OBJECTIVE: To determine arterial blood pressure in client-owned dogs, using direct arterial puncture, oscillometry, and Doppler ultrasonography in a clinical setting. DESIGN: Prospective study. ANIMALS: 8 clinically normal client-owned dogs. PROCEDURE: Blood pressures of nonsedated dogs were measured simultaneously, using each of the 3 methods. Mean values obtained were compared with published mean values. Ability of noninvasive methods (Doppler ultrasonography and oscillometry) to accurately predict results of the invasive method, and relationships between blood pressure and age, body weight, and degree of patient anxiety were determined. RESULTS: Calculated ranges of values (mean +/- 2 SD) determined by direct arterial puncture were: systolic pressure, 114 to 194 mm Hg; diastolic pressure, 66 to 102 mm Hg; and mean pressure, 85 to 129 mm Hg. Ranges determined by use of oscillometry were: systolic, 110 to 190 mm Hg; diastolic, 35 to 107 mm Hg; and mean, 78 to 138 mm Hg. Ultrasonographic and oscillometric values did not accurately predict direct values, but mean values of systolic and mean pressures were similar among methods. Relationships were not detected between age or body weight and blood pressure. Significant differences in blood pressure were not detected between anxious and nonanxious dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Mean values of systolic, diastolic, and mean arterial blood pressure measured in nonsedated client-owned dogs, using invasive and noninvasive methods in a clinical setting, are comparable with those determined for acclimatized, trained, or sedated dogs. However, results of noninvasive methods may not accurately reflect direct values.  相似文献   

2.
Objective This study was conducted to evaluate the performance of a new veterinary oscillometric noninvasive blood pressure (NIBP) monitor in anesthetized dogs. Study design Assessment was made to determine how closely indirect measurements were associated with direct measurements, and if there were statistically significant differences between the measurements by site. Animals Six mongrel dogs weighing 27.8 ± 2.9 kg. Methods Dogs were anesthetized with thiopental and maintained with isoflurane, which was delivered with controlled ventilation. Direct pressure measurements were obtained via a percutaneously placed arterial catheter. A range of systolic arterial pressures (SAP) were achieved by changing the isoflurane concentrations. Sites of cuff placement for indirect measurements were identified as metacarpus, metatarsus, and anterior tibial. Results At pressures below 80 mm Hg, indirect systolic measurements averaged 4 ± 3 mm Hg, higher than the direct values. At normal and high levels, indirect systolic measurements underestimated direct values by 18 ± 6 and 23 ± 6 mm Hg, respectively. Diastolic and mean pressure measurements followed the same trend, with indirect values being lower than the direct arterial pressures. Systolic, diastolic and mean arterial pressure measurements differed by cuff‐placement site. Conclusions When analyzed by site and level, indirect systolic and mean arterial blood pressures during hypotension were essentially the same as direct pressures. However, at pressures within the normal or high range, indirect measurements underestimated the direct pressures. Clinical relevance Noninvasive blood pressure measurements with a new oscillometric monitor provided an excellent means of detecting arterial hypotension in anesthetized dogs. The metatarsal site for cuff placement was slightly better than the metacarpal or anterior tibial site, considering that the regression line was closest to complete equality between the indirect and direct measurements for SAP.  相似文献   

3.
Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.  相似文献   

4.
Systemic arterial blood pressures were measured in 30 dogs with acute babesiosis, 10 each with mild uncomplicated, severe uncomplicated and complicated disease. Ten healthy dogs were used as controls. Hypotension was defined as more than 3 standard deviations below the control mean. Normal mean pressures (+/-SD) were: systolic arterial pressure 151 (+/-11) mm Hg, diastolic arterial pressure 89 (+/-8) mm Hg and mean arterial pressure 107 (+/-10) mm Hg. Hypotension was the most frequent abnormality, and increased strikingly in incidence as disease severity increased, with 5/10 dogs in the complicated group being hypotensive for systolic, diastolic and mean arterial pressures, compared with 2/10 in the severe uncomplicated group and 0/10 in the mild uncomplicated group. Systolic, diastolic and mean arterial pressures in the complicated group and severe uncomplicated group, and systolic pressure in the mild uncomplicated group, were significantly lower than in the controls. There were no significant relationships between arterial pressures and age, pulse rate, respiratory rate, temperature, mucous membrane colour or haematocrit. There was a significant negative correlation between arterial pressures and white cell and immature neutrophil counts. Arterial pressures differed significantly between dogs that were clinically collapsed and those that were not, but not between survivors and non-survivors. Pulse pressure (systolic-diastolic) was low in 7/10 complicated, 1/10 mild uncomplicated, and 1/10 severe uncomplicated cases, and differed significantly between the complicated and control groups. The high incidence of hypotension in clinically severe babesiosis has important implications for therapy.  相似文献   

5.
In a series of 3 studies, indirect blood pressure measurements were obtained to define normal variance, identify hypertension, and estimate the prevalence of hypertension in apparently healthy dogs. In part 1, we measured values in 5 clinically normal dogs twice weekly for 5 weeks in a home setting. Mean +/- SD systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) was 150 +/- 16 and 86 +/- 13 mm of Hg, respectively. The DAP significantly (P less than 0.01) decreased with repeated measurements over the 5-week period. In part 2, we assessed the variation between blood pressures measured in a clinic vs those measured in the home. Within a 2-week period, measurements were obtained from 10 clinically normal dogs in a private veterinary clinic and again in their home. Significant differences were not observed between clinic and home measurements of SAP and DAP; however, heart rate was significantly (P less than 0.05) higher in the clinic. In part 3, SD about the SAP and DAP mean values were determined in 102 clinically normal dogs. Canine hypertensive status was determined, using statistical methods and data from 102 clinically normal dogs. Values of SAP greater than 202 mm of Hg and DAP greater than 116 mm of Hg were determined to be 2 SD beyond the mean and, therefore, were interpreted to be hypertensive. Approximately 10% of the 102 apparently healthy dogs measured in this study were considered hypertensive on the basis of these criteria. In addition, a border zone of suspected hypertension was estimated, using the mean + 1.282 SD. The SAP border zone was between 183 and 202 mm of Hg, whereas the DAP border zone was between 102 and 113 mm of Hg. Of the 102 dogs, 12 had values within these zones of suspected hypertension.  相似文献   

6.
Adaptation of human oscillometric blood pressure monitors for use in dogs   总被引:2,自引:0,他引:2  
Two digital oscillometric human blood pressure measuring devices were modified and evaluated as blood pressure monitors in 12 healthy anesthetized dogs. Direct arterial pressures were measured via cannulation of the dorsal pedal artery and were correlated with indirect measurements through an inflatable cuff placed over the dorsal pedal artery below the hock joint of the contralateral limb. Direct and indirect measurements were compared for systolic, diastolic, and calculated mean arterial pressures. Blood pressure ranges between 215/145 mm of Hg and 65/30 mm of Hg were obtained, using combinations of halothane, phenylephrine, calcium, and IV administered fluids. Machine A was found to be insufficient for clinical application, on the basis of correlation coefficients between direct and indirect pressures of 0.78, 0.65, and 0.74 for systolic, diastolic, and mean arterial pressures, respectively. Higher correlation coefficients between direct and indirect pressures (0.77, 0.87, and 0.87, respectively) were obtained with machine B. The results of the study reported here suggest machine B may be an effective blood pressure monitoring device in anesthetized dogs.  相似文献   

7.
OBJECTIVE: To determine whether there was an association between hypertensive retinopathy and high systolic, diastolic, and mean arterial blood pressures in cats. ANIMALS: 181 cats. PROCEDURE: Systolic, diastolic, and mean arterial blood pressures were measured by use of a noninvasive oscillometric technique. The range of blood pressure measurements in healthy cats from various age groups was determined. Associations among systolic, diastolic, and mean arterial blood pressure; hypertensive retinopathy; hyperthyroidism; left ventricular cardiac hypertrophy; chronic renal failure; and serum biochemical abnormalities were determined. RESULTS: All blood pressure measurements increased with age in healthy cats. The frequency of hypertensive retinopathy also increased with age and with blood pressure, and hypertensive retinopathy was particularly found in cats with systolic blood pressures > 168 mm Hg. There was an increased risk for hypertensive retinopathy in cats that were female, > 10 years old, and neutered. The risk of chronic renal failure also increased as blood pressure, particularly systolic blood pressure, increased. CONCLUSIONS AND CLINICAL RELEVANCE: Hypertensive retinopathy was common in cats > or = 10 years of age and was associated with systolic blood pressures > 168 mm Hg when measured by the noninvasive oscillometric technique.  相似文献   

8.
OBJECTIVES: To obtain reference arterial blood pressure values from Kangal dogs, a local giant breed found in Turkey. METHODS: Arterial blood pressure measurements were obtained from 48 healthy Kangal dogs using oscillometric and Doppler techniques. The ages of the dogs ranged from two to 96 months, with a mean (sd) age of 36 (16) months. RESULTS: The effect of age on systolic, diastolic and mean arterial pressures determined by the oscillometric technique and on systolic pressure determined by the Doppler technique was significant (P<0.001). Blood pressure was found to be higher in mature dogs compared with that in immature dogs. The effect of sex and the interaction between age and sex were not significant (P>0.05). There was a direct relationship between age and oscillometric systolic, diastolic and mean arterial pressures and Doppler systolic arterial blood pressure both in the whole group and the immature group (P<0.05). Correlation between age and systolic arterial blood pressure measured either by oscillometric or Doppler techniques was not significant in the mature group. CLINICAL SIGNIFICANCE: The Kangal dog is bred in various countries including Turkey. It is known that giant breed dogs, such as the Kangal dog, are predisposed to cardiovascular disease. Canine arterial blood pressure values are highly breed and age dependent, so a reference value for any other breed is inappropriate for Kangal dogs. Therefore, it is important to measure arterial blood pressure of Kangal dogs.  相似文献   

9.
The objective of this study was to evaluate the use of desflurane after induction of anesthesia with propofol in dogs sedated with romifidine or medetomidine. Each of 8 healthy dogs received intravenously, in random order, 3 preanesthetic protocols: romifidine, 40 microg/kg of body weight (BW) (R40); romifidine, 80 microg/kg BW (R80); and medetomidine, 10 microg/kg BW (MED). Cardiovascular and respiratory variables were recorded during the procedure. Time to extubation, time to sternal recumbency, and time to standing were also recorded. Heart rate and respiratory rate decreased significantly during sedation from baseline values, but there were no differences between the means for the 3 preanesthetic protocols. Mean values for heart rate, mean arterial blood pressure, systolic arterial pressure, diastolic arterial pressure, respiratory rate, tidal volume, arterial oxygen saturation, end-tidal CO2 level, pH, and arterial blood gas values during anesthesia were similar for the 3 protocols. The mean end-tidal desflurane concentration was significantly lower with the R80 protocol than with the R40 protocol. The mean time to extubation was significantly shorter with the R40 protocol than with the R80 and MED protocols.  相似文献   

10.
OBJECTIVE: To determine effects of atracurium on intraocular pressure (IOP), eye position, and arterial blood pressure in eucapnic and hypocapnic dogs anesthetized with isoflurane. ANIMALS: 16 dogs. PROCEDURE: Ventilation during anesthesia was controlled to maintain Paco2 at 38 to 44 mm Hg in group- I dogs (n = 8) and 26 to 32 mm Hg in group-II dogs (8). Baseline measurements for IOP, systolic, diastolic, and mean arterial blood pressure, central venous pressure (CVP), and heart rate (HR) were recorded. Responses to peroneal nerve stimulation were monitored by use of a force-displacement transducer. Atracurium (0.2 mg/kg) was administered i.v. and measurements were repeated at 1, 2, 3, and 5 minutes and at 5-minute intervals thereafter for 60 minutes. RESULTS: Atracurium did not affect IOP, HR, or CVP Group II had higher CVP than group I, but IOP was not different. There was no immediate effect of atracurium on arterial blood pressure. Arterial blood pressure increased gradually over time in both groups. Thirty seconds after administration of atracurium, the eye rotated from a ventromedial position to a central position and remained centrally positioned until 100% recovery of a train-of-four twitch response. The time to 100% recovery was 53.1 +/- 5.3 minutes for group I and 46.3 +/- 9.2 minutes for group II. CONCLUSIONS AND CLINICAL RELEVANCE: Atracurium did not affect IOP or arterial blood pressure in isoflurane-anesthetized dogs. Hyperventilation did not affect IOP or the duration of effect of atracurium.  相似文献   

11.
Objective – To determine the accuracy and precision of an oscillometric noninvasive blood pressure device as a predictor of invasive direct blood pressure in healthy anesthetized hypotensive and normotensive dogs. Design – Prospective observational study. Setting – University teaching hospital. Animals – Eight crossbred adult dogs. Interventions – Anesthesia was induced with propofol and maintained with isoflurane. A catheter was placed in the dorsal pedal artery to record systolic, mean, and diastolic arterial blood pressures (aSAP, aMAP, and aDAP, respectively). The noninvasive blood pressure device cuff was placed around the contralateral front limb to record noninvasive systolic, mean, and diastolic blood pressure (nSAP, nMAP, and nDAP). Two states of blood pressure (BP) were studied: baseline state was established by keeping end‐tidal isoflurane concentration at 1.2±0.1%. The hypotensive state was achieved by maintaining the same isoflurane concentration while withdrawing approximately 40% of the animal's blood volume until aMAP was stable at approximately 40 mm Hg. At the end of the study, blood was returned to the animal and it was allowed to recover from anesthesia. Measurements and Main Results – Agreement between the direct and indirect BP measurements was determined by the Bland‐Altman method. The SAP and MAP but not DAP bias varied significantly between each BP state. Normotensive absolute biases (mean [SD]) for SAP, MAP, and DAP were ?14.7 mm Hg (15.5 mm Hg), ?16.4 mm Hg (12.1 mm Hg), and ?14.1 mm Hg (15.8 mm Hg), respectively. Absolute biases during the hypotensive state for SAP, MAP, and DAP were ?32 mm Hg (22.6 mm Hg), ?24.2 mm Hg (19.5 mm Hg), and ?16.8 mm Hg (17.2 mm Hg), respectively. Conclusion – The oscillometric device was not reliably predictive of intra‐arterial BP during hypotension associated with acute hemorrhage.  相似文献   

12.
CASE DESCRIPTION: A 5-year-old male German Shepherd Dog was evaluated because of a 5-month history of progressive lethargy, weight loss, and heart failure. CLINICAL FINDINGS: On physical examination, bounding femoral pulses and systolic and diastolic murmurs were detected. Echocardiography revealed severe aortic valve insufficiency (AVI) and a large vegetative lesion on the aortic valve consistent with aortic valve endocarditis. The AVI velocity profile half-time was 130 milliseconds; the calculated peak systolic pressure gradient across the aortic valve was 64 mm Hg. Left ventricular diameter during diastole was 63.6 mm (predicted range, 40.2 to 42 mm) and during systole was 42.9 mm (predicted range, 25.4 to 27 mm). Systolic, diastolic, and mean arterial blood pressures were 120, 43, and 65 mm Hg, respectively. TREATMENT AND OUTCOME: To palliate severe AVI, the descending aorta was occluded (duration, 16.75 minutes) and heterotopic implantation of a porcine bioprosthetic heart valve in that vessel was performed. After surgery, systolic, diastolic, and mean arterial blood pressures were 115, 30, and 61 mm Hg, respectively, in the forelimb and 110, 62, and 77 mm Hg, respectively, in the hind limb. Within 6 months, the AVI velocity profile half-time had increased to 210 milliseconds, indicating diminished severity of AVI. After 24 months, the dog was able to engage in vigorous exercise; no pulmonary edema had developed since surgery. CLINICAL RELEVANCE: Heterotopic bioprosthetic heart valve implantation into the descending aorta during brief aortic occlusion appears feasible in dogs and may provide substantial palliation for dogs with severe AVI.  相似文献   

13.
OBJECTIVE: To examine the agreement between direct arterial blood pressure measurements obtained from 2 arteries and indirect blood pressure measurements obtained with an oscillometric blood pressure monitor (OBPM) during normotension and phenylephrine-induced hypertension in dogs. ANIMALS: 16 male Beagles. PROCEDURES: In anesthetized dogs, arterial catheters were placed in the lingual and dorsal pedal arteries for measurement of arterial blood pressure. A blood pressure cuff was placed on either the dog's fore- or hind limb and connected to an OBPM. Systolic, diastolic, and mean arterial blood pressures (SAP, DAP, and MAP, respectively) were recorded from both arteries and the OBPM every 5 minutes for 30 minutes (baseline), during a 30-minute period in which dogs received a phenylephrine infusion IV to induce hypertension, and for 30 minutes after discontinuation of the infusion. Mean differences in blood pressure values and confidence intervals were calculated to compare the indirect and direct measurement techniques. RESULTS: In dogs, oscillometry underestimated SAP during normotension, and the difference between oscillometric and direct measurements increased during hypertension. Oscillometry underestimated DAP, but the difference between oscillometric and direct measurements decreased during hypertension. There was close agreement among techniques for MAP determinations. Biases between direct measurements and OPBM blood pressure values measured from dogs' forelimbs or hind limbs were not significantly different. CONCLUSIONS AND CLINICAL RELEVANCE: In normotensive dogs, oscillometric measurements of MAP and SAP agreed more closely with direct arterial pressure measurements than oscillometric estimates of DAP. Oscillometric measurement of MAP was accurate during both normotension and hypertension in dogs.  相似文献   

14.
Objective The purpose of this study was to determine the cardiovascular effects of sevoflurane in calves. Study design Prospective experimental study. Animals Six, healthy, 8–12‐week‐old Holstein calves weighing 80 ± 4.5 (mean ± SEM) kg were studied. Methods Anesthesia was induced by face‐mask administration of 7% sevoflurane in O2. Calves tracheae were intubated, placed in right lateral recumbency, and maintained with 3.7% end‐tidal concentration sevoflurane for 30 minutes to allow catheterization of the auricular artery and placement of a Swan‐Ganz thermodilution catheter into the pulmonary artery. After instrumentation, administration of sevoflurane was temporarily discontinued until mean arterial pressure was > 100 mm Hg. Baseline values were recorded and the vaporizer output increased to administer 3.7% end‐tidal sevoflurane concentration. Ventilation was controlled to maintain normocapnia. The following were recorded at 5, 10, 15, 30 and 45 minutes after collection of baseline data and expressed as the mean value (± SEM): direct systolic, diastolic, and mean arterial blood pressures; cardiac output; mean pulmonary arterial pressure; pulmonary arterial occlusion pressure, heart rate; and pulmonary arterial temperature. Cardiac index and systemic and pulmonary vascular resistance values were calculated using standard formulae. Arterial blood gases were analyzed at baseline, and at 15 and 45 minutes. Differences from baseline values were determined using one‐way analysis of variance for repeated measures with post‐hoc differences between mean values identified using Dunnet's test (p < 0.05). Results Mean time from beginning sevoflurane administration to intubation of the trachea was 224 ± 9 seconds. The mean end‐tidal sevoflurane concentration at baseline was 0.7 (± 0.11)%. Sevoflurane anesthesia was associated with decreased arterial blood pressure at all sampling times. Mean arterial blood pressure decreased from a baseline value of 112 ± 7 mm Hg to a minimum value of 88 ± 4 mm Hg at 5 minutes. Compared with baseline, arterial pH was decreased at 15 minutes. Pulmonary arterial blood temperature was decreased at 15, 30 and 45 minutes. Arterial CO2 tension increased from a baseline value of 43 ± 3 to 54 ± 4 mm Hg (5.7 ± 0.4 to 7.2 ± 0.3 kPa) at 15 minutes. Mean pulmonary arterial pressure was increased at 30 and 45 minutes. Pulmonary arterial occlusion pressure increased from a baseline value of 18 ± 2 to 23 ± 2 mm Hg at 45 minutes. There were no significant changes in other measured variables. All calves recovered from anesthesia uneventfully. Conclusion We conclude that sevoflurane for induction and maintenance of anesthesia was effective and reliable in these calves and that neither hypotension nor decreased cardiac output was a clinical concern. Clinical relevance Use of sevoflurane for mask induction and maintenance of anesthesia in young calves is a suitable alternative to injectable and other inhalant anesthetics.  相似文献   

15.
Intramedullary pressure in canine long bones   总被引:1,自引:0,他引:1  
Intramedullary pressure was measured bilaterally in 36 dogs: in the diaphysis and distal metaphysis of the femur, in the proximal metaphysis of the tibia and humerus, and in the diaphysis of the radius. Pressure measurements were repeated in 5 dogs, 14 days after the initial recordings. Mean (+/- SD) pressures in the femoral diaphysis and distal metaphysis were 27.6 (+/- 15.4) mm of Hg and 17.6 (+/- 10.5) mm of Hg, respectively. Mean (+/- SD) pressures in the tibial diaphysis and proximal metaphysis were 26.4 (+/- 13.0) mm of Hg and 17.9 (+/- 11.8) mm of Hg, respectively. Mean (+/- SD) pressures in the humeral diaphysis and proximal metaphysis were 26.2 (+/- 15.8) mm of Hg and 13.4 (+/- 7.7) mm of Hg, respectively. The mean (+/- SD) pressure in the radial diaphysis was 15.4 (+/- 18.9) mm of Hg. Metaphyseal pressure was significantly (P less than 0.05) lower than diaphyseal pressure. Repeated pressure measurements in 5 dogs did not vary significantly from initial values, suggesting that the wide range of pressure was real not artifactual.  相似文献   

16.
The cardiopulmonary effects of different levels of carbon dioxide insufflation (3, 5 and 2 mm Hg) under two-lung ventilation were studied in six sevoflurane (1.5 minimum alveolar concentration; MAC) anaesthetized dogs during left-sided thoracoscopy. An arterial catheter, Swan-Ganz catheter and multianaesthetic gas analyser were used to monitor the cardiopulmonary parameters during the experiment. Baseline data were obtained before intrathoracic pressure elevation and the measurements were repeated at intervals after left lung collapse induced by insufflation with carbon dioxide gas. The intrapleural pressure levels used were 3, 5 and 2 mm Hg. Arterial blood pressures, cardiac index, stroke index, left and right ventricular stroke work index, arterial haemoglobin saturation, arterial oxygen tension and systemic vascular resistance decreased significantly during hemithorax insufflation, whereas heart rate, right atrial pressure, mean, systolic and diastolic pulmonary arterial pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance and arterial carbon dioxide tension significantly increased during intrapleural pressure elevation. Although carbon dioxide insufflation into the left hemithorax with an intrapleural pressure of 2-5 mm Hg compromises cardiac functioning in 1.5 MAC sevoflurane anaesthetized dogs, it can be an efficacious adjunct for thoracoscopic procedures. Intrathoracic view was satisfactory with an intrapleural pressure of 2 mm Hg. Therefore, the intrathoracic pressure rise during thoracoscopy with two-lung ventilation should be kept as low as possible. Additional insufflation periods should be avoided, since a more rapid and more severe cardiopulmonary depression can occur.  相似文献   

17.
Out of 400 Irish wolfhounds cardiologically examined, echocardiographic measurements of 262 normal dogs were analyzed to obtain reference values for the breed. Based on regression analysis, several echocardiographic parameters showed significant linear correlation with body weight and with age, but coefficients of determination were low. Therefore, due to a high individual variability of echocardiographic measurements in adult Irish wolfhounds, the predictive value of body weight for echocardiographic measurements was clinically not relevant. Sex had no influence on echocardiographic values. For the estimation of myocardial function, end-systolic volume index (ESVI) (mean, 29.0 ml/m2 +/- standard deviation [SD], 5.9 ml/m2) was determined for the group of 262 normal dogs.  相似文献   

18.
OBJECTIVE: To determine accuracy of an oscillometric blood pressure monitor used over a wide range of pressures in anesthetized cats. DESIGN: Prospective study. ANIMALS: 6 healthy cats. PROCEDURE: 4 female cats and 2 male cats that weighed 2.7 to 4.5 kg (5.9 to 9.9 lb) and were 2 to 8 years old were anesthetized. Blood pressure was measured directly with an arterial catheter placed in the right femoral artery and indirectly from the left antebrachium by use of an oscillometric monitor. A series of diastolic arterial pressure (DAP), mean arterial pressure (MAP), and systolic arterial pressure (SAP) measurements were obtained during hypotension, normotension, and hypertension. Values obtained indirectly and directly were compared. RESULTS: The oscillometric monitor was accurate for DAP and MAP throughout the entire pressure range and met the standards of the Association for the Advancement of Medical Instrumentation (mean +/- SD difference from values obtained directly, < or = 5 +/- 8 mm Hg). The SAP was increasingly underestimated with increasing overall pressure; mean differences from direct measurements were -5.2, -12.1, and -17.7 mm Hg during hypo-, normo-, and hypertension, respectively. Standard deviations for SAP were all < or = 8 mm Hg. The monitor gave readings during all attempts. The direct blood pressure recording system appeared to perform well with neither under- nor overdamping. CONCLUSIONS AND CLINICAL RELEVANCE: Except for a minor underestimation of SAP during normo- and hypertension, the oscillometric monitor yielded reliable and easily obtainable blood pressure measurements in anesthetized cats.  相似文献   

19.
The precision and accuracy of an indirect oscillometric blood pressure measurement technique (Dinamap 8100) was assessed in 11 anesthetized Beagle dogs weighing 8 to 11.5 kg. Direct blood pressure measurements were made by catheterization of the lingual artery, and simultaneous indirect measurements were determined by placing a cuff over the median artery (midradial area). Blood pressure measurements at 2 different planes of anesthesia (light and deep) were recorded in triplicate. At a light plane of anesthesia, the Dinamap 8100 underestimated diastolic and mean arterial pressure, and at a deep anesthetic plane overestimated systolic pressure. The indirect technique had good repeatability of systolic pressures. Regression analysis for the 2 techniques showed excellent correlation (r = 0.93). The results indicate that the indirect oscillometric blood pressure measurement technique provides a good estimate of systolic, diastolic, and mean arterial pressure in dogs weighing 8-11.5 kg.  相似文献   

20.
Objective —To determine the accuracy of three indirect blood pressure monitoring techniques (oscillometric technique [OS], Doppler [DOP], and optical plethysmography [OP] [blood pressure determined with a pulse oximeter waveform]) when compared with direct arterial pressure measurement in cats. Study Design —Prospective study. Animal Population —Eight healthy (five female, three male), domestic short-hair cats, weighing 3.5 ± 0.8 kg Methods —Cats were anesthetized with isoflurane. The inspired concentration of isoflurane was adjusted to produce mild hypotension (80 to 100 mm Hg direct systolic), moderate hypotension (60 to 80 mm Hg direct systolic), and severe hypotension (<60 mm Hg direct systolic). Indirect pressure measurements were obtained from the thoracic limb and compared with concurrent direct measurement using regression analysis and a modification of Bland and Altman's technique. Results —All three techniques underestimated systolic pressure. OS produced the best prediction of systolic pressure with a bias ± precision of -15.9 ± 8.1 mm Hg. DOP and OP were relatively inaccurate with a bias ± precision of -25 ± 7.4 mm Hg and -25 ± 7.5 mm Hg. All three techniques correlated well with direct pressure with r values of 0.81, 0.88, and 0.88 for OS, DOP, and OP. DOP and OP provided an accurate prediction of direct mean arterial pressure with a bias ± precision of -0.8 ± 6 mm Hg and 0.6 ± 5.5 mm Hg. Correlation was good between DOP and mean arterial pressure with r = 0.89. Correlation was also good between OP and mean arterial pressure with r = 0.90. Conclusions —OS provided the most accurate prediction of direct systolic pressure. DOP and OP provided a good prediction of mean arterial pressure in the cat. Clinical Relevance —All three of these techniques are useful for detecting trends. Direct monitoring of blood pressure should be considered if accurate blood pressure measurement is required.  相似文献   