Hg. The monitor gave readings during all attempts. The direct blood pressure recording system appeared to perform well with neither under- nor overdamping. CONCLUSIONS AND CLINICAL RELEVANCE: Except for a minor underestimation of SAP during normo- and hypertension, the oscillometric monitor yielded reliable and easily obtainable blood pressure measurements in anesthetized cats.  相似文献   