首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   78篇
  免费   5篇
畜牧兽医   83篇
  2020年   2篇
  2017年   2篇
  2016年   3篇
  2014年   3篇
  2013年   5篇
  2012年   9篇
  2011年   7篇
  2010年   6篇
  2009年   9篇
  2008年   4篇
  2007年   6篇
  2006年   8篇
  2005年   5篇
  2004年   3篇
  2003年   2篇
  2002年   5篇
  1999年   1篇
  1997年   1篇
  1996年   1篇
  1993年   1篇
排序方式: 共有83条查询结果,搜索用时 15 毫秒
61.
Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.  相似文献   
62.
Objective – The purposes of this study were to evaluate the oxygen affinity of hemoglobin (Hb) in healthy retired racing Greyhounds via cooximetry, and to establish reference intervals for blood gases and cooximetry in this breed. Design – Prospective clinical study. Setting – University Teaching Hospital. Animals – Fifty‐seven Greyhounds and 30 non‐Greyhound dogs. Interventions – Venous blood samples were collected from the jugular vein and placed into heparinized tubes. The samples were analyzed within 30 minutes of collection using a blood gas analyzer equipped with a cooximeter. Measurements and Main Results – Greyhounds had significantly higher pH, PO2, oxygen saturation, oxyhemoglobin, total Hb, oxygen content, and oxygen capacity and significantly lower deoxyhemoglobin and P50 when compared with non‐Greyhound dogs. Conclusion – These findings support the fact that this breed is able to carry a higher concentration of total oxygen in the blood. As reported previously, this breed also has lower P50 and, therefore, high oxygen affinity. In light of recent findings suggesting that in certain tissues a high affinity for oxygen is beneficial, this adaptation may be of benefit during strenuous exercise.  相似文献   
63.
64.
65.
66.
67.
Objective: To investigate the agreement between indirect oscillometric and direct blood pressure measurement in the equine neonate. Design: Prospective observational study. Setting: University Veterinary Teaching Hospital. Animals: Ten crossbred foals of 30–46 hours of age. Interventions: Six animals (Group 1) were anesthetized. Four animals (Group 2) were restrained on a mat. All animals were instrumented with a catheter in the greater metatarsal artery and an oscillometric blood pressure cuff over the coccygeal artery. Blood pressure was varied with dobutamine, phenylephrine, nitroprusside, and increased depth of anesthesia (Group 1) or dopamine (Group 2). Measurements and main results: Simultaneous direct and indirect blood pressure measurements were obtained from the greater metatarsal artery and the coccygeal artery, respectively. There was good agreement between the 2 methods for mean and diastolic blood pressures in both groups, but not for systolic pressure. The agreement was best in mean blood pressure of anesthetized foals (mean bias –1.07; limits of agreement – 9.39, 7.25 mmHg). Conclusions: Indirect oscillometry appears to be an acceptable method for measuring mean arterial blood pressure in both anesthetized and conscious neonatal foals, and may be a valid method of monitoring critically ill foals.  相似文献   
68.
Objective: To determine if electrocardiogram (ECG) changes induced by hyperkalemia in clinical patients correspond with previously reported changes in experimental animals. Design: Prospective clinical study. Setting: Two private practice 24‐hour emergency and critical care facilities. Animals: Fifteen dogs and 22 cats with serum potassium levels >5.5 mEq/L. Interventions: None. Measurements: The following data were collected when hyperkalemia was documented: ECG (n=37), sodium and chloride (mEq/L) (n=35), total magnesium (mg/dL) (n=18), total calcium (mg/dL) (n=30), and venous pH (n=18). Animals were divided into five groups based on severity of hyperkalemia and ECG interpretation included rate, rhythm and P‐QRS‐T evaluation. Main Results: Twenty‐two of 37 (59%) of the ECGs were normal or revealed abnormalities that have not been previously described in conjunction with hyperkalemia. In dogs, there was no correlation (r=0) between potassium blood levels and heart rate (n=15). There was weak correlation (r=0.40; P=0.06) between potassium blood levels and heart rate in cats (n=22). The correlation was stronger (r=0.64; P<0.05) when data were compared in cats with serum potassium level >8.5 mEq/L (Groups 4 and Group 5; n=11). Conclusions: ECGs obtained from ill dogs and cats with hyperkalemia are inconsistent with ECGs from experimentally induced hyperkalemia. It is difficult to determine the clinical relevance of heart rate differences between cats with serum potassium levels >8.5 mEq/L and animals with experimentally induced hyperkalemia; this may be due to the presence of other biochemical abnormalities in diseased animals.  相似文献   
69.
Objective: Compare cardiac index (CI) and oxygen delivery index (DO2I) in conscious, critically ill dogs to control dogs; evaluate the association of CI and DO2I with outcome. Design: Prospective non‐randomized clinical study. Setting: Veterinary teaching hospital. Animals: Eighteen client‐owned dogs with systemic inflammatory response syndrome (SIRS) and 8 healthy control dogs. Measurements and Main Results: CI of dogs with SIRS was measured using lithium dilution at times 0, 4, 8, 16, and 24 hours. Data collected included physical exam, arterial blood gas (ABG) and hemoximetry. CI of control dogs was measured 3 times with 1 measurement of ABG. Mean CI ± SE in SIRS patients was 3.32 ± 0.95 L/min/m2; lower than controls at 4.18 ± 0.22 L/min/m2 (P<0.001). Mean DO2I ± SE in SIRS patients was 412.91 ± 156.67 mL O2/min/m2; lower than controls at 785.24 ± 45.99 mL O2/min/m2 (P<0.001). There was no difference in CI (P=0.49) or DO2I (P=0.51) for dogs that survived to discharge versus those that did not. There was no difference in mean CI (P=0.97) or DO2I (P=0.50) of survivors versus non‐survivors for 28‐day survival. Survivors had lower blood glucose (P=0.03) and serum lactate concentrations (P=0.04) than non‐survivors. Conclusions: CI and DO2I in conscious dogs with SIRS were lower than control dogs, which differs from theories that dogs with SIRS are in a high cardiac output state. CI and DO2I were not significantly different between survivors and non‐survivors. Similar to previous studies, lactate and glucose concentrations of survivors were lower than non‐survivors.  相似文献   
70.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号