排序方式: 共有83条查询结果,搜索用时 15 毫秒
61.
Ann P. Bosiack DVM F. A. Mann DVM MS DACVS DACVECC John R. Dodam DVM PhD DACVA Colette C. Wagner‐Mann MA DVM PhD Keith R. Branson DVM MS DACVA 《Journal of Veterinary Emergency and Critical Care》2010,20(2):207-215
Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP. 相似文献
62.
Sara Zaldivar‐Lopez DVM MS Hope K. Chisnell DVM C. Guillermo Couto DVM DACVIM Nicole Westendorf‐Stingle RVT Liliana M. Marin DVM Maria C. Iazbik DVM Edward S. Cooper VMD MS DACVECC Maxey L. Wellman DVM MS PhD DACVP William W. Muir III DVM MS PhD DACVA DACVECC 《Journal of Veterinary Emergency and Critical Care》2011,21(1):24-28
Objective – The purposes of this study were to evaluate the oxygen affinity of hemoglobin (Hb) in healthy retired racing Greyhounds via cooximetry, and to establish reference intervals for blood gases and cooximetry in this breed. Design – Prospective clinical study. Setting – University Teaching Hospital. Animals – Fifty‐seven Greyhounds and 30 non‐Greyhound dogs. Interventions – Venous blood samples were collected from the jugular vein and placed into heparinized tubes. The samples were analyzed within 30 minutes of collection using a blood gas analyzer equipped with a cooximeter. Measurements and Main Results – Greyhounds had significantly higher pH, PO2, oxygen saturation, oxyhemoglobin, total Hb, oxygen content, and oxygen capacity and significantly lower deoxyhemoglobin and P50 when compared with non‐Greyhound dogs. Conclusion – These findings support the fact that this breed is able to carry a higher concentration of total oxygen in the blood. As reported previously, this breed also has lower P50 and, therefore, high oxygen affinity. In light of recent findings suggesting that in certain tissues a high affinity for oxygen is beneficial, this adaptation may be of benefit during strenuous exercise. 相似文献
63.
64.
65.
66.
67.
Yvette S. Nout DVM Kevin T.T. Corley BSc BVM&S PhD DACVIM MRCVS Lydia L. Donaldson VMD PhD DACVA Martin O. Furr DVM PhD DACVIM 《Journal of Veterinary Emergency and Critical Care》2002,12(2):75-80
Objective: To investigate the agreement between indirect oscillometric and direct blood pressure measurement in the equine neonate. Design: Prospective observational study. Setting: University Veterinary Teaching Hospital. Animals: Ten crossbred foals of 30–46 hours of age. Interventions: Six animals (Group 1) were anesthetized. Four animals (Group 2) were restrained on a mat. All animals were instrumented with a catheter in the greater metatarsal artery and an oscillometric blood pressure cuff over the coccygeal artery. Blood pressure was varied with dobutamine, phenylephrine, nitroprusside, and increased depth of anesthesia (Group 1) or dopamine (Group 2). Measurements and main results: Simultaneous direct and indirect blood pressure measurements were obtained from the greater metatarsal artery and the coccygeal artery, respectively. There was good agreement between the 2 methods for mean and diastolic blood pressures in both groups, but not for systolic pressure. The agreement was best in mean blood pressure of anesthetized foals (mean bias –1.07; limits of agreement – 9.39, 7.25 mmHg). Conclusions: Indirect oscillometry appears to be an acceptable method for measuring mean arterial blood pressure in both anesthetized and conscious neonatal foals, and may be a valid method of monitoring critically ill foals. 相似文献
68.
Tanya L. Tag DVM Thomas K. Day DVM MS DACVA DACVECC 《Journal of Veterinary Emergency and Critical Care》2008,18(1):61-67
Objective: To determine if electrocardiogram (ECG) changes induced by hyperkalemia in clinical patients correspond with previously reported changes in experimental animals. Design: Prospective clinical study. Setting: Two private practice 24‐hour emergency and critical care facilities. Animals: Fifteen dogs and 22 cats with serum potassium levels >5.5 mEq/L. Interventions: None. Measurements: The following data were collected when hyperkalemia was documented: ECG (n=37), sodium and chloride (mEq/L) (n=35), total magnesium (mg/dL) (n=18), total calcium (mg/dL) (n=30), and venous pH (n=18). Animals were divided into five groups based on severity of hyperkalemia and ECG interpretation included rate, rhythm and P‐QRS‐T evaluation. Main Results: Twenty‐two of 37 (59%) of the ECGs were normal or revealed abnormalities that have not been previously described in conjunction with hyperkalemia. In dogs, there was no correlation (r=0) between potassium blood levels and heart rate (n=15). There was weak correlation (r=0.40; P=0.06) between potassium blood levels and heart rate in cats (n=22). The correlation was stronger (r=0.64; P<0.05) when data were compared in cats with serum potassium level >8.5 mEq/L (Groups 4 and Group 5; n=11). Conclusions: ECGs obtained from ill dogs and cats with hyperkalemia are inconsistent with ECGs from experimentally induced hyperkalemia. It is difficult to determine the clinical relevance of heart rate differences between cats with serum potassium levels >8.5 mEq/L and animals with experimentally induced hyperkalemia; this may be due to the presence of other biochemical abnormalities in diseased animals. 相似文献
69.
Amy L. Butler DVM MS Vicki L. Campbell DVM DACVA DACVECC Ann E. Wagner DVM DACVA DACVP Cassidy D. Sedacca DVM Timothy B. Hackett DVM MS DACVECC 《Journal of Veterinary Emergency and Critical Care》2008,18(3):246-257
Objective: Compare cardiac index (CI) and oxygen delivery index (DO2I) in conscious, critically ill dogs to control dogs; evaluate the association of CI and DO2I with outcome. Design: Prospective non‐randomized clinical study. Setting: Veterinary teaching hospital. Animals: Eighteen client‐owned dogs with systemic inflammatory response syndrome (SIRS) and 8 healthy control dogs. Measurements and Main Results: CI of dogs with SIRS was measured using lithium dilution at times 0, 4, 8, 16, and 24 hours. Data collected included physical exam, arterial blood gas (ABG) and hemoximetry. CI of control dogs was measured 3 times with 1 measurement of ABG. Mean CI ± SE in SIRS patients was 3.32 ± 0.95 L/min/m2; lower than controls at 4.18 ± 0.22 L/min/m2 (P<0.001). Mean DO2I ± SE in SIRS patients was 412.91 ± 156.67 mL O2/min/m2; lower than controls at 785.24 ± 45.99 mL O2/min/m2 (P<0.001). There was no difference in CI (P=0.49) or DO2I (P=0.51) for dogs that survived to discharge versus those that did not. There was no difference in mean CI (P=0.97) or DO2I (P=0.50) of survivors versus non‐survivors for 28‐day survival. Survivors had lower blood glucose (P=0.03) and serum lactate concentrations (P=0.04) than non‐survivors. Conclusions: CI and DO2I in conscious dogs with SIRS were lower than control dogs, which differs from theories that dogs with SIRS are in a high cardiac output state. CI and DO2I were not significantly different between survivors and non‐survivors. Similar to previous studies, lactate and glucose concentrations of survivors were lower than non‐survivors. 相似文献
70.
Anticoagulant effects of inhaled unfractionated heparin in the dog as determined by partial thromboplastin time and factor Xa activity 下载免费PDF全文