首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 665 毫秒
1.
Objective – To determine the accuracy and precision of an oscillometric noninvasive blood pressure device as a predictor of invasive direct blood pressure in healthy anesthetized hypotensive and normotensive dogs. Design – Prospective observational study. Setting – University teaching hospital. Animals – Eight crossbred adult dogs. Interventions – Anesthesia was induced with propofol and maintained with isoflurane. A catheter was placed in the dorsal pedal artery to record systolic, mean, and diastolic arterial blood pressures (aSAP, aMAP, and aDAP, respectively). The noninvasive blood pressure device cuff was placed around the contralateral front limb to record noninvasive systolic, mean, and diastolic blood pressure (nSAP, nMAP, and nDAP). Two states of blood pressure (BP) were studied: baseline state was established by keeping end‐tidal isoflurane concentration at 1.2±0.1%. The hypotensive state was achieved by maintaining the same isoflurane concentration while withdrawing approximately 40% of the animal's blood volume until aMAP was stable at approximately 40 mm Hg. At the end of the study, blood was returned to the animal and it was allowed to recover from anesthesia. Measurements and Main Results – Agreement between the direct and indirect BP measurements was determined by the Bland‐Altman method. The SAP and MAP but not DAP bias varied significantly between each BP state. Normotensive absolute biases (mean [SD]) for SAP, MAP, and DAP were ?14.7 mm Hg (15.5 mm Hg), ?16.4 mm Hg (12.1 mm Hg), and ?14.1 mm Hg (15.8 mm Hg), respectively. Absolute biases during the hypotensive state for SAP, MAP, and DAP were ?32 mm Hg (22.6 mm Hg), ?24.2 mm Hg (19.5 mm Hg), and ?16.8 mm Hg (17.2 mm Hg), respectively. Conclusion – The oscillometric device was not reliably predictive of intra‐arterial BP during hypotension associated with acute hemorrhage.  相似文献   

2.

Objective

To assess the validity and reliability of Doppler ultrasonography (DOP) as compared with invasive arterial blood pressure measurements in anaesthetized dogs weighing less than 5 kg.

Study design

Controlled, prospective, clinical study.

Animals

A total of 41 privately owned dogs weighing less than 5 kg.

Methods

The dogs were anaesthetized, and an intra-arterial catheter was placed aseptically in the dorsal pedal artery of the pelvic limb to perform invasive blood pressure (IBP) measurement. The contralateral metatarsal surface of the foot was clipped in order to perform DOP. Both techniques were used to record blood pressure measurements every 5 minutes during surgical procedures. The blood pressure measurements were categorized into two groups: hypotensive [mean arterial pressure (MAP) < 60 mmHg] and normotensive (MAP between 60 and 120 mmHg). A linear mixed model was used to compare the DOP and IBP values. The results were evaluated according to the requirements of the American College of Veterinary Internal Medicine (ACVIM) guidelines for the validation of devices.

Results

DOP provided higher values compared to the systolic arterial blood pressure (SAP) and MAP of IBP measurements. The closest agreement between the two techniques was found for SAP; the bias was 8.8, and limits of agreement (LOA) were –32.9 and 50.4. Similar results were observed when the IBP technique was categorized. The closest agreement was for SAP in animals categorized as normotensive; the bias was 8.2, and LOAs were –32.8 and 49.2. The level of agreement between DOP and IBP did not meet the ACVIM recommendations.

Conclusions and clinical relevance

Our results suggest there is poor agreement between DOP and IBP measurements in anaesthetized dogs weighing less than 5 kg. Hence, the use of DOP in these animals could be misleading.  相似文献   

3.
Adaptation of human oscillometric blood pressure monitors for use in dogs   总被引:2,自引:0,他引:2  
Two digital oscillometric human blood pressure measuring devices were modified and evaluated as blood pressure monitors in 12 healthy anesthetized dogs. Direct arterial pressures were measured via cannulation of the dorsal pedal artery and were correlated with indirect measurements through an inflatable cuff placed over the dorsal pedal artery below the hock joint of the contralateral limb. Direct and indirect measurements were compared for systolic, diastolic, and calculated mean arterial pressures. Blood pressure ranges between 215/145 mm of Hg and 65/30 mm of Hg were obtained, using combinations of halothane, phenylephrine, calcium, and IV administered fluids. Machine A was found to be insufficient for clinical application, on the basis of correlation coefficients between direct and indirect pressures of 0.78, 0.65, and 0.74 for systolic, diastolic, and mean arterial pressures, respectively. Higher correlation coefficients between direct and indirect pressures (0.77, 0.87, and 0.87, respectively) were obtained with machine B. The results of the study reported here suggest machine B may be an effective blood pressure monitoring device in anesthetized dogs.  相似文献   

4.
ObjectiveTo assess accuracy of noninvasive blood pressure (NIBP) measured by oscillometric device Sentinel compared to invasive blood pressure (IBP) in anaesthetized horses undergoing surgery. To assess if differences between the NIBP measured by the Sentinel and IBP are associated with recumbency, cuff placement, weight of the horse or acepromazine premedication and to describe usefulness of the Sentinel.Study designProspective study examining replicates of simultaneous NIBP and IBP measurements.AnimalsTwenty-nine horses.MethodsInvasive blood pressure was measured via a catheter in the facial artery, transverse facial artery or metatarsal artery. NIBP was measured using appropriate size cuffs placed on one of two metacarpal or metatarsal bones or the tail in random order. With both techniques systolic (SAP), mean (MAP), and diastolic (DAP) arterial blood pressures and heart rates (HR) were recorded. A mixed effects model compared the IBP to the NIBP values and assessed potential effects of catheter placement, localisation of the cuffs in combination with recumbency, weight of the horse or acepromazine premedication.ResultsNoninvasive blood pressure yielded higher measurements than IBP. Agreement varied with recumbency and cuff position. Estimated mean differences between the two methods decreased from SAP (lateral recumbency: range -5.3 to -56.0 mmHg; dorsal recumbency: range 0.8 to -20.7 mmHg), to MAP (lateral recumbency: range -1.8 to -19.0 mmHg; dorsal recumbency: range 13.9 to -16.4 mmHg) to DAP (lateral recumbency: range 0.5 to -6.6 mmHg; dorsal recumbency: range 21.0 to -15.5 mmHg). NIBP measurement was approximately two times more variable than IBP measurement. No significant difference between IBP and NIBP due to horse's weight or acepromazine premedication was found. In 227 of 1047 (21.7%) measurements the Sentinel did not deliver a result.Conclusion and clinical relevanceAccording to the high variability of NIBP compared to IBP, NIBP measurements as measured by the Sentinel in the manner described here are not considered as an appropriate alternative to IBP to measure blood pressure in anaesthetized horses.  相似文献   

5.
Arterial blood pressure measurements were obtained from 158 healthy Irish wolfhounds using the oscillometric technique to establish reference values for the breed. In contrast to other sight hounds, Irish wolfhounds have low arterial blood pressure. Mean systolic pressure for the group was 116.0 mm Hg. Mean diastolic pressure was 69.2 mm Hg, and the mean value for mean arterial pressure was 87.8 mm Hg. Blood pressure measurements were higher in older wolfhounds than in young dogs. There was no difference between systolic and mean arterial blood pressures in lateral recumbency compared to standing position. However, diastolic pressure was slightly lower when standing. Calm dogs had lower pressure than anxious wolfhounds. There was a significant interaction between the effects of age, gender, and mood on systolic, diastolic, and mean arterial blood pressure values.  相似文献   

6.
ObjectivesThis study aimed to evaluate the effect of 8 hemodynamic conditions on blood pressure measurements taken from the carotid, femoral and dorsal pedal arteries of dogs.AnimalsSix healthy dogs.MethodsDuring isoflurane anesthesia, catheters were introduced into the carotid, femoral and dorsal pedal arteries of dogs to allow simultaneous monitoring of direct blood pressure in each artery. The dogs were submitted to 8 hemodynamic conditions induced by combining changes in heart rate (bradycardia, normocardia, tachycardia) with changes in blood pressure (hypotension, normotension, hypertension). Values obtained from each arterial catheter were compared and agreement between central (carotid) and peripheral (femoral and dorsal pedal) values were analyzed by the Bland–Altman method.ResultsDuring hypotensive conditions, systolic arterial pressure (SAP) was lower in the femoral and dorsal pedal arteries compared to the carotid artery whereas during normotensive and hypertensive conditions, SAP was higher in peripheral arteries. During hypotensive states, increases in heart rate resulted in greater bias between central and peripheral SAP whereas during normotensive states, the bias decreased as heart rate increased. Mean and diastolic arterial pressures were lower in the femoral and dorsal pedal arteries than in the carotid artery during most hemodynamic conditions.ConclusionsIn healthy anesthetized dogs, invasive blood pressure measurements in peripheral arteries may differ significantly from measurements in a central artery. The greatest differences were observed in SAP and the magnitude of differences between central and peripheral blood pressure measurements varied according to the dog's hemodynamic condition.  相似文献   

7.
ObjectiveTo compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks.Study designProspective, randomized, blinded study.AnimalsSix, sex unknown, adult red-tailed hawks.MethodsBirds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20–30% of circumference), cuff 2 (30–40%), and cuff 3 (40–50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland–Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals).ResultsThe IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (?9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds.Conclusions and clinical relevanceIndirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.  相似文献   

8.
Blood pressure (BP) measurements obtained using 3 indirect BP measuring instruments, a Doppler ultrasonic flowmeter, an oscillometric device, and a photoplethysmograph, were compared with direct arterial pressure measurements in 11 anesthetized cats. The standard deviation of the differences (SOD) between direct and indirect pressure measurements were not significantly different from each other ( P <.01), and ranged from 10.82 to 24.32 mm Hg. The high SDD values indicate that indirect BP estimates obtained with all these devices must be interpreted cautiously in individual patients. The mean errors (calculated as the sum of the differences between direct and indirect pressure measurements divided by the number of observations) of the 3 indirect devices were significantly different for systolic (SAP), diastolic (DAP), and mean (MAP) arterial pressures ( P <.05). The Doppler and photoplethysmographic devices had the highest overall accuracy, as indicated by mean error values of less than 10 mm Hg. Correlation coefficients varied from .88 to .96 for the Doppler flowmeter, and from .85 to .94 for the photoplethysmograph; for both devices, the regression line slopes were close to unity. The Doppler flowmeter detected a pulse under all experimental conditions. The photoplethysmograph was also efficient in obtaining BP measurements, obtaining over 90% of SAP, DAP, and MAP readings attempted. The oscillometric device was the least accurate, with mean error values varying from 10 to 22 mm Hg. Correlation coefficients were high (.90 to .94) for this device, but the slopes of the regression lines were 0.7 to 0.8, indicating a trend for increased error at higher BP. The oscillometric device tended to underestimate BP by increasing amounts as the BP increased. The oscillometric device was the least efficient device for obtaining BP measurements ( P <.01).  相似文献   

9.
Objective – To determine the difference between colloid osmotic pressure (COP) values determined from plasma versus those determined from whole blood. Design – Prospective observational study. Settings – University veterinary teaching hospital. Animals – Fifty‐three healthy dogs. Interventions – None. Measurements and Main Results – Whole blood and plasma COP, CBC, plasma biochemistry. In all dogs, plasma COP values were significantly lower (P=0.02) than whole blood COP, with a mean of difference of 0.5 mm Hg. The mean and median whole blood COP was 21.75 and 21.4 mm Hg, respectively, with a range of 17.9–27.1 mm Hg. The mean and median plasma COP was 21.2 and 20.9 mm Hg with a range of 16.7–28.9 mm Hg. Conclusions – While significant difference exists between plasma and whole blood COP, the individual values are within expected reference intervals for dogs (21–25 mm Hg). Using either sample appears to provide the same information in clinically healthy dog; however, it is recommended that clinicians utilize the same sample type for comparison in an individual patient.  相似文献   

10.
ObjectiveTo determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia.Study designExperimental study.AnimalsSeven healthy warmblood horses, aged 3–11 years, weighing 470–565 kg.MethodsMeasurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg−1 minute−1) over ten minutes followed by norepinephrine (0.1 mg kg−1 IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg−1 IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgResultsA total of 245 paired measurements of systolic (SAP), mean (MAP) and diastolic (DAP) pressures were obtained. The HDO device underestimated blood pressure at hypertensive and normotensive levels and overestimated blood pressure at hypotensive levels. Best agreement was obtained for SAP and MAP within normotensive limits. At normotension, bias ± standard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing.Conclusion and clinical relevanceGood agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable.  相似文献   

11.
ObjectiveTo assess the agreement between an oscillometric device and invasive blood pressure (IBP) measurements in anesthetized healthy adult guinea pigs.Study designProspective experimental study.AnimalsA total of eight adult Hartley guinea pigs.MethodsAll animals were anesthetized; a carotid artery was surgically exposed and catheterized for IBP measurements. A size 1 cuff placed on the right thoracic limb was connected to an oscillometric device for noninvasive blood pressure (NIBP) assessment. Concurrent pairs of systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressures were recorded simultaneously with both methods every 3 minutes for 30 minutes. Agreement between IBP and NIBP measurements was determined using the Bland–Altman method, considering the recommended standards for the validation of NIBP measurement devices proposed by the American College of Veterinary Internal Medicine (ACVIM).ResultsThe bias and the 95% limits of agreement were: –14 (–31 to 3) mmHg, –2 (–14 to 10) mmHg and –1 (–13 to 11) mmHg for SAP, DAP and MAP, respectively.Conclusions and clinical relevanceThe oscillometric device used in this study to measure NIBP did not meet ACVIM criteria for validation. It showed good agreement for DAP and MAP but not for SAP measurements. Considering the small size of these animals and the resulting difficulty in performing percutaneous arterial catheterization, this device might be a useful tool to assess MAP and DAP during anesthetic procedures in adult guinea pigs.  相似文献   

12.
Objective This study was conducted to evaluate the performance of a new veterinary oscillometric noninvasive blood pressure (NIBP) monitor in anesthetized dogs. Study design Assessment was made to determine how closely indirect measurements were associated with direct measurements, and if there were statistically significant differences between the measurements by site. Animals Six mongrel dogs weighing 27.8 ± 2.9 kg. Methods Dogs were anesthetized with thiopental and maintained with isoflurane, which was delivered with controlled ventilation. Direct pressure measurements were obtained via a percutaneously placed arterial catheter. A range of systolic arterial pressures (SAP) were achieved by changing the isoflurane concentrations. Sites of cuff placement for indirect measurements were identified as metacarpus, metatarsus, and anterior tibial. Results At pressures below 80 mm Hg, indirect systolic measurements averaged 4 ± 3 mm Hg, higher than the direct values. At normal and high levels, indirect systolic measurements underestimated direct values by 18 ± 6 and 23 ± 6 mm Hg, respectively. Diastolic and mean pressure measurements followed the same trend, with indirect values being lower than the direct arterial pressures. Systolic, diastolic and mean arterial pressure measurements differed by cuff‐placement site. Conclusions When analyzed by site and level, indirect systolic and mean arterial blood pressures during hypotension were essentially the same as direct pressures. However, at pressures within the normal or high range, indirect measurements underestimated the direct pressures. Clinical relevance Noninvasive blood pressure measurements with a new oscillometric monitor provided an excellent means of detecting arterial hypotension in anesthetized dogs. The metatarsal site for cuff placement was slightly better than the metacarpal or anterior tibial site, considering that the regression line was closest to complete equality between the indirect and direct measurements for SAP.  相似文献   

13.
The precision and accuracy of an indirect oscillometric blood pressure measurement technique (Dinamap 8100) was assessed in 11 anesthetized Beagle dogs weighing 8 to 11.5 kg. Direct blood pressure measurements were made by catheterization of the lingual artery, and simultaneous indirect measurements were determined by placing a cuff over the median artery (midradial area). Blood pressure measurements at 2 different planes of anesthesia (light and deep) were recorded in triplicate. At a light plane of anesthesia, the Dinamap 8100 underestimated diastolic and mean arterial pressure, and at a deep anesthetic plane overestimated systolic pressure. The indirect technique had good repeatability of systolic pressures. Regression analysis for the 2 techniques showed excellent correlation (r = 0.93). The results indicate that the indirect oscillometric blood pressure measurement technique provides a good estimate of systolic, diastolic, and mean arterial pressure in dogs weighing 8-11.5 kg.  相似文献   

14.
Objective: To determine the arterial blood pressure at presentation in male cats with acute urethral obstruction, and to determine whether there was any correlation between these measurements and concurrent metabolic abnormalities. Design: Prospective, single cohort, observational study. Setting: Private, small animal, after‐hours emergency clinic. Animals: Twenty‐eight client‐owned male cats with acute urethral obstruction and no other known coexisting disease. Interventions: Indirect oscillometric blood pressure measurements obtained before blood sampling and treatment. Measurements and main results: Mean arterial blood pressure (MAP) measurements, physical examination parameters, serum blood urea nitrogen (BUN), creatinine, potassium, phosphorus, total calcium and magnesium concentration, venous pH, lead II electrocardiogram, and urine volume in bladder were evaluated. No cats were hypotensive at presentation; 71% (20/28) were normotensive (median MAP=100 mmHg, range 93–140 mmHg); and 29% (8/28) were hypertensive (median MAP=153 mmHg, range 145–176 mmHg). Compared with hypertensive cats, normotensive cats had significantly lower heart rates (P=0.0201) and lower calcium (P=0.0152). For all 28 cats, MAP correlated with serum potassium and total calcium (P=0.0033). Conclusions: Though potassium and total calcium were inversely and directly correlated respectively with blood pressure in cats with urethral obstruction, none of the cats were hypotensive on presentation. Normotension on admission does not support the absence of biochemical and physical abnormalities in obstructed cats.  相似文献   

15.
In a series of 3 studies, indirect blood pressure measurements were obtained to define normal variance, identify hypertension, and estimate the prevalence of hypertension in apparently healthy dogs. In part 1, we measured values in 5 clinically normal dogs twice weekly for 5 weeks in a home setting. Mean +/- SD systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) was 150 +/- 16 and 86 +/- 13 mm of Hg, respectively. The DAP significantly (P less than 0.01) decreased with repeated measurements over the 5-week period. In part 2, we assessed the variation between blood pressures measured in a clinic vs those measured in the home. Within a 2-week period, measurements were obtained from 10 clinically normal dogs in a private veterinary clinic and again in their home. Significant differences were not observed between clinic and home measurements of SAP and DAP; however, heart rate was significantly (P less than 0.05) higher in the clinic. In part 3, SD about the SAP and DAP mean values were determined in 102 clinically normal dogs. Canine hypertensive status was determined, using statistical methods and data from 102 clinically normal dogs. Values of SAP greater than 202 mm of Hg and DAP greater than 116 mm of Hg were determined to be 2 SD beyond the mean and, therefore, were interpreted to be hypertensive. Approximately 10% of the 102 apparently healthy dogs measured in this study were considered hypertensive on the basis of these criteria. In addition, a border zone of suspected hypertension was estimated, using the mean + 1.282 SD. The SAP border zone was between 183 and 202 mm of Hg, whereas the DAP border zone was between 102 and 113 mm of Hg. Of the 102 dogs, 12 had values within these zones of suspected hypertension.  相似文献   

16.
Objective —To determine the accuracy of three indirect blood pressure monitoring techniques (oscillometric technique [OS], Doppler [DOP], and optical plethysmography [OP] [blood pressure determined with a pulse oximeter waveform]) when compared with direct arterial pressure measurement in cats. Study Design —Prospective study. Animal Population —Eight healthy (five female, three male), domestic short-hair cats, weighing 3.5 ± 0.8 kg Methods —Cats were anesthetized with isoflurane. The inspired concentration of isoflurane was adjusted to produce mild hypotension (80 to 100 mm Hg direct systolic), moderate hypotension (60 to 80 mm Hg direct systolic), and severe hypotension (<60 mm Hg direct systolic). Indirect pressure measurements were obtained from the thoracic limb and compared with concurrent direct measurement using regression analysis and a modification of Bland and Altman's technique. Results —All three techniques underestimated systolic pressure. OS produced the best prediction of systolic pressure with a bias ± precision of -15.9 ± 8.1 mm Hg. DOP and OP were relatively inaccurate with a bias ± precision of -25 ± 7.4 mm Hg and -25 ± 7.5 mm Hg. All three techniques correlated well with direct pressure with r values of 0.81, 0.88, and 0.88 for OS, DOP, and OP. DOP and OP provided an accurate prediction of direct mean arterial pressure with a bias ± precision of -0.8 ± 6 mm Hg and 0.6 ± 5.5 mm Hg. Correlation was good between DOP and mean arterial pressure with r = 0.89. Correlation was also good between OP and mean arterial pressure with r = 0.90. Conclusions —OS provided the most accurate prediction of direct systolic pressure. DOP and OP provided a good prediction of mean arterial pressure in the cat. Clinical Relevance —All three of these techniques are useful for detecting trends. Direct monitoring of blood pressure should be considered if accurate blood pressure measurement is required.  相似文献   

17.
OBJECTIVE: To compare the performance of the Surgivet Non-Invasive Blood Pressure (NIBP) monitor V60046 with an invasive blood pressure (IBP) technique in anaesthetized dogs. STUDY DESIGN: A prospective study. ANIMALS: Thirty-four dogs, anaesthetized for a variety of procedures. METHODS: Various anaesthetic protocols were used. Invasive blood pressure measurement was made using a catheter in the femoral or the pedal artery. A cuff was placed on the contralateral limb to allow non invasive measurements. Recordings of arterial blood pressures (ABPs) were taken at simultaneous times for a range of pressures. For analysis, three pressure levels were determined: high [systolic blood pressure (SAP) > 121 mmHg], normal (91 mmHg < SAP < 120 mmHg) and low (SAP < 90 mmHg). Comparisons between invasive and non invasive measurements were made using Bland-Altmann analysis. RESULTS: The NIBP monitor consistently underestimated blood pressure at all levels. The lowest biases and greatest precision were obtained at low and normal pressure levels for SAP and mean arterial pressure (MAP). At low blood pressure levels, the biases +/- 95% confidence interval (CI) were 1.9 +/- 2.96 mmHg (SAP), 8.3 +/- 2.41 mmHg diastolic arterial pressure (DAP) and 3.5 +/- 2.09 mmHg (MAP). At normal blood pressure levels, biases and CI were: 1.2 +/- 2.13 mmHg (SAP), 5.2 +/- 2.32 mmHg (DAP) and 2.1 +/- 1.54 mmHg (MAP). At high blood pressure levels, the biases and CI were 22.7 +/- 5.85 mmHg (SAP), 5.5 +/- 3.13 mmHg (DAP) and 9.4 +/- 3.52 mmHg (MAP). In 90.6% of cases of hypotension (MAP < 70 mmHg), the low blood pressure was correctly diagnosed by the Surgivet. CONCLUSIONS: Measurement of blood pressure with the indirect monitor allowed detection of hypotension using either SAP or MAP. The most accurate readings were determined for MAP at hypotensive and normal levels. The monitor lacked accuracy at high pressures. CLINICAL RELEVANCE: When severe challenges to the cardiovascular system are anticipated, an invasive method of recording ABP is preferable. For routine usage, the Surgivet monitor provided a reliable and safe method of NIBP monitoring in dogs, thereby contributing to the safety of anaesthesia by providing accurate information about the circulation.  相似文献   

18.
Objective To use the American College of Veterinary Internal Medicine (ACVIM) validation criteria to evaluate the performance of high definition oscillometric (HDO) and Doppler blood pressure measurement techniques against invasive blood pressure measurements in anaesthetized dogs. Study design Prospective clinical study. Animals Twenty client‐owned dogs. Materials and Methods Invasive blood pressure was measured using a catheter inserted into a pedal artery and an electronic transducer. The sites of cuff placement for the HDO measurements were the mid antebrachium or the proximal tail and, for the Doppler technique, the distal tibia. Agreement between invasive and non‐invasive blood pressure measurements was estimated by the Bland–Altman method. Results Only 10% and 34% of Doppler measurements were within 10 and 20 mmHg of invasive blood pressure values, respectively. The Doppler device failed to meet the ACVIM validation criteria for blood pressure measurement devices. The best agreement between HDO and invasive blood pressure measurement technique was observed for mean arterial blood pressure (MAP); 67% and 95% of readings were within 10 and 20 mmHg of invasive blood pressure values respectively. In addition, 52% and 87% of diastolic arterial blood pressure (DAP) measurements were within 10 and 20 mmHg of invasive readings. High definition oscillometric readings did not meet ACVIM recommended limits for SAP. Conclusion and clinical relevance The Doppler technique overestimated and the HDO device showed limited agreement with invasive blood pressure measurement in anaesthetized dogs. High definition oscillometry met most of the ACVIM requirements for MAP and DAP while the Doppler technique did not.  相似文献   

19.
OBJECTIVE: To determine whether there was an association between hypertensive retinopathy and high systolic, diastolic, and mean arterial blood pressures in cats. ANIMALS: 181 cats. PROCEDURE: Systolic, diastolic, and mean arterial blood pressures were measured by use of a noninvasive oscillometric technique. The range of blood pressure measurements in healthy cats from various age groups was determined. Associations among systolic, diastolic, and mean arterial blood pressure; hypertensive retinopathy; hyperthyroidism; left ventricular cardiac hypertrophy; chronic renal failure; and serum biochemical abnormalities were determined. RESULTS: All blood pressure measurements increased with age in healthy cats. The frequency of hypertensive retinopathy also increased with age and with blood pressure, and hypertensive retinopathy was particularly found in cats with systolic blood pressures > 168 mm Hg. There was an increased risk for hypertensive retinopathy in cats that were female, > 10 years old, and neutered. The risk of chronic renal failure also increased as blood pressure, particularly systolic blood pressure, increased. CONCLUSIONS AND CLINICAL RELEVANCE: Hypertensive retinopathy was common in cats > or = 10 years of age and was associated with systolic blood pressures > 168 mm Hg when measured by the noninvasive oscillometric technique.  相似文献   

20.
OBJECTIVES: To obtain reference arterial blood pressure values from Kangal dogs, a local giant breed found in Turkey. METHODS: Arterial blood pressure measurements were obtained from 48 healthy Kangal dogs using oscillometric and Doppler techniques. The ages of the dogs ranged from two to 96 months, with a mean (sd) age of 36 (16) months. RESULTS: The effect of age on systolic, diastolic and mean arterial pressures determined by the oscillometric technique and on systolic pressure determined by the Doppler technique was significant (P<0.001). Blood pressure was found to be higher in mature dogs compared with that in immature dogs. The effect of sex and the interaction between age and sex were not significant (P>0.05). There was a direct relationship between age and oscillometric systolic, diastolic and mean arterial pressures and Doppler systolic arterial blood pressure both in the whole group and the immature group (P<0.05). Correlation between age and systolic arterial blood pressure measured either by oscillometric or Doppler techniques was not significant in the mature group. CLINICAL SIGNIFICANCE: The Kangal dog is bred in various countries including Turkey. It is known that giant breed dogs, such as the Kangal dog, are predisposed to cardiovascular disease. Canine arterial blood pressure values are highly breed and age dependent, so a reference value for any other breed is inappropriate for Kangal dogs. Therefore, it is important to measure arterial blood pressure of Kangal dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号